Tài liệu ClearGain® Ground-Mounted Amplifiers doc

12 305 0
Tài liệu ClearGain® Ground-Mounted Amplifiers doc

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

Thông tin tài liệu

www.adc.com • +1-952-938-8080 • 1-800-366-3891 Spec Sheet ClearGain ® Ground-Mounted Amplifiers As mobile usage continues to increase, service providers are faced with the challenge of optimizing and expanding their wireless networks to provide new and existing services. ADC’s ClearGain ® Ground-Mounted Amplifiers (GMAs) minimize the cost of network expansion and improve quality of service, allowing service providers to increase profitability from new and existing services. ClearGain GMAs improve signal quality by boosting the uplink signal of a mobile system to increase receiver performance and improve overall coverage. Features • Slim,stackabledesignconservesrackspaceandeliminatestowerclimbs • Advancedfilteringmaintainsthelowestpossiblenoisefigureforimproved QualityofService(QoS) • HighlyadvancedLNAamplifiesRXsignalforimprovedreceiverperformance and increase in coverage • Dualduplexfeaturereducesthenumberoffeedercablerunsbyprovidingsimultaneous operationofTXandRXwithlowTXloss • Modularsystemisfullycompatiblewithallbasestations • PowerandalarmingforuptothreeGMAunits 2/08•105192AE ClearGain ® Ground Mounted Aplifiers 2 www.adc.com • +1-952-938-8080 • 1-800-366-3891 Introduction Unacceptable network quality is one of the main reasons for mobile subscriber churn. With increasing industry churn rates, a service provider’s entire customer base could be lost in as few as three years. The cost of acquiring new subscribers to replace the existing customer base can be enormous. Improvements in quality of service can directly impact a service provider’s profitability through the cost savings associated with increased subscriber retention and the additional revenue gained from increased billable minutes of use resulting from improved signal quality. Whilesubscribersarewillingtopayapremiumfordataservices,improvedQoSisnecessarytoprovide new data services. Due to the tradeoff between bit rate and bandwidth inherent to data services, improved signal quality is required to achieve the same level of performance at even higher data rates. ADC’s ClearGain GMAs help provide this improvement in signal quality. ClearGainGMAsimprovesignalqualitybyboostingtheuplink(RX)signalofamobilesystem.GMAs perform this amplification with the lowest possible noise contribution, resulting in a substantial increase inreceiverperformanceandanimprovementinoverallcoverage.TheseimprovementsinQoSallow mobile subscribers to place more calls, make longer calls, and successfully complete calls in an expanded geographic area, resulting in increased revenue. SystemOverview The ClearGain GMA system is modular, consisting of an amplification module and a power distribution unit(PDU),providingfullcompatibilitywithallbasestations. The ClearGain GMA offers dual duplex operation and incorporates a highly advanced fixed-gain, low- noiseamplifier(LNA)andhigh-performancefiltersforaddedreliability. ClearGain ® Ground-Mounted Amplifiers Antenna Base Station BTS GMA BTS 2/08•105192AE ClearGain ® Ground Mounted Aplifiers 3 www.adc.com • +1-952-938-8080 • 1-800-366-3891 DD800FullBandGMATypicalSpecifications ELECTRICAL Nominal Impedance of RF Inputs and Outputs: 50Ohm Frequency Range TX: 869-894MHz RX: 824-849MHz Passband (RX) Gain: 12dB Noise Figure: 1.4dB Dynamic Range Input at 1 dB Gain Compression: 0 dBm IIP3: +13dBm Insertion Loss TX Path (TX to ANT): .4dB 851 MHz Rejection: <30dB Bypass Insertion Loss: 2.0 dB Isolation in Tx Path: 80 dB Rejection 1850-1998 MHz: 80 dB Max Input Power: +10dBm Passband Return Loss TX Band: >18dB RX Band: >18dB Intermodulation: -120dBm Maximum Input Power (RMS Power): 500W TX Filter Rejection in RX Band: 40dB POWER Operational Voltage: 7to18Vdc Operational Current: 140±10mA Alarm Current Level: 350±10mA PHYSICAL (Three Sector Site with Diversity) Dimensions (HxWxD): 3.5inx19inx12.5in Weight: 22 lbs. CONNECTORS Antenna Connector: 7/16DINfemale BTS Connector: 7/16DINfemale ENVIRONMENTAL Operating Temperature: -40°Cto60°C Lightning Protection: IEC61000-4-5 Vibration Storage: ETS3019-1-1 Transport: ETS3019-1-2 Operation: ETS3019-1-3 REGULATORY EMC: ETS300342-2 APPROVALS FCC: Part15,ClassA UL: 1950 QUALITY MTBF: 900,000hours ClearGain ® Ground-Mounted Amplifiers 2/08•105192AE ClearGain ® Ground Mounted Aplifiers 4 www.adc.com • +1-952-938-8080 • 1-800-366-3891 ClearGain ® Ground-Mounted Amplifiers DD1900FullBandTypicalSpecifications ELECTRICAL Nominal Impedance of RF Inputs and Outputs: 50Ohm Frequency Range TX:  1930-1990MHz RX:  1850-1910MHz Passband (RX) Gain:  13dB Noise Figure:  1.0dB Dynamic Range Input at 1 dB Gain Compression: +3dBm IIP3:  +15dBm Insertion Loss TX Path (TX to ANT): .4dB 1915 MHz Rejection:  <15dB 1916 MHz Rejection:  <30dB Isolation in Tx Path: 80 dB Rejection 824-894 MHz: 80 dB Max Input Power:  +10dBm Passband Return Loss TX Band:  >18dB RX Band:  >18dB Intermodulation: -120dBm Maximum Input Power (RMS Power): 250W TX Filter Rejection in RX Band: 40dB POWER Operational Voltage: 7to20Vdc Operational Current: 140±10mA Alarm Current Level: 350±20mA PHYSICAL (Three Sector Site with Diversity) Dimensions (HxWxD): 12.25inx19inx12.5in Weight: 80 lbs. CONNECTORS Antenna Connector: 7/16DINfemale BTS Connector: 7/16DINfemale ENVIRONMENTAL Operating Temperature: -40°Cto60°C Lightning Protection: IEC61000-4-5 Vibration Storage:  ETS3019-1-1 Transport:  ETS3019-1-2 Operation:  ETS3019-1-3 REGULATORY EMC: ETS300342-2 APPROVALS FCC: Part15,ClassA UL: 1950 QUALITY MTBF: 900,000hours 2/08•105192AE ClearGain ® Ground Mounted Aplifiers 5 www.adc.com • +1-952-938-8080 • 1-800-366-3891 DD1900FullBandwithDD800Diplexer TheDD1900FullBandwithDD800DiplexerGMAamplifiesthefull1900MHzbandtomaximizesignal qualityandoptimizecoveragewhilepassingthroughthe800MHzbandwithoutamplification.This allowsthe1900MHzsystemtobeamplifiedwithoutaffectingtheexisting800MHzsystem. TheClearGainDD1900FullBandwithDD800DiplexerGMAfeaturesaslim,modularsystemthatcan beusedinathreesectorBTSoranOmniBTS.Theamplificationmoduleisonly2RUhigh.Therefore,an entireGMAconfiguredforathree-sectorBTSwillonlytakeup7RUina19"rack. ClearGain ® Ground-Mounted Amplifiers 1900 Antenna 800 Antenna Base Station 800 ANT BTS 800/1900 Diplexer 800 BTS 1900 BTS 1900 ANT 1900 GMA w/800 Diplexer 1900 BTS 800 BTS 2/08•105192AE ClearGain ® Ground Mounted Aplifiers ClearGain ® Ground-Mounted Amplifiers 6 www.adc.com • +1-952-938-8080 • 1-800-366-3891 DD1900FullBandwithDD800DiplexerTypicalSpecifications ELECTRICAL Nominal Impedance of RF Inputs and Outputs: 50Ohm Frequency Range TX:  1930-1990MHz RX:  1850-1910MHz Passband (RX) Gain:  13dB Noise Figure:  1.0dB Dynamic Range Input at 1 dB Gain Compression:  +3dBm IIP3:  +15dBm Insertion Loss TX Path (TX to ANT): .4dB 1915 MHz Rejection:  <15dB 1916 MHz Rejection:  <30dB Isolation in Tx Path: 80 dB Rejection 824-894 MHz: 80 dB Max Input Power:  +10dBm Passband Return Loss TX Band:  >18dB RX Band:  >18dB Intermodulation: -120dBm Maximum Input Power (RMS Power): 250W TX Filter Rejection in RX Band: 40dB POWER Operational Voltage: 7to20Vdc Operational Current: 140±10mA Alarm Current Level: 350±20mA PHYSICAL (Three Sector Site with Diversity) Dimensions (HxWxD): 12.25inx19inx12.5in Weight: 80 lbs. CONNECTORS Antenna Connector: 7/16DINfemale BTS Connector: 7/16DINfemale ENVIRONMENTAL Operating Temperature: -40°Cto60°C Lightning Protection: IEC61000-4-5 VIBRATION Storage: ETS3019-1-1 Transport: ETS3019-1-2 Operation: ETS3019-1-3 2/08•105192AE ClearGain ® Ground Mounted Aplifiers 7 www.adc.com • +1-952-938-8080 • 1-800-366-3891 ClearGain ® Ground-Mounted Amplifiers PowerDistributionUnit Time and space are important considerations when selecting and installing wireless components at base transceiver station sites. The simple, compact design of ADC’s ClearGain ® PowerDistributionUnit(PDU) is intended to help service providers save both. From a compact unit that is easily mounted on a wall or arack,ClearGainPDUsprovidepowerandalarmingforADC’sground-mountedamplifiers. Features: • Providespowerandalarmfunctionsforon-sitemonitoringofGroundMountAmplifiers(GMAs) • Wall-orrack-mountabletofitavailablespace • LEDindicatorsforalarmfunctions • Simple,compactdesignallowsforeasyinstallationandconnections 2/08•105192AE ClearGain ® Ground Mounted Aplifiers 8 www.adc.com • +1-952-938-8080 • 1-800-366-3891 ClearGain ® Ground-Mounted Amplifiers PowerDistributionUnitTypicalSpecifications ELECTRICAL Input Voltage: 20-56Vdcpositive/negativeground Output Voltage: 18Vdceach Maximum Current Drawn: 3.8A PHYSICAL Dimensions (HxWxD): 43x196x103mm(1.69"x7.72"x4.06") Weight: <460g Color: Silver CONNECTORS Output for GMAs: SMB,male(qty6) Power Connector: 4-pinmale General Alarm Connector: 3-pinmale Indicators Singlemode PDU: GreenOK/NOKLEDs Red General Alarm LED Alarm output LEDs Alarmoutputisisolated3-pinrelayconnection   Normallyopenandnormallyclosedconnection available ENVIRONMENT Storage: ETS3019-1-1 Transport: ETS3019-1-2 Operation: ETS3019-1-3 Housing: IP40 Temperature Range (Indoor Use): -20ºCto+65ºC(-4ºFto+149ºF) Lightning Protection: IEC1000-4-5EMC Approvals: UL QUALITY MTBF250,000hours.Manufacturedunder   ISO9001qualitysystem ACCESSORIES Basic Accessories: Powersupplycable(10m),alarmcable   (10m),groundingcable(2m)andwall mounting screws Optional Accessories: Mountinghardwarefor19"rackmount 2/08•105192AE ClearGain ® Ground Mounted Aplifiers ClearGain ® Ground-Mounted Amplifiers 9 www.adc.com • +1-952-938-8080 • 1-800-366-3891 Description Catalog Number ClearGain Ground Mounted Aplifiers 800 Fullband CG0800DD025DG00 1900Fullband CG1900DD060DG00 1900FullbandGMAw/800Diplexer CG1900DD060DGBP ClearGain Power Distribution Unit ClearGainSingleModePDU,Includespowercableandgroundingcable CG-PDU-SMPWR PDUMountingBracket AUX-000076 Ordering Information 2/08•105192AE ClearGain ® Ground Mounted Aplifiers ClearGain ® Ground-Mounted Amplifiers 10 www.adc.com • +1-952-938-8080 • 1-800-366-3891 Creating a Bill of Materials A typical site includes three components in various quantities. You have three GMA options:  1.CG0800DD025DG00 800DDFullbandGMA  2.CG1900DD060DG00 1900DDFullbandGMA  3.CG1900DD060DGBP 1900DDFullbandGMAw/800MHzDiplexer  TheGMAsinclude: • Mountinghardware • Groundinglug Orderinginformation:Orderonepersector You have one PDU option:  1.CG-PDU-SMPWR SinglePowerPDU ThePDUincludes: • MountingHardware • PowerCable(length10meters) • AlarmCable(length10meters) • GroundingCable/strap(length1.5meters) Orderinginformation:Orderonepersite You have one PDU mounting option:  1.AUX-000076 MountingbracketforonesingleordualmodePDUtoa19"rack Orderinginformation:Orderonepersite Optional Accessories: GMA23”RackBrackets EB-35P PDU23”RackBrackets EB-17P SiemensCabinetMountingBracket AUX-000084 GMAOutdoorEnclosure GC0000000000GEN GMAOutdoorEnclosureReplacementSealKit GC0000000000GRS [...]... locations, please refer to our website ADC Telecommunications, Inc., P.O Box 1101, Minneapolis, Minnesota USA 55440-1101 Specifications published here are current as of the date of publication of this document Because we are continuously improving our products, ADC reserves the right to change specifications without prior notice At any time, you may verify product specifications by contacting our headquarters . ClearGain ® Ground-Mounted Amplifiers 2/08•105192AE ClearGain ® Ground Mounted Aplifiers 4 www.adc.com • +1-952-938-8080 • 1-800-366-3891 ClearGain ® Ground-Mounted. arack,ClearGainPDUsprovidepowerandalarmingforADC’s ground-mounted amplifiers. Features: • Providespowerandalarmfunctionsforon-sitemonitoringofGroundMount Amplifiers (GMAs) •

Ngày đăng: 10/12/2013, 18:15

Tài liệu cùng người dùng

Tài liệu liên quan