resume samples for freshers electrical engineers free download

handbook for electrical engineers hu (2)

handbook for electrical engineers hu (2)

Ngày tải lên : 21/03/2014, 12:12
... case. 3.1.8 Instrument Transformers The material that follows is a brief summary of information on instrument transformers as measure- ment elements. For more extensive information, consult American ... instrument transformers, and auxiliary devices. Further detailed information may be found in the Handbook for Electric Metermen, Edison Electric Institute. The practical unit of electrical energy ... level. Both excitation and test windings on the sample should be uniformly distributed. Permeameters are used for small samples and for “hard” magnetic materials which cannot be dri- ven to a sufficiently...
  • 66
  • 378
  • 0
handbook for electrical engineers hu (3)

handbook for electrical engineers hu (3)

Ngày tải lên : 21/03/2014, 12:12
... unity for vacuum to slightly greater than unity for gases at atmospheric pressure, 2 to 8 for common insulating solids and liquids, 35 for ethyl alcohol and 91 for pure water, and 1000 to 10,000 for ... Fire-refined copper is a lower-purity grade intended for alloying or for fabrication into products for mechanical purposes; it is not intended for electrical purposes. Casting copper is the grade ... industry, but for this purpose it is obtained in the form of ferrosilicon, which is a coarse granulated or broken product. It is very useful as an alloying element in steel for electrical sheets...
  • 110
  • 473
  • 0
handbook for electrical engineers hu (4)

handbook for electrical engineers hu (4)

Ngày tải lên : 21/03/2014, 12:12
... produced for further fission action. For a 1300-MW (electrical) light-water nuclear plant, a representative core assembly might involve 241 fuel assemblies each weighing approxi- mately 660 kg, for ... The uranium would be cleaned up in preparation for reuse. For each 1200-lb assembly, there would be only around 35 lb of fission product waste. For 60 assemblies discharged per reactor per year, ... the average lifetime of the neutrons. Substituting for k inf and D gives Substituting 1/ for ␯Σ ␣ (1 ϩ L 2 B 2 ) gives The balance equation for the delayed group is (5-14) Substituting gives and...
  • 114
  • 360
  • 0
handbook for electrical engineers hu (5)

handbook for electrical engineers hu (5)

Ngày tải lên : 21/03/2014, 12:12
... HANDBOOK FOR ELECTRICAL ENGINEERS PRIME MOVERS 6-17 to h 1 − h 2 minus the small pump work h 4 – h 3 ϭ␯ 3 (P 4 – P 3 )/J required, and the heat added to the cycle is equal to h 1 – h 4 . Therefore (6-4) ... stainless steels. The rotor may be a single forging, fabricated from a shaft and separate wheels, or constructed of forged elements welded together. The buckets forming the rotating portion of the steam ... a high-pressure hydraulic system to provide the force required. FIGURE 6-7 Mechanical governor for small turbines. Beaty_Sec06.qxd 17/7/06 8:31 PM Page 6-11 Downloaded from Digital Engineering Library...
  • 28
  • 439
  • 0
handbook for electrical engineers hu (6)

handbook for electrical engineers hu (6)

Ngày tải lên : 21/03/2014, 12:12
... number of slots per pole per phase g ϭ electrical angle between slots q s ϭ electrical angle of skew Here, the relevant angles are stated in electrical terms. The electrical angle is p times the physical angle. ... construction. The rotor body for a salient-pole machine may be a solid forging or assembly of heavy steel plates, for high-speed designs, or a spider-and-rim assembly for low-speed designs. The ... transport loss. 7.9 TESTING OF AC GENERATORS Tests are performed on generators to establish conformance with projected performance and dynamic performance parameters. Details of such tests are contained...
  • 42
  • 431
  • 0
handbook for electrical engineers hu (7)

handbook for electrical engineers hu (7)

Ngày tải lên : 21/03/2014, 12:12
... poles. The oiling system for the bearings should be checked and the oil rings tested for freedom. The entire machine, particularly its air gaps, should be inspected for foreign material. Running ... coil equal to 1 V for a change of 10 8 linkages/s (Mx/s) for each turn of the coil, or E ϭ (⌬fT ϫ 10 –8 )/t V. If the flux lines are deformed by the motion of the coil conductor before they are broken, ... Institute (ANSI) C50.4 for dc machines includes lists of recommended tests for dc generators and motors. The IEEE Test Code for dc machines covers recommended methods to be used for these tests. 8.14...
  • 42
  • 503
  • 0
handbook for electrical engineers hu (8)

handbook for electrical engineers hu (8)

Ngày tải lên : 21/03/2014, 12:12
... website. Source: STANDARD HANDBOOK FOR ELECTRICAL ENGINEERS HYDROELECTRIC POWER GENERATION 9-21 If the combined turbine-generator efficiency is to be calculated, the formula may be changed to where ... turbine for a given hydroelectric powerplant, it is important to consider the efficiency performance of the various types of turbines available for the head contemplated. Not only is this true for ... spillway, etc. Bulkhead gate. A gate used either for temporary closure of a channel or conduit before dewater- ing it for inspection or maintenance or for closure against flowing water. Bulkhead gates...
  • 28
  • 416
  • 0
handbook for electrical engineers hu (9)

handbook for electrical engineers hu (9)

Ngày tải lên : 21/03/2014, 12:12
... correction of 0.4% of rated kVA for self-cooled transformers or 0.5% of rated kVA for forced-air-cooled or forced-oil-cooled transformers for each 330 ft of additional altitude above 3300 ft ... as for a self-cooled transformer. Operation at high altitude increases the effective oil rise of air-cooled transformers. ANSI C57 provides for a compensating correction of 0.4% of rated kVA for ... tables for normal consumption of life and for moderate sacrifice of life are documented in ANSI/IEEE C57.92 for power transformers. Information is provided for situations 10-48 SECTION TEN FIGURE...
  • 152
  • 439
  • 0
handbook for electrical engineers hu (10)

handbook for electrical engineers hu (10)

Ngày tải lên : 21/03/2014, 12:12
... manifested in mechanical, electrical, chemical, and thermal forms—the latter being a spe- cial form of mechanical energy. Energy may be converted from any of these forms to any other form by one or more ... useful for planning pur- poses, but being able to forecast the wind accurately for one or two days could provide a significant economic benefit, allowing utility engineers to plan ahead for wind ... of the PV market. For the 2,000 million people in the developing world who currently have no access to basic electrical services, PV presents the opportunity for a giant leap forward and a much...
  • 130
  • 403
  • 0
handbook for electrical engineers hu (11)

handbook for electrical engineers hu (11)

Ngày tải lên : 21/03/2014, 12:12
... STANDARD HANDBOOK FOR ELECTRICAL ENGINEERS used to depict the use of each type of fuel. Coal, for example, would include track networks for train transportation, river networks for barge transportation, ... Heat, Motion, Information FIGURE 12-2 Electric supply chain model. Generation Stepup transformer National grid 400 kV – 275 kV Stepdown transformer Industry 11 kV Substation transformer 11 kV Distribution ... availability. The spot market is for immediate delivery of the commodity. The forward market is for the near–term delivery of the commodity. The future markets are for the financial hedging of the...
  • 14
  • 336
  • 0
handbook for electrical engineers hu (12)

handbook for electrical engineers hu (12)

Ngày tải lên : 21/03/2014, 12:12
... of equipment that may not work well for its application. By leasing, the lessee gets a chance to work with the equipment and see if it performs as expected—before spending large amounts of investment ... having cash available to use for whatever investment opportunity may appear in the future. Before one person will lend money to another, the interest earned must compensate the lender for the unavailability ... installation, and the lessee party pays for its use. Since the lessee must pay enough profit to the lessor for the lessor to be willing to install the property for the lessee’s use, this arrangement...
  • 18
  • 293
  • 0
handbook for electrical engineers hu (13)

handbook for electrical engineers hu (13)

Ngày tải lên : 21/03/2014, 12:12
... HANDBOOK FOR ELECTRICAL ENGINEERS silica. Insulators of high-grade electrical porcelain of the proper chemical composition free from laminations, holes, and cooling stresses have been available for ... dB(A) 2 ഛ d ഛ 6 N p ϭ number of phases For each phase, the L 5 noise level is given by (14-27) with AN 0 ϭ 75.2 for n Ͻ 3 ϭ 67.9 for n Ն 3 K 1 ϭ 7.5 for n ϭ 1 ϭ 2.6 for n ϭ 2 AN 5 ϭ Ϫ 665 g ϩ 20 log ... at a specific conductor size, where installed cost forces the PWRR higher for large conductors and the cost of losses forces the PWRR higher for smaller conductors. This is conceptualized in Fig....
  • 142
  • 312
  • 0
handbook for electrical engineers hu (14)

handbook for electrical engineers hu (14)

Ngày tải lên : 21/03/2014, 12:12
... are significantly lower for HVDC lines than for EHV ac lines but are more sensitive to altitude effects. Switching surges are significantly lower for HVDC lines than for EHV ac lines. Switching ... through ac phase reactors and power transformers. Harmonic filters are located between the phase reactors and power transformers. Therefore, the transformers are exposed to no dc voltage stresses ... website. Source: STANDARD HANDBOOK FOR ELECTRICAL ENGINEERS DC-Capacitors. The primary objective of the valve dc side capacitor is to provide a low-inductance path for the turn-off switching currents...
  • 36
  • 370
  • 0
handbook for electrical engineers hu (15)

handbook for electrical engineers hu (15)

Ngày tải lên : 21/03/2014, 12:12
... power system they serve. For example, a unique load forecast model is developed for each case. Load Forecast. This program forecasts hourly loads 1 to 7 days in advance. Load-forecasting methods are ... maintaining frequency, which is uniform among areas, but are individu- ally responsible for maintaining each area’s scheduled net interchange. The formula for this is where the summation is over ... contribution for phase relays or ground-fault contribution for ground relays or phase relays) for a fault at B and by the influence on the measuring unit of the dc component in the fault current. For...
  • 50
  • 304
  • 0
handbook for electrical engineers (16)

handbook for electrical engineers (16)

Ngày tải lên : 21/03/2014, 12:12
... Institute of Electrical and Electronics Engineers Guide for Loading Mineral-Oil-Immersed Transformers. NEMA Publ. TR98-1964 contains corresponding recommendations for loading power trans- formers ... 105 effect on insulation life and transformer life. For recurring loads, such as the daily load cycles, the transformer would be operated for normal life expectancy. For emergencies, either planned ... transformers. The tem- perature of the top oil should never exceed 100°C. The maximum hot-spot winding temperature should not exceed 150°C for 55°C rise transformers or 180°C for 65°C rise transformers....
  • 52
  • 354
  • 1