... continuous-media data. For multimedia data mining, storage and search techniques need to be integratedwith standard datamining methods. Promising approaches include the construction ofmultimedia data ... inte-grated with the mining module, depending on the implementation of the data mining method used. For efficient data mining, it is highly recommended to push Data Mining: Concepts and Techniques Second ... Advanced database systems include object-relational databases and specific application-oriented databases, such as spatial databases, time-series databases,text databases, and multimedia databases....
... temperature is needed. This can be approximated by: 82 Design of GAS-HANDLING Systems and Facilities(lex'i continued from page 79}FIRED HEATERDirect-fired combustion equipment ... (F), and a corrected LMTD as calculated from Equation 3-1.Next, a tube diameter and tube length are chosen. The number of tubesrequired is calculated by:where N = required ... GAS-HANDLING Systems and Facilitiesmay be used if desired. It is important to select the gasket materials to becompatible with the fluids and temperatures being handled.AERIAL...
... hydrocarbons and is normally vented to atmosphere ata safe location. If necessary, the water vapor can be condensed in an aeri-al cooler and routed to the produced water treating ... theglycol/water phase are separated in a three-phase separator. The lean gly-col from the bottom of the condenser is cooled, pumped, cooled again, and fed to the contactor.Choice ... acid with the condensed water.The capacity of a gas stream for holding water vapor is reduced as thestream is compressed or cooled. Thus, water can be removed from thegas stream...
... cooled the saturation level ofwater vapor is lowered significantly and water is condensed. The water isseparated in the regeneration gas separator and the cool, saturated ... increased, the water capturedwithin the pores of the desiccant turns to steam and is absorbed by thenatural gas. This gas leaves the top of the tower and is cooled by theregeneration ... beendehydrated. If wet gas is used, it must be dehydrated after being used ascooling gas. A, hot tower will not sufficiently dehydrate the gas.The switching of the beds is controlled...
... weight, and speed squared. The totalload imposed on the crosshead pin and bushing is the sum of the gas load and the inertia load and is referred to as the "combined rod ... the perceived advantgaes of non-cooled cylinders are simplified cylin-der designs that reduce cost and improve efficiency, reduced initial sys-tem costs due to reductions in ... system, improved valveaccessibility, and reduced weight.Many manufacturers, users, and compressor applications still requirethat compressor cylinders be supplied with liquid-cooled cylinders....