Tài liệu Quad Loop Extender Module (WQLX) pptx

4 242 0
Tài liệu Quad Loop Extender Module (WQLX) pptx

Đang tải... (xem toàn văn)

Thông tin tài liệu

Soneplex ® WDM Quad Loop Extender Module (WQLX) The Soneplex Single Fiber Quad Loop Extender (WQLX) module converts four multiplexed DS1 signals into an optical DS2 using wave division multiplexing (WDM) optics. Similar to ADC’s Quad Loop Extender (QLX), the WQLX transports the signal over single mode fiber, but uses only one fiber instead of two. The same module is also used at the remote end to convert the optical DS2 back into four DS1s at the customer premises. ADC’s Soneplex system is the lowest total cost solution to expand local loop business services. In addition to HDSL, HDSL2, HDSL4, traditional T1 repeater and optical DS2 technologies, Soneplex‘s advanced diagnostics and management functions allow maximum control and visibility throughout local networks. Focused on flexible, end-to-end solutions, the Soneplex system approach provides robust, cost-effective transmission and access over either fiber or copper, using a single platform. Features: • Saves existing fiber plant by using half the fiber of other modules • 1+1 protection switching • 1310/1550 nm single fiber optical laser transport with optical budget of 18 dB • Extensive network management with a Soneplex Shelf Controller Unit • Supports central office and remote applications • Central office and remote alarm capability 2 www.adc.com • +1-952-938-8080 6/02 • 4085 Soneplex Quad Loop Extender Module Description The protected mode requires a pair of WQLX modules at each end of the circuit. In a 1+1 line protected system, identical traffic is transmitted across both the working and protect paths. Up to seven unprotected or protected systems can be deployed from a single Soneplex Loop Extender system. The Soneplex WQLX module is a fiber loop converter that provides cost-effective, reliable transmission of four DS1 signals at distances up to approximately 22 miles (18 dB budget). The system can be configured for either protected or unprotected service. The WQLX provides extensive alarms and diagnostic capabilities. Protection Switching: Protection is accomplished using automatic protection switching (APS). APS is completed within 50 ms of the decision and occurs when: • A module fail condition occurs or the module is removed while on-line • An optical failure occurs (optical loss of signal (LOS), optical out of frame (OOF), optical bit error rate (BER) threshold exceeded) • DS1 transmitter failure occurs The unprotected mode requires one WQLX module per four DS1s installed in the Soneplex Loop Extender chassis at the central office and one WQLX module at the customer (remote) end. W Q L X CO Customer Location 4 Electrical DS1s W Q L X RMT Central Office One Single Mode Fiber Soneplex Loop Extender System Unprotected Configuration W Q L X Soneplex Loop Extender System Customer Location 4 Electrical DS1s Central Office CO W Q L X CO W Q L X RMT W Q L X RMT Protected Configuration 3 www.adc.com • +1-952-938-8080 6/02 • 4085 Soneplex Quad Loop Extender Module Applications Building Risers The WQLX can also be used to distribute HiCap DS1s to various floors in a building using the Soneplex Loop Extender chassis with existing fiber facilities. For flexibility, the same system can also support copper transmission from the same chassis. The Soneplex Loop Extender is located in the building basement or a closet, feeding one or more customers in the building. The WQLX module is ideal for low-density T1 based applications such as PCS cell sites and building risers. PCS Cell Sites With the installation of the Soneplex Loop Extender system in the central office, a local exchange carrier or a remote PCS service provider can serve a remote cell site using a WQLX remote module and a two or four position chassis. As the PCS market continues to expand, the ability to establish cell sites and initiate service quickly is essential. Since most sites require one or two T1 lines, the Soneplex Loop Extender with the WQLX is ideal. A majority of cellular sites are constructed with 24 VDC sources as the primary power supply. The requirement to feed this growing application over a fiber network demands a system operating with a 24 VDC power feed. ADC has developed unique WQLX modules to serve this application. The functionality is identical to the -48VDC versions of the WQLX. CELLULAR SITE WQLX Remote 1 - 4 DS1s W Q L X Soneplex Loop Extender System CO W Q L X CO CENTRAL OFFICE/CEV/HUT/CABINET CELLULAR SITE WQLX Remote 1 - 4 DS1s 24 Volt Power Supply Optical DS2 24 Volt Power Supply Network Interface 1 - 28 DS1s PCS Cell Sites Soneplex Loop Extender System WQLX Remote 1-4 DS1s WQLX Remote 1-4 DS1s HDSL or HDSL2 Remote 28 DS1s MUX Building Riser ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, Minnesota USA 55440-1101 Specifications published here are current as of the date of publication of this document. Because we are continuously improving our products, ADC reserves the right to change specifications without prior notice. At any time, you may verify product specifications by contacting our headquarters office in Minneapolis. ADC Telecommunications, Inc. views its patent portfolio as an important corporate asset and vigorously enforces its patents. Products or features contained herein may be covered by one or more U.S. or foreign patents. 4085 12/02 Revised © 2002 ADC Telecommunications, Inc. All Rights Reserved An Equal Opportunity Employer Web Site: www.adc.com From North America, Call Toll Free: 1-800-366-3891 • Outside of North America: +1-952-938-8080 Fax: +1-952-946-3292 For a complete listing of ADC's global sales office locations, please refer to our web site. Specifications WQLX Dimensions (HxWxD): Weight: Operating Temperature: Operating Humidity: DS1 Line Rate: DS1 Line Codes: DS1 Frame Formats: Optical Wavelength: Optical Budget: Transmission Range: Optical Line Rate: Connectors Supported: Input Power: Power Consumption: DS1s Per Module: Modules per Chassis: NEBS Level 1: NEBS Level 3: UL 1950: 4.4 x 1.4 x 9.2 in. (11.2 x 3.5 x 23.25 cm) 0.8 Ibs. (0.363 kg) -40ºF to 149ºF (-40ºC to 65ºC) 5% to 95%, non-condensing 1.544 Mbps AMI or B8ZS SF, ESF, SLC96 or unframed 1310/1550 ± 40 nm 18 dB Up to 22 miles, depending on fiber loss 6.312 Mbps SC or FC -42VDC to -56VDC 6 W 4 Soneplex Loop Extender; 7 without protection, 14 with protection GR-63 Physical Protection GR-63 Physical Protection, GR-1089 Electromagnetic Compatibility General safety requirements for electronic equipment Description Catalog Number Soneplex Single Fiber Quad Loop Extender Module CO & Remote -48VDC CO with SC connector WQLXC-SCA100 CO with FC connector WQLXC-FCA100 Remote with SC connector WQLXR-SCA100 Remote with FC connector WQLXR-FCA100 Ordering Information . Soneplex ® WDM Quad Loop Extender Module (WQLX) The Soneplex Single Fiber Quad Loop Extender (WQLX) module converts four multiplexed. +1-952-938-8080 6/02 • 4085 Soneplex Quad Loop Extender Module Description The protected mode requires a pair of WQLX modules at each end of the circuit.

Ngày đăng: 17/01/2014, 09:20

Tài liệu cùng người dùng

  • Đang cập nhật ...

Tài liệu liên quan