Tài liệu Next Generation Frame 600 mm Products Introduction pptx

26 205 0
Tài liệu Next Generation Frame 600 mm Products Introduction pptx

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

Thông tin tài liệu

10/03 • 100571 600 mm Products 2 www.adc.com • +32-2-712-65-00 • +32-2-712-65-42 2 Next Generation Frame 600 mm Products Introduction Frames ADC’s Next Generation Frame product line has fiber frames designed to fit a variety of termination, splice, and storage applications. Each frame option is designed with an emphasis on superior cable management and ease of use, including features such as ample trough space for cable and jumpers, easy access to connectors, and storage for jumpers. The frame sections are shipped from the factory fully equipped with all cable management hardware including a built-in jumper storage panel. Fiber Termination Blocks (FTB) Fiber Termination Blocks (FTBs) are available with SC, FC, ST ® and E-2000 adapters in block configurations of 48, 72 or 96 positions. Also, 144 position FTBs are available using LX.5 ® and LC adapters. FTBs utilize sliding adapter packs to gain easy access to both the front and rear connectors. There is also a block configuration available to accommodate Mini Value-Added Modules (Mini VAMs) for applications requiring splitters or WDMs. FTBs can be ordered with or without IFC or outside plant cable. Fiber Combination Blocks Blocks (FCB) Fiber Combination Blocks (FCBs) provide termination and on-frame splicing capabilities, all in one block. The block occupies two mounting positions on the frame section. They are available with SC, FC, ST ® and E-2000 adapters in block configurations of 48, 72 or 96 positions. Also, 144 position FCBs are available using LX.5 ® or LC adapters. Features and Benefits Ample Trough Space Reduces jumper pile-up and congestion - Reduces maintenance time due to easy removal and tracing of jumpers - Minimizes risk of microbends or damage to fiber Built-in Jumper Storage Panel Minimizes number of required jumper lengths Maintains fiber bend radius Simplifies frame installation - Saves money by reducing the number of different jumper lengths that have to be kept in inventory - Minimizes risk of microbends or damage to fiber Sliding Adapter Packs Promotes high density Provides easy access to connectors - Saves valuable floor space - Reduces time required for operations and maintenance Intelligent Cable Routing System No fiber cross-over points Multiple vertical troughways - Reduces maintenance time due to easier removal and tracing of jumpers and minimizes fiber “weaving” 10/03 • 100571 600 mm Products 3 www.adc.com • +32-2-712-65-00 • +32-2-712-65-42 3 Next Generation Frame 600 mm Products Fiber Main Distributing Frame (FMDF) The FMDF is the cornerstone of the NGF product line. This innovative frame has six rear horizontal troughs. This abundant trough space minimizes fiber pile up and congestion leading to easier jumper traceability and removal. The frame has twelve Fiber Termination Block (FTB) mounting positions equally divided between vertical columns on the left and right sides of the frame as shown in the figure below. The frame is 600 mm wide x 600 mm deep. The built-in jumper storage panel will store up to 5 meters of jumper slack. Catalog Number NGF-ETSIMDF6060 Dimensions 2.2 m x 600 mm x 600 mm Ordering Information Description 600 mm FMDF frame section 600 mm 600 mm FTB Mounting Position (12) Right Vertical Left Vertical Horizontal Trough (6) Jumper Storage Panel Front ISO View Front View Side View 10/03 • 100571 600 mm Products 4 www.adc.com • +32-2-712-65-00 • +32-2-712-65-42 4 Next Generation Frame 600 mm Products Front Facing Fiber Main Distributing Frame (F3MDF) The F3MDF is designed for single-sided access applications and may be mounted up against a wall or back- to-back to save floor space. Unlike the FMDF, the more compact F3MDF is equipped with a single 230 mm horizontal trough. The F3MDF has twelve FTB mounting positions equally divided between vertical columns on the left and right sides of the frame as shown in the figure below. The frame is 600 mm wide x 480 mm deep. The built-in jumper storage panel will store up to 5 meters of jumper slack. 2.2 m 600 mm 480 mm Jumper Storage Panel Right Vertical Left Vertical FTB Mounting Position (12) Horizontal Trough (6) Front ISO View Front View Side View Catalog Number NGF-ETSIF3MDF6048 Dimensions 2.2 m x 600 mm x 480 mm Ordering Information Description 600 mm F3MDF frame section 10/03 • 100571 600 mm Products 5 www.adc.com • +32-2-712-65-00 • +32-2-712-65-42 5 2.14 m 480 mm 480 mm FTB Mounting Position Jumper Storage Panel Next Generation Frame 600 mm Products Fiber Slim Rack The Fiber Slim Rack is designed for lower density applications than the FMDF or F3MDF. It has six FTB mounting positions and is designed for single-sided access applications. The Slim Rack is intended for use in a single frame application and should not be used in a multiframe lineup. The built-in jumper storage panel will store up to 5 meters of jumper slack. When ordering FTBs for the Slim Rack, remember that only left oriented blocks are used on this frame. Front ISO View Front View Side View Catalog Number NGF-SLM7A100 Dimensions 2.14 m x 480 mm x 480 mm Ordering Information Description NGF Fiber Slim Rack frame section 10/03 • 100571 600 mm Products 6 www.adc.com • +32-2-712-65-00 • +32-2-712-65-42 Catalog Number NGF-TB Block Style 1 2 3 4 1 2 4 3 SC FC/ST ® E-2000 LX.5 ® /LC Cable Exit Direction U D Upward Downward Block Configuration A B C M 48 72 96 144 (LX.5 ® or LC only)* Block Orientation L R Left Right Adapter Type (62.5/125) Multimode 9 A 5 Y P SC FC ST ® LX.5 ® (144 only) LC (144 only) OR Adapter Type Singlemode 7 8 L 2 3 Q 4 V N X K SC ultra polish SC ultra polish, zirconia sleeve SC 8° angled polish FC ultra polish FC ultra polish, zirconia sleeve FC 8° angled polish ST ® ultra polish E-2000 angled polish LX.5 ® ultra polish (144 only) LX.5 ® angled polish (144 only) LC ultra polish (144 only) 5 6 Next Generation Frame 600 mm Products Fiber Termination Blocks (FTB) Unterminated FTBs without fiber can be ordered fully loaded with adapters or empty (no adapters), in which case the adapter packs for the block must be ordered separately (see page 12). Before ordering, determine the block orientation and cable exit direction. Unterminated FTBs may be ordered with a “left” orientation (mounts on the left side of the frame) or a “right” orientation (mounts on the right side of the frame). The cable exit direction will be either “upward” (cables terminated to the rear side of the block exit up toward the top of the frame) or “downward” (cables terminated to the rear side of the block exit down toward the bottom of the frame). All blocks with adapters only are configured to terminate single or dual jumpers on the rear of the block. If a multifiber breakout style cable (i.e., OSP/IFC) is to be terminated to the rear of the block, a separate clamping kit is required (see page 7). Definition of Variables 1 2 3 4 5 Block Style General adapter type required in the FTB Block Configuration Maximum number of terminations that the FTB will accommodate when fully loaded Block Orientation Vertical column of the frame the FTB is to be mounted on Cable Exit Direction Direction the equipment jumpers or OSP cable will exit from the FTB Adapter Type Specific adapter type required in the FTB * 144 blocks using style 1, 2, or 3 cannot be used in 26" wide NGF frames 10/03 • 100571 600 mm Products 7 www.adc.com • +32-2-712-65-00 • +32-2-712-65-42 7 Next Generation Frame 600 mm Products Fiber Termination Blocks Clamping kit includes: Cable clamp, protective cover and fanout bracket. It is required when terminating a multifiber breakout style cable to the rear of the block. 72 position block loaded with jumpers 72 position block loaded with multifiber breakout cable 72 position block with clamping kit Protective Cover Fanout Bracket Cable Clamping Kit Rear Cable Management Tray for 144 Block Conversion Kit Description Catalog Number Block style originally purchased All 48- and 72-position blocks NGF-ACCOSPKIT02 96- or 144-position Left Up Blocks NGF-ACCRCMSLU 96- or 144-position Right Up Blocks NGF-ACCRCMSRU 96- or 144-position Left Down Blocks NGF-ACCRCMSLD 96- or 144-position Right Down Blocks NGF-ACCRCMSRD Ordering Information 10/03 • 100571 600 mm Products 8 www.adc.com • +32-2-712-65-00 • +32-2-712-65-42 8 Next Generation Frame 600 mm Products Fiber Termination Blocks (FTB) Preterminated Preterminated FTBs are available with either indoor or outdoor rated cable in ribbon or stranded configurations. All blocks are 100% factory tested to guarantee continuity and reliable connections. Preterminated FTBs make installation quick and easy, reducing labor costs. Before ordering, determine the block orientation and cable exit direction. Preterminated FTBs may be ordered with a “left” orientation (mounts on the left side of the frame) or a “right” orientation (mounts on the right side of the frame). The cable exit direction will be either “upward” (cables terminated to the rear side of the block exit up toward the top of the frame) or “downward” (cables terminated to the rear side of the block exit down toward the bottom of the frame). Preterminated Fiber Termination Blocks arrive from the factory with either IFC or OSP Cables Fiber cable easily uncoils during installation Fiber Termination Block ships inside the drum Ordering information follows on next page. Fiber Termination Block loaded with multifiber breakout cable Definition of Variables 1 Block Style General adapter type required in the FTB 2 Block Configuration Maximum number of terminations that the FTB will accommodate when fully loaded 3 Block Orientation Vertical column of the frame the FTB is to be mounted on 4 Cable Exit Direction Direction the equipment jumpers or OSP cable will exit from the FTB 5 Adapter/Connector #1 Specific adapter/connector type required in the FTB. Refers to the adapter/ connector type at the FTB 6 Connector #2 Specific connector type required at the cable end opposite the FTB 7 Cable Type Type of cable to be terminated to the FTB 8 Cable Length Required length of the cable terminated to the FTB 10/03 • 100571 600 mm Products 9 www.adc.com • +32-2-712-65-00 • +32-2-712-65-42 9 Catalog Number NGF-TB †Other cable types are available upon request. Please contact your ACD representative. Glass Type Glass Type IFC Type Multimode (62.5/125) OR OR AM BM DM 2M VM WM YM 12-fiber stranded 24-fiber stranded 36-fiber stranded 48-fiber stranded 72-fiber stranded 96-fiber stranded 144-fiber stranded Corning Corning Corning Corning Corning Corning Corning Length in meters Cable Length XXX 8 Block Style 1 2 3 4 SC FC/ST ® E-2000 LX.5 ® /LC Cable Exit Direction U D Upward Downward Block Configuration A B C M 48 72 96 144 (LX.5 ® or LC only)** Block Orientation L R Left Right 1 4 2 3 IFC Type Singlemode † Glass Type ZB ZC ZD AA BA CA 2A VA DA FH GA HA MA JA KA EG FJ 72-fiber stranded 96-fiber stranded 144-fiber stranded 12-fiber stranded 24-fiber stranded 36-fiber stranded 48-fiber stranded 72-fiber stranded 96-fiber stranded 144-fiber stranded 12-fiber ribbon 24-fiber ribbon 36-fiber ribbon 48-fiber ribbon 72-fiber ribbon 96-fiber ribbon 144-fiber ribbon House Cable* House Cable* House Cable* Corning Corning Corning Corning Corning Corning Corning Sumitomo Sumitomo Sumitomo Sumitomo Sumitomo Sumitomo Sumitomo 7 OSP Cable Type Singlemode 72 fiber stranded dielectric 96-fiber ribbon dielectric 96-fiber stranded dielectric 144-fiber stranded dielectric 144-fiber ribbon dielectric VT VW EN FL FM Pirelli Pirelli Pirelli Pirelli Pirelli 0 9 A 5 Y P No connector/stub end SC FC ST ® LX.5 ® (144 only) LC (144 only) Connector #2 Singlemode 0 7 8 L 2 3 Q 4 V N X K No connector/stub end SC ultra polish SC ultra polish, zirconia sleeve SC 8° angled polish FC ultra polish FC ultra polish, zirconia sleeve FC 8° angled polish ST ® ultra polish E-2000 angled polish LX.5 ® ultra polish (144 only) LX.5 ® angled polish (144 only) LC ultra polish (144 only) Connector #2 Multimode (62.5/125) OR 6 OR Adapter/Connector #1 Multimode (62.5/125) 9 A 5 Y P SC FC ST ® LX.5 ® (144 only) LC (144 only) Adapter Type Singlemode 7 8 L 2 3 Q 4 V N X K SC ultra polish SC ultra polish, zirconia sleeve SC 8° angled polish FC ultra polish FC ultra polish, zirconia sleeve FC 8° angled polish ST ® ultra polish E-2000 angled polish LX.5 ® ultra polish (144 only) LX.5 ® angled polish (144 only) LC ultra polish (144 only) 5 Next Generation Frame 600 mm Products Preterminated FTBs See previous page for definition of variables. *House cable will use Corning SMF28, Sumitomo, Alcatel or similar singlemode fiber based on current market availability. ** 144 blocks using style 1, 2, or 3 cannot be used in 26" wide NGF frames 10/03 • 100571 600 mm Products 10 www.adc.com • +32-2-712-65-00 • +32-2-712-65-42 10 Next Generation Frame 600 mm Products Fiber Combination Blocks (FCB) Fiber Combination Blocks provide a place to terminate pigtails and splice IFC/OSP cables on the frame. The blocks are available with several different adapter types in block configurations of 48-, 72-, or 96-positions. Also, a 144-position FCB is available using an LX.5 ® or LC adapter. The termination portion of the fiber combination block utilizes sliding adapter packs to gain easy access to connectors on both the front and rear side of the block. The block is available with factory-installed pigtails for easy installation. Splice trays are shipped with the block if ordered with pigtails; otherwise trays must be ordered separately. The block is shipped with a cable clamp for OSP/IFC. The FCB occupies two mounting positions on a frame section. Before ordering, determine the block orientation. FCBs may be ordered with a “left” orientation (mounts on the left side of the frame) or a “right” orientation (mounts on the right side of the frame). Ordering information follows on next page. Definition of Variables 1 2 3 4 5 6 7 Block Style General adapter type required in the FCB Block Configuration Maximum number of terminations that the FCB will accommodate when fully loaded Block Orientation Vertical column of the frame the FCB is to be mounted on Adapter/Connector Type Specific adapter/connector type required in the FCB Pigtail Type Type of pigtail required Number of Pigtail Assemblies Number of pigtails to be pre-installed in the FCB Splice Chip Type of splice chip required for splice trays 10/03 • 100571 600 mm Products 11 www.adc.com • +32-2-712-65-00 • +32-2-712-65-42 11 Catalog Number NGF-CB 2 Splice Chip 0 1 2 3 6 7 8 9 4 Empty Bare fusion Heat shrink fusion Mechanical (Elastomeric) Nortel QPAK Swiss ® ANT Rotary FibrLok ® 16 position heat shrink fusion Block Style 1 2 3 4 SC FC/ST ® E-2000 LX.5 ® /LC Block Configuration A B C M 48 72 96 144 (LX.5 ® or LC only) 1 2 Number of Pigtail Assemblies XX Number of assemblies 6 Pigtail Type 0 1 2 4 5 No pigtails 12-fiber pigtail 12-fiber stranded Maxi-Strip 8-fiber pigtail 12-fiber ribbon 5 7 Block Orientation L R Left Right 3 A 5 9 Y P FC ST ® SC LX.5 ® (144 only) LC (144 only) 4 OR Adapter/Connector Type Multimode (62.5/125) Adapter Type Singlemode 7 8 L 2 3 Q 4 V N X K SC ultra polish SC ultra polish, zirconia sleeve SC 8° angled polish FC ultra polish FC ultra polish, zirconia sleeve FC 8° angled polish ST ® ultra polish E-2000 angled polish LX.5 ® ultra polish (144 only) LX.5 ® angled polish (144 only) LC ultra polish (144 only) 4 1 Next Generation Frame 600 mm Products Fiber Combination Blocks (FCB) 1 144-termination block requires the use of either: Mechanical (elastomeric) splice tray when using mass fusion ribbon splicing Nortel QPAK splice tray when using single fiber heat shrink fusion splicing 144 blocks using block style 1, 2, or 3 cannot be used in 26" wide NGF frames Splice Trays For Fiber Combination Block Catalog Number FST - DRS Splice Tray Type 00 FT HS MT NT ANT RT 3M Empty tray* Bare fusion Heat shrink fusion Mechanical (elastomeric) Nortel QPAK Swiss ANT Rotary FibrLok ® * Maximum size of chip allowed in empty tray: .3"H x 2.5"W x 3.6"L Note: For LX.5 ® FCB with 12 fiber ribbon pigtails, select mechanical splicing only. For LX.5 ® FCB with 12 fiber stranded pigtails select Nortel QPAK (compatible with heat shrink fusion), bare fusion or Swiss ANT only. Number of Splices 12 24 - 12 splices 24 splices 1 2 [...]... +32-2-712-65-42 13 Next Generation Frame 600 mm Products 600 mm Products Fiber Optic Terminal Jumper Storage Bay 2.2 m 10/03 • 100571 300 mm Front ISO View 600 mm Front View (NGF-ACCFOTSB300 Shown) Side View Ordering Information Description Dimensions Catalog Number FOT storage bay for 600 mm FMDF lineups 2.2 m x 300 mm x 600 mm NGF-ACCFOTSB300 FOT storage bay for 600 mm F3MDF lineups (not shown) 2.2 m x 300 mm x... hole spacing) 2.2 m x 600 mm x 480 mm NGF-ETSIF3EB6048-19 www.adc.com • +32-2-712-65-00 • +32-2-712-65-42 15 Next Generation Frame 600 mm Products Accessories End Guard The end guard provides protection for the fibers entering and exiting frames at the ends of a lineup Ordering Information Catalog Number FMDF end guard, 600 mm deep NGF-ETSIACCEG F3MDF end guard, 480 mm deep 600 mm Products Description... code "E" only) 4 pack / 4 pack 6 pack / 6 pack (all block code "M" blocks) +32-2-712-65-42 12 Next Generation Frame 600 mm Products 600 mm Products Value-Added Module System Chassis ADC’s Next Generation Frame (NGF) Value-Added Modules are designed to support emerging circuit requirements This high-density fiber frame solution provides unlimited expansion while optimizing fiber cable management The NGF... Equipment Bays are available for FMDF lineups (600 mm deep) and F3MDF lineups (480 mm deep) 2.2 m 600 mm 600 mm NGF-ETSIEB6060-19 Ordering Information 10/03 • 100571 Description Dimensions Catalog Number Equipment bay for FMDF lineups For 19" (48.26 cm) equipment (maximum equipment width) (36) rack unit mounting spaces available (EIA hole spacing) 2.2 m x 600 mm x 600 mm NGF-ETSIEB6060-19 Equipment bay for... 10/03 • 100571 600 mm Products The OMX frame is 600 mm x 300 mm and has ten mounting positions for the termination, splice and jumper storage modules The OMX 800 frame is 800 mm x 300 mm and also has ten mounting positions for the termination, splice and jumper storage modules OMX Slack Storage Solutions The OMX jumper storage module enables storage of fiber-optic jumper slack within an OMX frame Each... Optical Distribution Frame Introduction ADC has developed the OMX™ optical distribution frame to meet these demands Designed with total front access, the OMX can be installed back-to-back or against a wall to save valuable office floor space This high-density frame terminates and splices up to 576 fibers in a 600 mm x 300 mm footprint and 864 in a 800 mm x 300 mm footprint The OMX fiber frame protects fiber... for 600 mm FMDF lineups 2.2 m x 300 mm x 600 mm NGF-ACCFOTSB300 FOT storage bay for 600 mm F3MDF lineups (not shown) 2.2 m x 300 mm x 480 mm NGF-F3ACCFOTSB300 www.adc.com • +32-2-712-65-00 • +32-2-712-65-42 14 Next Generation Frame 600 mm Products Equipment Bay 600 mm Products The NGF Equipment Bay provides a mounting location for 19-inch rack mount equipment within an FMDF lineup The equipment deployment... provides off -frame storage of jumper slack ADC recommends the use of 2 mm patch cords to maximize the cable management potential of the OMX www.adc.com • +32-2-712-65-00 • +32-2-712-65-42 18 OMX™ Optical Distribution Frame Frame Section 10/03 • 100571 600 mm Products The OMX frame section provides mounting locations for termination, splice and storage modules It is a completely front-facing frame; all... the frame A lower trough allows multiple frames to be mounted in a continuous lineup The frame is shipped with lockable front doors Preconfigured bays are available; please contact your ADC representative for ordering information OMX 600 Frame Section Front ISO View OMX 800 Frame Section Front ISO View Ordering Information Description Dimensions (HxWxD) Catalog Number OMX 600 frame section 2200 x 600. .. Distribution Frame Frame Accessories OMX Jumper Storage Module 600 mm Products The OMX jumper slack storage module provides for jumper storage functionality within the frame Up to five jumper storage modules can be mounted on one side of an OMX frame Jumper storage modules must be mounted to the frame starting in the bottom position Ordering Information Description Catalog Number OMX 600 jumper storage . 100571 600 mm Products 2 www.adc.com • +32-2-712-65-00 • +32-2-712-65-42 2 Next Generation Frame 600 mm Products Introduction Frames ADC’s Next Generation Frame. Number NGF-ETSIMDF6060 Dimensions 2.2 m x 600 mm x 600 mm Ordering Information Description 600 mm FMDF frame section 600 mm 600 mm FTB Mounting Position (12) Right Vertical Left Vertical Horizontal Trough

Ngày đăng: 24/01/2014, 11:20

Từ khóa liên quan

Tài liệu cùng người dùng

Tài liệu liên quan