... parameters of 10 EURASIP Journal on Advances in Signal Processing CEM (1) Load the MAT file from SOFA pd MAT FILE (2) Load a WAV file as excitation signal pd WAV EXCITATION load load trigger start ... propose a new approach to modal analysisusing automatic voxelization of a surface model and computation of the finite elements parameters, based on the distribution of material in each cell Our goal ... Modal Analysis The method for FEM model [17] is adapted from realtime deformation to modal analysis In particular, the modal parameters are extracted in a preprocessing step by solving the equation...
... 113 Average classification accuracy on body language category 114 Average classification accuracy on speaker’s attention concept114 Average classification accuracy on audience’s engagement ... computational component [Hummon and Fararo, 1995] Advanced computational systems enable a variety of techniques to collect, manage and analyze this vast array of information, to address important ... from audio-visual data In addition, human attraction estimation has been investigated in the context of Speed-Dating applications for giving feedback by analyzing behavior [Ranganath, Jurafsky, and...
... 113 Average classification accuracy on body language category 114 Average classification accuracy on speaker’s attention concept114 Average classification accuracy on audience’s engagement ... enable novel and important applications for research in wearable computing The recent and widespread availability of a number of appealing wearable cameras, such as Google Glass and GoPro cameras, ... 2011; Bazzani et al., 2013] 2.2.2 Social Signals for Social Interaction Analysis The problem of machine analysis of human social signals includes two main stages [Vinciarelli, Pantic, and Bourlard,...
... of appropriate non-linear analysis, such as fractal analysis, in place of traditional analyses [1] A strong reason behind this paradigm shift is the acknowledgment of variability in natural systems ... from a fractal pattern may be indicative of a shift towards an unhealthy or less desirable control strategy The analysis of fractal patterns in gait and posture data may serve as an indicator ... Parkinsonian patients (PP), spinocerebellar ataxia (SCA) patients, and healthy participants’ COP were analysed usinga more traditional fractal dimension analysis [13] This method recorded COP data and...
... in rats J Pharm Sci 74:780–782 10) Kielbasa WB, Bauer JA, Fung HL (1999) Analysis of isobutyl nitrite inhalant in rat and human blood: application for pharmacokinetic investigations J Chromatogr ... principle, the sampling, extraction and GC analysis should be made at low temperature, in a gastight state and in a short time This method is applicable to other biomedical specimens and drinks/foods ... containing different concentrations of the analyte are prepared to construct each external calibration curve, consisting of the concentration of an alkyl nitrite on the horizontal axis and peak area...
... GC/MS analysis for DAEMS in serum (a) a total ion chromatogram (TIC) and a mass chromatogram; (b) an EI mass spectrum of DAEMS; (c) a CI mass spectrum of DAEMS Poisoning case, and toxic and fatal ... ratio of DAEMS to IS on the vertical axis and DAEMS concentration on the horizontal axis A peak area ratio obtained from a test specimen is applied to the calibration curve to calculate a DAEMS concentration ... Preparation, stability and quantitative analysis by gas chromatography and gas chromatography-electron impact mass spectrometry of tert-butyldimethylsilyl derivatives of some alkylphosphonic and...
... 188 Cannabinoids and their metabolites GC analysis of cannabinoids in plant specimensa Reagents and their preparation • • • Extraction and purification of cannabinoids [3]: Cannabis sativa L is ... with cannabinoid concentration on the horizontal axis and with peak area ratio of a cannabinoid to IS on the vertical axis GC analysis of cannabinoids in plant specimens ⊡ Figure 2.2 Gas chromatogram ... Kagaku 25:321–326 6) Matsunaga T, Nagatomo H, Narimatsu S et al (1993) Studies on identification of cannabis seeds I: Qualitative and quantitative analysis of cannabinoids in cannabis seeds Jpn J...
... Morphine and its analogues 8) Matsubara K, Fukushima S, Akane A et al (1992) Increased urinary morphine, codeine and tetrahydropapaveroline in Parkinsonian patient undergoing L-3,4-dihydroxyphenylalanine ... Qualitative analysis is made by the comparison of the retention time of a peak of a specimen with that of the authentic standard and also by the confirmation of the absence of such a peak in a ... not, an appropriate amount of the above buffer solution is added to it The blank urine and calibration samples are processed in the same way These samples are equally treated according to the above...
... cyanosis headache, dyspnea, tachypnea, tachycardia and hypertension mental derangement, listlessness and metabolic acidosis coma, convulsive attack and hypotension death A poisoning case [4] An ... layer is injected into GC Various known amounts of nitrate and a fixed amount of IS are added to blank specimens and processed in the same way to construct a calibration curve The peak area ratio ... cause of his death was diagnosed as methemoglobinemia The poison causing his methemoglobinemia was analyzed by the present method; it was disclosed that he had ingested nitrate The analytical...
... phase and a cation exchanger phase; the mechanisms are reversed-phase extraction plus cation-exchanging action The LRC reservoir is advantageous, because as much as 10 mL of sample solution can ... Instruction Manual Harbor City, CA, USA 7) Abusada GM, Abukhalaf IK, Alford DD et al (1993) Solid-phase extraction and GC/MS quantitation of cocaine, ecgonine methyl ester, benzoyl-ecgonine, and cocaethylene ... blood, and plasma J Anal Toxicol 17:353–358 8) Crouch DJ, Alburges ME, Spanbauer AC et al (1995) Analysis of cocaine and its metabolites from biological specimens using solid-phase extraction and...
... about A 10-mL volume of ethanol and 10 mL distilled water are passed through a Sep-Pak C18 cartridge usinga 10-mL volume glass syringe to activate the cartridge at a flow rate not faster than ... chromatography Pharmazie 46:464–465 8) Seno H, Kumazawa T, Ishii A et al (2000) Determination of pentazocine in human whole blood and urine by gas chromatography/surface ionization organic mass ... grand mal She was sent to an emergency room, but still showed general cyanosis, convulsions and severe tachycardia Because of her irregular spontaneous respiration, endotracheal intubation was...
... extract is evaporated to dryness; the residue is dissolved in a small amount of methanol to be subjected to further analysis TLC analysis Analytical conditions TLC plate: a usual silica gel plate, ... ion appears as the base peak Fragment peaks can be observed at m/z 221, 207, 181 and 167 The fragmentation pathways are shown in > Fig 6.2 The confirmation of LSD should be made with each mass ... Standard Methods of Chemical Analysis in Poisoning – With Commentary – Nanzando, Tokyo, p 43 and p 151 (in Japanese) 3) Cody JT (2000) Hallucinogens In: Bogusz MJ (ed) Handbook of Analytical...
... disseminated intravascular coagulation and death [19, 20] A detailed review by Kalant [16] revealed that 87 MDAs-related fatalities were associated with hyperpyrexia, rhabdomyolysis, intravascular ... altered mental status altration in muscle tone/activity automatic instability hyperthermia diarrhea hyponatremia seizures rhabdomyolysis acute renal fairure disseminated intravascular coagulation ... M et al (1991) Determination of methamphetamine and amphetamine in urine by headspace gas chromatography/mass spectrometry Anal Sci 7:19–22 25) Shima N, Kamata T, Nishikawa M et al Examination...
... fluids by headspace solid-phase microextraction (SPME) Chromatographia 43:331–333 14) Nakahara Y, Takahashi K, Sakamoto T et al (1997) Hair analysis for drugs of abuse X VII Simultaneous detection ... verbally; the levels of serum creatinin kinase and aspartate aminotransferase were more than 100-times the normal limits On hospital day 2, he became rigid, diaphoretic and had a temperature reaching ... γ-Hydroxybutyrate is a weak agonist at recombinant GABAB receptors Neuropharmacology 38:1667–1673 9) Blumenfeld M, Suntay RG, Harmel MH (1962) Sodium gamma-hydroxybutyric acid: a new anesthetic adjuvant Anesth...
... Mitsubishi Welpharma, Osaka, Japan; that of flupentixol by Takeda Chem Ind Ltd., Osaka, Japan; that of thioproperazine by Shionogi & Co., Ltd., Osaka, Japan; that of thiethylperazine by Sandoz, Basel, ... of a calibration curve for a target compound by LC/MS is essentially similar to that for GC/MS At least vials containing various concentrations of a target compound are prepared for a calibration ... Pharmaceutical Society of Japan (ed) (1992) Standard Methods of Chemical Analysis in Poisoning – With Commentary, 4th edn Nanzando, Tokyo, pp 150–158 (in Japanese) 7) Hattori H, Yamamoto S, Iwata...
... to draw a calibration curve A peak area ratio of a test specimen is applied to the calibration curve to calculate its concentration Assessment of the method The butyrophenone drugs analyzable ... Medical Drugs Van Medical, Tokyo, p 56 (in Japanese) 19) Uges DRA (1997) Blood level data In: Brandenberger H, Maes RAA (eds) Analytical Toxicology for Clinical, Forensic and Pharmaceutical Chemists ... their surfaces, causing variation of results References 1) Seno H, Suzuki O, Kumazawa T et al (1989) Rapid isolation with Sep-Pak C18 cartridges and wide-bore capillary gas chromatography of some...
... antidepressants can Poisoning cases, and toxic and fatal concentrations ⊡ Table 3.2 RI values and mass spectra of tricyclic and tetracyclic antidepressants Name amitriptyline amoxapine carbamazepine ... 52:1190–1195 (in Japanese) 3) Tanaka E, Terada M, Nakamura T et al (1997) Forensic analysis of eleven cyclic antidepressants in human biological samples usinga new reversed-phase chromatographic column ... A, Watanabe T, Yashiki M et al (1998) Simple analysis of tetracyclic antidepressants in blood using headspace-solid phase microextraction and GC/MS J Anal Toxicol 22:396–400 6) Okada K, Kimura...
... thin-layer chromatography J Anal Toxicol 15:123–125 5) Tanaka E, Nakamura T, Nagashima A et al (2001) Determination of plasma bromvalerylurea and its main metabolite by a simple high-performance ... (Aldrich, Milwaukee, WI, USA) and an equimolar amount of urea are placed in a 100 mL volume eggplant-shaped glass flask and warmed in a water bath to form a soft clay After warm distilled water ... – A case of bromvalerylurea intoxication – Jpn J Legal Med 41:452–456 (in Japanese with an English abstract) 16) Kiyota K, Maekawa K, Nishihara K et al (1997) Significance of bromvalerylurea and...