and often undergo chemical modifications of their base moieties as modified nucleotides may have deleterious effects on cells

09 Physical and Chemical Characteristics of DDGS revisions.

09 Physical and Chemical Characteristics of DDGS revisions.

Ngày tải lên : 08/08/2012, 10:03
... possible of syrup was added to the mash before drying. Actual rates of solubles addition to the mash were 0, 12, 25 and 42 gallons/minute. As shown in Table 1, increasing solubles addition rate ... of ingredient segregation during transport and handling – particle and ingredient segregation (separation) occurs when particles of different sizes and bulk densities are blended together and ... 2006).Other factors that may affect flowability include chemical constituents, protein, fat, starch and carbohydrate levels as well as the addition of flow agents. Under certain conditions, DDGS can exhibit...
  • 8
  • 748
  • 0
CHEMICAL ANALYSIS OF WATER AND WASTEWATER

CHEMICAL ANALYSIS OF WATER AND WASTEWATER

Ngày tải lên : 23/07/2013, 20:57
... steadily increasing their use in water analysis. Based upon size and physical configuration, at least three categories of such devices are available. One of these is the conventional solid-phase extractor ... neutralize bases as strong as, or stronger than, carbonate ion, CO 3 2 - + H + → HCO 3 - (24.2.1) or by titration to pH 4.5 to neutralize bases weaker than CO 3 2 - , but as strong as, or stronger ... identification of specific organic pollutants. It depends upon the production of ions by an electrical discharge or chemical process, followed by separation based on the charge-to-mass ratio and measurement...
  • 25
  • 793
  • 0
Tài liệu TREES OF THE NORTHERN UNITED STATES THEIR STUDY, DESCRIPTION AND DETERMINATION FOR THE USE OF SCHOOLS AND PRIVATE STUDENTS doc

Tài liệu TREES OF THE NORTHERN UNITED STATES THEIR STUDY, DESCRIPTION AND DETERMINATION FOR THE USE OF SCHOOLS AND PRIVATE STUDENTS doc

Ngày tải lên : 13/02/2014, 12:20
... determined. As a general thing the leaf has but one blade, as in the Chestnut, Apple, Elm, etc.; yet the Horse-chestnut has 7 blades, the Common Locust often has 21, and a single leaf of the Honey-locust ... petiole is often very short and sometimes wanting. The stipules are often absent, and, even when present, they frequently fall off as soon as the leaves expand; sometimes they are conspicuous. ... Botany as to desire more information concerning the growth and reproduction of plants than can here be given. In Professor Asa Gray's numerous works the additional information desired may...
  • 295
  • 569
  • 0
Tài liệu METHODS FOR ORGANIC CHEMICAL ANALYSIS OF MUNICIPAL AND INDUSTRIAL WASTEWATER ppt

Tài liệu METHODS FOR ORGANIC CHEMICAL ANALYSIS OF MUNICIPAL AND INDUSTRIAL WASTEWATER ppt

Ngày tải lên : 14/02/2014, 03:20
... for one or more measurements of a sample containing a concentration of C, in µg/L S ' = Expected single analyst standard deviation of measurements at an average r concentration found of , ... The width of the retention time window used to make identifications should be based upon measurements of actual retention time variations of standards over the course of a day. Three times the standard ... those of the peaks in standard chromatograms. The width of the retention time window used to make identifications should be based upon measurements of actual retention time variations of standards...
  • 24
  • 762
  • 1
Tài liệu METHODS FOR ORGANIC CHEMICAL ANALYSIS OF MUNICIPAL AND INDUSTRIAL WASTEWATER doc

Tài liệu METHODS FOR ORGANIC CHEMICAL ANALYSIS OF MUNICIPAL AND INDUSTRIAL WASTEWATER doc

Ngày tải lên : 14/02/2014, 03:20
... the secondary dilution standard be prepared at a concentration of 15 µg/mL of each internal standard compound. The addition of 10 µL of this standard to 5.0 mL of sample or calibration standard ... must be at least 25 cm long and have an inside diameter of at least 0.105 in. The trap must be packed to contain 1.0 cm of methyl silicone coated packing (Section 6.5.2) and 23 cm of 2,6-diphenylene ... duplicates may be analyzed to assess the precision of the environmental measurements. When doubt exists over the identification of a peak on the chromatogram, confirmatory techniques such as gas chromatography...
  • 20
  • 536
  • 0
Tài liệu PHYSICAL AND CHEMICAL ASPECTS OF ORGANIC ELECTRONIC doc

Tài liệu PHYSICAL AND CHEMICAL ASPECTS OF ORGANIC ELECTRONIC doc

Ngày tải lên : 16/02/2014, 19:20
... investigations [29, 30]. OFETs and Organic Electronics Organic electronics and the preparation of organic thin films for applications in organic electronics have recently not only been the topic of a ... OFET on Foil Substrates 391 18.3.2.4 Conclusion 392 18.4 Degradation 393 18.5 Conclusion 398 Acknowledgements 399 References 399 19 Influence of Metal Diffusion on the Electronic Properties of ... various aspects of OFETs, in- cluding the synthesis of new materials, preparation and characterisation of or- ganic thin films, characterisation of device properties and the development of new...
  • 733
  • 2.7K
  • 1
Tài liệu The Acquisition of Drugs and Biologics for Chemical and Biological Warfare Defense - Department of Defense Interactions with the Food and Drug Administration doc

Tài liệu The Acquisition of Drugs and Biologics for Chemical and Biological Warfare Defense - Department of Defense Interactions with the Food and Drug Administration doc

Ngày tải lên : 17/02/2014, 11:20
... benefits, and risks of the product in question. FDA may also require, as a condition of approval of an NDA or BLA application, that postmarketing studies be conducted to monitor and confirm the ... representatives of the Centers for Disease Control and Prevention and of the National Institutes of Health as well as academic researchers. FDA usually acts in accord with advisory committee recommendations ... unified commands, and the defense agencies under Contract DASW01-01-C-0004. RAND is a nonprofit institution that helps improve policy and decisionmaking through research and analysis. RAND ® is...
  • 99
  • 600
  • 0
Tài liệu Báo cáo khoa học: Endotoxic activity and chemical structure of lipopolysaccharides from Chlamydia trachomatis serotypes E and L2 and Chlamydophila psittaci 6BC pdf

Tài liệu Báo cáo khoa học: Endotoxic activity and chemical structure of lipopolysaccharides from Chlamydia trachomatis serotypes E and L2 and Chlamydophila psittaci 6BC pdf

Ngày tải lên : 20/02/2014, 23:20
... Isolation of mononuclear cells and granulocytes from human blood. Isolation of monuclear cells by one centrifu- gation, and of granulocytes by combining centrifugation and sedimentation at 1 g. Scand. ... even up to a concentration of 1 lgÆmL )1 (Table 5). In contrast, HEK cells could be activated by LPS of E. coli F515, synthetic lipid A and S. enterica LPSataconcentrationaslowas 1–10 ngÆmL )1 . ... results of these experiments suggested strongly that chlamydial LPS may be dependent on the expression of CD14, as C. trachomatis E LPS was unable to stimulate IL-8 release from HEK control cells...
  • 11
  • 560
  • 0
APPENDIX A TO PART 136 METHODS FOR ORGANIC CHEMICAL ANALYSIS OF MUNICIPAL AND INDUSTRIAL WASTEWATER pot

APPENDIX A TO PART 136 METHODS FOR ORGANIC CHEMICAL ANALYSIS OF MUNICIPAL AND INDUSTRIAL WASTEWATER pot

Ngày tải lên : 05/03/2014, 21:20
... Criteria Mass m/z Abundance criteria 50 15-40% of Mass 95. 75 30-60% of Mass 95. 95 Base Peak, 100% Relative Abundance. 96 5-9% of Mass 95. 173 <2% of Mass 174. 174 >50% of Mass 95. 175 5-9% of ... operation. One of the calibration standards should be at a concentration near, but above, the MDL (Table 1) and the other concentrations should correspond to the expected range of concentrations ... standard deviation of measurements at an average concentration r found of , in µg/L. S' = Expected interlaboratory standard deviation of measurements at an average concentration found of...
  • 27
  • 771
  • 0
APPENDIX A TO PART 136 METHODS FOR ORGANIC CHEMICAL ANALYSIS OF MUNICIPAL AND INDUSTRIAL WASTEWATER: METHOD 604—PHENOLS docx

APPENDIX A TO PART 136 METHODS FOR ORGANIC CHEMICAL ANALYSIS OF MUNICIPAL AND INDUSTRIAL WASTEWATER: METHOD 604—PHENOLS docx

Ngày tải lên : 05/03/2014, 21:20
... for one or more measurements of a sample containing a concentration of C, in µg/L. s ' = Expected single analyst standard deviation of measurements at an average r concentration found of ... those of the peaks in standard chromatograms. The width of the retention time window used to make identifications should be based upon measurements of actual retention time variations of standards ... stock standards to a volumetric flask. To each calibration standard, add a known constant amount of one or more internal standards, and dilute to volume with 2-propanol. One of the standards...
  • 22
  • 686
  • 0
Báo cáo khoa học: Two types of replication protein A in seed plants Characterization of their functions in vitro and in vivo ppt

Báo cáo khoa học: Two types of replication protein A in seed plants Characterization of their functions in vitro and in vivo ppt

Ngày tải lên : 07/03/2014, 21:20
... to function not only in the replication of DNA but also in DNA recombination in the ears. On the other hand, based on the high expression of OsRPA70b in actively dividing tissues [24,25], OsRPA70b may ... characterization of two flap endonuclease-1 homologues in rice. Gene 314, 63–71. 32 Baba A, Hasezawa S & Syono K (1986) Cultivation of rice protoplasts and their transformation mediated by ... the primary function of OsRPA70a and OsRPA70b is to bind DNA, and that this function has been conserved during evolution, even though the secondary functions of these proteins may have diverged. OsRPA70a...
  • 12
  • 588
  • 0
Báo cáo Y học: Tyrosine sulfation and N-glycosylation of human heparin cofactor II from plasma and recombinant Chinese hamster ovary cells and their effects on heparin binding pot

Báo cáo Y học: Tyrosine sulfation and N-glycosylation of human heparin cofactor II from plasma and recombinant Chinese hamster ovary cells and their effects on heparin binding pot

Ngày tải lên : 08/03/2014, 22:20
... Here, we report on the structure of post- translational modifications of plasma-derived and recom- binant human HCII from CHO cells and their effects on heparin binding. MATERIALS AND METHODS Outdated ... recombinant Escherichia coli was bought from Roche Molecular Bio- chemicals. Vibrio cholerae sialidase was from Calbiochem. Stable expression and amplification of HCII in CHO cells Plasmid pWTBI2 was constructed ... containing the same concentration of the glycosylation inhibitor w as added. Three days later, the conditioned medium was harvested and inspected by Western blotting for the presence of HCII as...
  • 12
  • 489
  • 0
APPENDIX A TO PART 136 METHODS FOR ORGANIC CHEMICAL ANALYSIS OF MUNICIPAL AND INDUSTRIAL WASTEWATER: METHOD 605—BENZIDINES pdf

APPENDIX A TO PART 136 METHODS FOR ORGANIC CHEMICAL ANALYSIS OF MUNICIPAL AND INDUSTRIAL WASTEWATER: METHOD 605—BENZIDINES pdf

Ngày tải lên : 14/03/2014, 20:20
... standard chromatograms. The width of the retention time window used to make identifications should be based upon measurements of actual retention time variations of standards over the course of ... for one or more measurements of a sample containing a concentration of C, in µg/L. s '= Expected single analyst standard deviation of measurements at an average r concentration found of , ... constant amount of one or more internal standards, and dilute to volume with mobile phase. One of the standards should be at a concentration near, but above, the MDL and the other concentrations should...
  • 17
  • 778
  • 0
APPENDIX A TO PART 136 METHODS FOR ORGANIC CHEMICAL ANALYSIS OF MUNICIPAL AND INDUSTRIAL WASTEWATER: METHOD 611—HALOETHERS potx

APPENDIX A TO PART 136 METHODS FOR ORGANIC CHEMICAL ANALYSIS OF MUNICIPAL AND INDUSTRIAL WASTEWATER: METHOD 611—HALOETHERS potx

Ngày tải lên : 14/03/2014, 20:20
... for one or more measurements of a sample containing a concentration of C, in µg/L. S ' = Expected single analyst standard deviation of measurements at an average r concentration found of ... interlaboratory standard deviation of measurements at an average concentration found of , in µg/L. C = True value for the concentration, in µg/L. = Average recovery found for measurements of samples containing ... duplicates may be analyzed to assess the precision of the environmental measurements. When doubt exists over the identification of a peak on the chromatogram, confirmatory techniques such as gas chromatography...
  • 19
  • 920
  • 0

Xem thêm