The IS Control Operating Manual IS 600 and IS 500 IS 600 Control: For clear and easy muliple operation of up to appliances IS 500 Control: For practical single appliance operation Page Operating Manual IS 600 and IS 500 Contents Glossary Control Units IS Opening and closing the door Appliance Operation Operation 1.1 Manual Baking / Finish Baking 1.2 Baking Program / Finish Baking 1.3 Cleaning 10 1.4 Cool Down Program 11 Programming 12 2.1 Program Operation 12 2.1.1 Baking Step „edit“ 13 2.1.2 Baking Step „copy“ 14 2.1.3 Baking Step „move“ 14 2.1.4 Baking Step „delete“ 14 2.4 Delete Program 15 2.2 Copy Program 15 2.3 Move Program 15 Settings 16 3.1 Automatic Start 16 3.2 Pictogram Mode 18 3.3 Setting Time 18 3.4 System Settings 19 3.4.1 Pin Code Setting 19 3.4.2 Program Change 19 3.4.3 Country Setting 20 3.4.3.1 Language 20 3.4.3.2 Temperature 20 3.4.3.3 Time Format 21 3.4.4 Appliance Management (only for IS 600 Multiple appliance operation) 21 3.5 Aplliance Settings 21 3.5.1 Display 22 3.5.2 Ringer 22 3.5.3 Light 23 3.5.4 Factory Settings 24 3.6 Switch Code 25 3.6 Cleaning of Door ( only in DIBAS functions ) 25 4.0 Shutting off the appliance 25 Mulitple Applianace Operation (only possible withIS 600) 26 Operating a Poorfer with IS 500 / IS 600 27 4.1 Proofing Manual 27 4.2 Proofing Program 28 Programming Self Cleaning Program - Pro Clean 29 What do when ? 31 Warranty 32 Operating Manual IS 600 and IS 500 Page Glossar - Zeichenerklärungen und Abkürzungen Symbols Warning ! Danger sign Disconnect cable ! Unplug appliance for at least minutes until all electrial components are discharged Do not spray with water ! This sign advises to keep part away from water Attention hot surface ! Burn danger by means of hot surface Hot substances ! Burn dagner by means of hot substances Information Tip Read Operating Manual thoroughly IS Control abbreviations AbbreviationMeaning A Sink Process ATV Cascade B-ART Operation Mode D Drehzahl D Delta Process D Steam F Moisture HEI Convection Air HL Convection Air K Core Process KO Combi Steam OH Top Heat PCL Cleaning PRG Running Program S Step SCHW Steam UCL Cleaning UH Bottom Heat VER Process VH Preheat VO Preheat Z Time Process Page Operating Manual IS 600 and IS 500 IS Control Units The IS Control 600 / IS Control 500 Operation of the IS Control is user-friendly: The display function guides you through the menu To choose the appropriate menu function, turn the Selection select/confirm „W“ dial When the desired function has been reached, press the select/confirm „W“ to confirm selection Did you choose the wrong function? No oproblem! Simply press the „C“ key to return to the Start menu Please note the help text on the right side of the IS 600 Control display Short texts will additionaly guide you throught the program IS 600 individual Logo Display internal number of currently controlled appliance Current date and time 15:00 21.06.04 current device work menu will be displayed Correction key „C“ Jog dial for selection/ confirmation „W“ Help window Door „open/close“ key Only functions in appliances with electric door operation IS 500 Display individual Logo Correction key „C“ Jog dial for selection/ confirmation „W“ Operating Manual IS 600 and IS 500 Door „open/close“ key Only functions in appliances with electric door operation Page Operation Opening and closing the door The key door „open/close“ is used to open the oven door Press the key until the door automatically opens Warning! Steam and heat will escape upon door being opened Burn risk! Despite all safety precautions, it is unavoidable that steam and heat will escape upon the door being opened after use Futhermore, the glass and frame of the door become hot during oven operation Always wear safety gloves when opening the door! door „open / close“ key To close the oven door press the „door open/close“key until the door closes automatically THe“door open/close“key does not funtion in appliances without electric door operation In this case, open and close the door by using the door handle Operation: The „door open/close“ key does not function in appliances without electric door operation In this case, open and close the door by using the door handle Operation: To start the appliance press the „select/confirm W“ dial for at least seconds The display will show the Operations menu From this menu, the desired baking process can be started By pressing the „C“ key, you can return to the main menu Main Menu Work Programming Settings Switch off appliance 11:56 current device 21.06.04 work menu is displayed The following options are possible in the main menu: Work Programming Settings Switch off appliance By turning the select/confirm „W“ dial it is possible to highlight the desired function By pressing the select/confirm „W“ dial, the operator can then enter the selection Work Work MANUAL 001 BUNS 002 PRETZELS 003 PASTRY 004 CRUNCHIES 005 CLEANING 11:56 Current deevice 21.06.04 Choose program Press enter to tart In this menu the options: 1.1 Manual Baking 1.2 Baking Program X 1.3 Cleaning and 1.4 Cool Down can be accessed Page Operating Manual IS 600 and IS 500 Manual Baking 1.1 Manual Baking The example below shows a DIBAS appliance Manual Baking The example below shows an EBO appliance Manual Baking Start Preheating temperature 180°C Baking temperature 160°C Baking time 10 Air Intake/Extraction open fan speed Steamer Start Preheat temp top Preheat temp bottom Baking temp top Baking temp bottom Baking time Air Intake/Extraction Steamer 11:56 11:56 Current device 21.06.04 Start Program Current device 21.06.04 180°C 180°C 160°C 160°C 10 open Start Program The Baking process can be manually entered here Choose the desired baking step-e.g preheting by turning the select/confirm „W“ dial Confirm the choice by pressing the select/ confirm „W“ dial The display will show the entry field for the preheating temperature Choose the appropriate temperature-e.g 230°C by turning the „W“ dial and confirm your choice by pressing the „W“ dial Turning the „W“ dial again will jump the display to the next parameter Always choose the desired parameter by turning the „W“ dial and confirm your choice by pressing the „W“ dial After choosing and confirming the last parameter, leave the parameter by pressing the „C“ key The baking process can now be started by confirming the „Start“ parameter Please note that not all menu choices are available for each applicance type and control After the desired preheating temperature has been reached, the operator will be given an acoustic siganal The signal can be set by the operator in the Settings menu (main menu) The display will now show „please load oven“ The example shows a The example shows an DIBAS appliance EBO appliance Preheating TARGET ACTUAL 180°C 180°C INFO ! Preheating ended Please load oven 11:56 Current device 21.06.04 Preheating Top Heat Bottom Heat 180°C 180°C INFO ! Preheating ended Please load oven Manual Baking 11:56 Current device 21.06.04 Manual Baking Load the oven as quickly as possible in order to maintain the oven temperature Operating Manual IS 600 and IS 500 Page Manual Baking and Continue Baking Preheating TARGET ACTUAL 180°C 180°C Continue Baking? yes no 11:56 Current 21.06.04 device Manual Baking After loading the oven and shutting the door the display will ask if you want to continue baking? yes or no To continue baking press the select/confirm „W“ dial To end the baking process choose and confirm the no parameter with the select/confirm „W“ dial This example shows a DIBAS appliance Man DIBAS Actual-Temperature 160°C Remaining time 008 11:56 Current device 21.06.04 Manual Baking This example shows an EBO appliance Man EBO Top heat 160°C 160°C Bottom heat Remaining time 008 11:56 Current device 21.06.04 Manual Baking The actual temperature and remaining baking time is shown in the display By pressing the jog dial it it possible to steam your baking goods at any time The steaming process lasts for as long as the dial is pressed At the end of the baking process an acoustic signal will be given The display will show the baking time has ended and the choice to continue baking To end the baking process place the parameter to „end“ and press the jog dial to confirm your choice Continue Baking This shows an example for the DIBAS Man DIBAS Man DIBAS Baking Process ended Baking process ended End Continue Baking Remaining time End Continue Baking 11:56 Current device 21.06.04 Manual Baking 11:56 21.06.04 Current device 1 Manual Baking If you wish to extend the baking process you can so by selecting „continue baking“ with the jog dial „W“ Set the amount of minutes by turning the jog dial Press the jog dial to start the continue baking program The display will show the new remaining baking time At the end of the baking time the display will show baking process ended and the choice to once again continue baking To end the baking process select „End“ with your jog dial and confirm your choice by pressing the jog dial Page Operating Manual IS 600 and IS 500 Baking and Baking Programs Open the door by pressing the key „door open/close“ Unload the oven and close the door by pressing the „door open/close key once more Warning! steam and heat will escape upond door being opened Burn risk! The door open/close key does not function in appliances without electric door operation In this case, open and close the door by using the door handle 1.2 Baking Program X If a preset baking program is choosen, enter the preheating parameter The oven will then automatically heat to the required temperature Work MANUAL 001 BUNS 002 PRETZELS 003 PASTRY 004 CRUNCHIES 005 CLEANING 11:56 Current devicel 21.06.04 Choose program Press start to enter Work MANUAL 001 BRÖTCHEN INFO ! 002 BREZELN Preheating ended 003 PLUNDER Please load oven 004 KNACKIES 005 CLEANING 11:56 Current device 21.06.04 When the preheating temperature has been reached the display will show „Preheating finished, please load oven“ The operator will be alerted by an acousitc signal which can be individually programmed in the settings menu ( main menu ) Load the oven as quickly as possible to maintain the oven temperature Start the baking proceess by pressing the select/confirm „W“ dial The display will ask if you want to continue the program No will end the program Yes will run the pre-set baking program automatically The display will show the actual temperature and theh remaining baking time This is an example of an EBO appliance Buns Buns Top heat 160°C 160°C Bottom heat Remaining time 008 11:56 Current device 21.06.04 Baking ended End Continue baking 11:56 Current device 21.06.04 The baking program can be exited at any time by pressing the „C“ key At the end of the baking program time the operator will be alerted by an acoustic signal The display will show baking ended If needed you can continue baking End the baking process by selecting „end“ with the jog dial and confirm by pressing the jog dial Operating Manual IS 600 and IS 500 Page Automatic Self Cleaning 1.3 Cleaning Please note that the cleaning program will only run after the oven has cooled to 60 °C or below If the oven is too hot the the automatic cool down program should be started so that the wax seal of the cleaning cartridges will not melt before the cleaning process starts Important! Before operating the automatic cleaning system, please read the appropriate Operating Manual and inform all operating personnel The cleaning program is factory pre-set to Heavy Should you require a different setting or wish to program all three settings, this is possible in the „program“ parameter Please see the chapter „Programming“ for step by step instructions Example shows DIBAS appliance Work MANUAL 001 BUNS 002 PRETZELS 003 PASTRY 005 CLEANING 006 COOL DOWN 11:56 Current device 21.06.04 Choose program Press enter to start Cleaning Actual Temperature 30 °C Pro Clean is running Termination possible 11:56 Current device 21.06.04 Please note that the automatic cleaning program only works in appliances with this option In the cleaning parameter the fully automatic cleaning system PRO CLEAN can be started Go to the cleaning parameter and confirm the entry by pressing theh select/confirm „W“ dial The cleaning process will start immediately The program can be terminated at any time by pressing the „C“ key Example shows DIBAS appliance Cleaning Cleaning Actual Temperature Actual Temperature End programm? 30 °C No Pro Clean is running Yes 060 Termination possible 11:56 Current device 21.06.04 30 °C automatic rinse cycle is running 11:56 023 Current device 21.06.04 After pressing the „C“ key to exit the cleaning program, you will be asked once again if you really wish to stop the current program If you wish to stop the program press the „W“ dial Page 10 Operating Manual IS 600 and IS 500 Pictogram and Time Setting 3.2 Pictogram Settings Settings Pictograms Text depiction Picto depiction Text & Picto Autostart Pictograms Time Setting System Setting Appliance Setting Switch Code Door Cleaning for 11:56 current setting the text and device 21.06.04 11:56 Current device 21.06.04 picto depictions text will only be shown In this function the display illustrations can be chosen Choose between: Text depiction Picto depiction (only pictograms) Text & Picto (text and pictograms) Select mode by using the select/confirm dial Enter your selection and leave the menu at the same time by pressing the the select/confirm dial The entries are now saved 3.3 Setting Time Settings Autostart Pictograms Time setting System Setting Appliance Setting Switch code Door cleaning for 11:56 Current setting hour, date 21.06.04 device daylight saving time Settings Daylight saving Settings Set time Daylight savingtime set hour / date off on 11:56 11:56 Current device 21.06.04 set daylight saving time onoff Current device 21.06.04 To set the daylight saving time function press the select/confirm „W“ dial If the clock should be set to dayliight savings time select „on“ with the select/confirm dial and press to confirm If daylight savigs time should be shut off select„off“ with the select/confiirm dial and press the dial to confirm Settings Set time Daylilght Saving set hour/date Settings Set clock Hour Minutes Day Month Year Settings Set clock Hour Minutes Day Hour Month Year 10 11:56 11:56 11:56 current device 21.06.04 set time and date current device 21.06.04 current device 21.06.04 Set the actual time by selecting the hour, minutes, day month and year as well as the date with the help of the select/confirm „W“ dial To leave the program at any time use the „C“ key All entrys will automatically be saved If the power has been disconnected for a longer period of time you may have to reset the date and time Page 18 Operating Manual IS 600 and IS 500 PIN Code Setting and Program Change 3.4 System Settings Choosing the function „Settings“ will allow you to reach „System Settings“ which is divided as follows: Settings Autostart Pictograms Time Setting System Settings Appliance Settings Switch Code Door Cleaning for 11:56 Current Setting the systems 21.06.04 device pin code administration 3.4.1 Pin Code Setting 3.4.2 Program Change 3.4.3 Country Setting 3.4.4 Appliance Management 3.4.1 PIN Code Setting Settings Pin Code Setting System Settings Pin Code Setting Program Change Country Setting ApplianceManagement 0123456789 11:56 11:56 Current device 21.06.04 Back Return Current device 21.06.04 set pin code set pin code Use this function to program the individual pin number of the appliance Enter your personal pin number by using the select/confirm dial Please note that only PIN codes that have a value of at least 1000 are valid The PIN Code is now permanently saved and closes the admittance to the systems settings If the PIN Code should be deleted or changed the current PIN Code must be entered first in order to make any changes to the systems settings program To delete the current PIN Code, first select the arrow „back“, confirm the selection and then select the „return“ arrow Confirm the entry by pressing the dial It is now possible to access the systems settings again 3.4.2 Program Change System Settings System Settings System Settings Pin Code Setting Program Change Country Setting ApplianceManagement Program Change Programming running program Programming Yes No 11:56 11:56 11:56 Current device 21.06.04 user options Set Programs ? Current device 21.06.04 Programs may be edited Current device 21.06.04 Programs may be edited Here you can interrupt pre set programs Whether new programs should be programmed or running programs should be interupted Setting „Yes“ => entry permitted to everyone Setting „No“ => entry permitted only with PIN Code (a pin code must be programmed for this) Operating Manual IS 600 and IS 500 Page 19 Country Setting / Language / Temperature 3.4.3 Country Setting This function is further divided as follows: System Settings Country Setting Pin Code Setting Program Change Country Setting ApplianceManagement Language °C or °F Time Format 11:56 11:56 Current device 21.06.04 Setting for language, temperature and time Current device 21.06.04 choose language 3.4.3.1 Language 3.4.3.2 °C or °F 3.4.3.3 TimeFormat 3.4.3.1 Language Used to choose between two factory programmed languages For example factory setting „Language1“ => German and „Language 2“ => English Country Setting Select language Language °C or °F Time Format Language Language 11:56 Current device 21.06.04 select language 11:56 Current device 21.06.04 Choose language by using the select/confirm dial Confirm choice by pressing the dial The selected language is now permanently set ATTENTION! It is possible to have other languages programmed on your IS Control Please ask our Customer Service Department 3.4.3.2 Temperature With this function the operator has the possibility to switch between Celsius and Fahrenheit degrees Country Setting Temperature Language °C or °F Time Format °C °F 11:56 Current 21.06.04 device select temperature 11:56 Current device 21.06.04 Set the parameter by turning the select/confirm dial to the desired temperature unit and press the dial to set the desired temperature unit The newly set temperature unit is now saved Page 20 Operating Manual IS 600 and IS 500 Time Format / System Settings 3.4.3.3 Time Format Country Setting Time Format Language °C or °F Time Format 11:56 Current device 21.06.04 24-h clock 12-h clock 11:56 Current device 21.06.04 time format display 24h12h „Time Format“ is used to switch between the 24-hour clock and the 12-hour clock Select by turning and pressing the select/confirm „W“ dial The chosen setting is automatically activated 3.4.4 Appliance Management (only for use with IS600 mulitple operations appliances ) Settings Set Pin Code System Settings Pin Code Setting Program Change Country Setting 0123456789 Appliance Management 11:56 Current device 21.06.04 back return 11:56 Current Device 21.06.04 set appliance management Activate Parameter set appliance management Activate Parameter „Appliance Mangement“ can only be accessed after entering a valid PIN code for the specific appliance The various CAD-adresses can be assigned and the appliances can be activated or deactivated We recommend that this function only be carried out by authorized service partners, since even the slightest false settings in this function may cause a disruption to the complete running program 3.5 Appliance Settings Settings Autostart Pictograms Time Setting System Setting Appliance Setting Switch Code 11:56 Current Device 21.06.04 Appliance Setting for Gong,light door Settings Display Ringer Light Factory Settings 11:56 Current Device 21.06.04 Setting for Logo and contrast 3.5.1 Display 3.5.2 Ringer 3.5.3 Light 3.5.4 Factory Setting The function „Appliance Settings“ is divided into the following: display, ringer, light, factory setting and door Indidvidual settings can by changed and reset Operating Manual IS 600 and IS 500 Page 21 Display / Ringer 3.5.1 Display Appliance Settings Display Ringer Light Factory Settings 11:56 Current device 21.06.04 Appliance Settings Logo Selection Display Logo Logo selection Contrast setting for logo and contrast 11:56 Current device 21.06.04 Appliance Settings Logo picture choice for screen saver 11:56 Current Device 21.06.04 picture choice for screen saver The function „Display“ is further divided into „Logo selection“ and „Contrast“ Select your individual logo that should appear in the display as a screen saver by using the select/confirm dial Press the dial to confirm choice Our authorized service partners can program your individual company’s symbol in the display for you Appliance Settings Appliance Settings Display Contrast Logo selection Contrast -3 11:56 Current device 21.06.04 contrast selection 8=dark -8=light 11:56 Current device 21.06.04 contrast selection 8=dark -8=light The function „contrast“ can change the display screen contrast You can choose the contrast by turning and pressing the select/confirm dial from -8 (very light) to (dark) The selection will be saved 3.5.2 Ringer Ringer Appliance Settings Display Ringer Light Factory Settings 11:56 Current Device 21.06.04 Setting for ringer, Ton, volume Ringer Volume Volume Interval Ton 11:56 Current device 21.06.04 250 set volume = quiet 11:56 Current device 21.06.04 set volume = quiet In the function „Ringer“ the following Ringer Settings are possible.: Volume, length of Interval and acoustic signal Set the appropriate volume by placing the parameter on „Volume“ and turn the dial to the required volume (0 = off and 250 = loud ) Press the dial to confirm choice Page 22 Operating Manual IS 600 and IS 500 Light Ringer Ringer Interval Volume Interval Ton 11:56 Current Device 21.06.04 11:56 Current device 21.06.04 set length of interval 10 Min set length of interval 10 Min In the function „Interval“ the time can be entered in minutes for how long the acoustic signal should be heard for Enter by using the select/confrim dial the time from between - 10 minutes After confirming the selection by use of the select/confrim dial the entry will be saved Ringer Ringer Ton Volume Interval Ton 11:56 Current device 21.06.04 11:56 Current device 21.06.04 Set acoustic signal = bell ring = bell ring Set acoustic signal = bell ring = bell ring In addition you can choose between 1,2, and bell-ringers in order to differentiate between machines in a multiple systems operations 3.5.3 Light Appliance Settings Display Ringer Light Factory Settings 11:56 Current device 21.06.04 light setting Appliance Settings Appliance Settings Light preheating flash pre heating flash Program flash Yes No 11:56 Current deevice 21.06.04 flash after preheating Yes No 11:56 Current device 21.06.04 flash after preheating yes No Iin the appliance settings „Light“ it is possible to set an optical signal to show that the preheating temperature has been reached or the baking program has ended Place the parameter to „Light“ and confirm as usual by pressing the dial If the oven should flash after reaching the pre heat temperature then select „Yes“ and confirm your selection by pressing the dial Then entry will then be saved Operating Manual IS 600 and IS 500 Page 23 Factory Settings / Door Appliance Settings Appliance Settings Light Flash at end of prog Flash at end of VH Flash at end of prog yes No 11:56 Current device 21.06.04 flash at program end yes no 11:56 Current device 21.06.04 Flash at program end yes No In addition an optical signal can be given at the end of the program Select the parameter „Flash at end of prog.“, Select „yes“ by pressing the select/confirm dial and your entry will be saved 3.5.4 Factory Settings Appliance Settings Display Ringer Light Factory Settings 11:56 Current device 21.06.04 Setting for ringer, Ton, volume In the function „Factory Settings“ you can reset various factory settings for example the ringer, light and display Please note that once this function and been selected and entries confirmed all previous settings will be void Page 24 Operating Manual IS 600 and IS 500 Switch Code / Door Cleaning / Shut off appliance 3.6 Switch Code Settings Autostart Pictograms Time Setting System Settings Appliance Settings Switch Code Door Cleaning 11:56 Current device 16.7.02 The switch code enables the oven or the complete system to block or unblock 3.6 Cleaning of Door (only in applianaces with DIBAS ) Settings Autostart Pictograms Time Setting System Settings Appliance Settings Switch Code Door Cleaning 11:56 Current set door in 21.06.04 device forward mode (Cleaning) Use this function to open the door to the so called cleaning position Select by using the select/ confirm dial and confirm choice by pressing the dial The door will open slightly automatically The door can be slanted by using the door release Please read more about this function in the DIBAS Operating Manual, chapter „Manual Cleaning and Care“ 4.0 Shutting off the Appliance Main Menu Work Programming Settings Switch off appliance 11:56 Current device 21.06.04 Should the oven be switched off then select the function „Switch off appliance“ by using the select/confirm dial The oven will go into the Stand By Mode Please note that in multiple operations each oven must be individually controlled and switched off Operating Manual IS 600 and IS 500 Page 25 Multiple Appliance Operation Mulitple Appliance Operation (only possible with the IS 600 Control) With the IS 600 Control it is possible to operate up to different appliances If your ovens are connected and operated by an IS 600, all appliances will be shown in the display Select appliance Appliance Appliance Appliance Appliance 11:56 Current device 21.06.04 Select appliance Select Appliance EBO top EBO middle EBO bottom Proofer Dibas top Dibas bottom Proofer 11:56 Current device 21.06.04 11:56 Current device 21.06.04 To remember what appliance or proofer is hidden behind each description of Appliance 1, Appliance etc your Service Partner can program an oven description applicable for each text Each oven using the IS Control can be switched on, switched off and controlled In every situation you can access each program an view the appliances By pressing the „C“ key for at least seconds an illustration will appear in the display Select appliance EBO top EBO middle EBO bottom Proofer 11:56 Current device 21.06.04 Select appliance EBO top EBO middle EBO bottom Proofer 11:56 Current devicel 21.06.04 So that you know which oven is currently being operated by you the diplay will show „Current device“ Each applicable number will be shown Many of the functions explained in this operating manual are for multiple appliance operations Remember before operating theh oven that you have selected the correct appliance Do not forget that all appliances in the system must by individually switched off By pressing the „C“ key the oven will go into the energy saving mode Page 26 Operating Manual IS 600 and IS 500 Additional Appliance Proofer Operating a proofer IS 500 / IS 600 Main menu Manual 001 Proofer Prog 002 Proofer Prog 003 Proofer Prog 11:56 Current device 21.06.04 select program Choose between: 4.1 Proofing Manual and 4.2 Proofing Program X 4.1 Manual Proofing Here you can manually enter the proofing operation Proceed as usual Manual Proofing Start Temperature Moisture Proofing time 11:56 Current device 21.06.04 35°C 99 % 10min set proofing time in ins Manual Proofing Start Temperature Temperature 35°C 45 Moisture 99 % Proofing time 10min 11:56 Current device 21.06.04 set proofing time in mins Choose by turning the select/confirm „W“ dial each function for example „Temperature“ Confirm the selection by pressing the „W“ dial The display will show the entry field for the proofing temperature Set the temperature for example 45°C, by turning the „W“ dial and confirm the choice by pressing the select/confirm „W“ dial By turning the select/confirm dial the parameter will go to the next function Manual Proofing Start Temperature Moisture Proofing time 11:56 Current device 21.06.04 45°C 99 % 10min set moisture in % Manual Proofing Start Temperature Moisture Proofing time 11:56 21.06.04 Current device 45°C 85 % 10min Set proofing time in mins Select all parameter entrys this way that need to be changed Always confirm your choice by pressing the“W“ dial The proofing process will begin by pressing the „START“ function Please note: The entry values for the proofing temperatures are between 20°c and max 45°C The moisture can be set from 50% and max 85% Operating Manual IS 600 and IS 500 Page 27 Additional Appliance Proofer Load the proofer as quickly as possible to prevent heat from escaping the proofer chamber The proofer heats using the pre-set temperature, and the remaining time will be shown on the display Manual Proofing Start Temperature Moisture Proofing time 11:56 Current 21.06.04 Device 45°C 85 % 20min set proofing time in mins Proofer RequiredTemperature 45 °C Moisture 85 % Remaining time 020 11:56 Current 21.06.04 device At the end of the proofing process, the operator will be given an acousic signal The signal can be individuaoly programmed at the operating level „Settings / Appliance settings.“ Proofer Soll-Temperatur Proofing 45 °C completed.Please Feuchte unload chamber 85 % Remaining time 000 11:56 Current device 21.06.04 Proofer Programm beenden Nein Ja Remaining time 000 11:56 Current device 21.06.04 Additionaly the display will indicate that the proofing time has ended Proofing completed, please unload chamber“ will appear The running proofer program can be terminated at any time by pressing the „C“ key The display will ask if you would like to end the runningn program By turning the select / confirm „W“ dial you can choose your answer Yes/No and confirm the choice by pressing the „W“ dial 4.2 Proofing Program X When a pre-set proofing program is chosen, the proofer will alutomaticallhy start by using the specified temperature and moisture settings The remaining time will be shown on the display The programming and settings of the appliance will, as usual, be controlled in the main menu See previous chapters for details A running program can be terminated by shortly pressing the „C“ key Furthermore, the IS 600 can be hooked up to a visual display counter which informs the operator of upcoming ending programs Page 28 Operating Manual IS 600 and IS 500 Programming ProClean Progamming the fully automatic self cleaning ProClean This function is only possible in ovens that have the self cleaning system ProClean Just like programming baking programs in this function for the self cleaning program you can edit, copy, move and delete.If you wish to change the facotry settings select „edit“ Confirm your selection by pressing the select/confirm „W“ dial Programming 051 CLEANING 052 053 054 055 056 COOL DOWN 11:56 Current device 21.06.04 select program Programming 001 BUNS edit 002 PREZELS copy 003 CROISSANT move 004 PASTRY 005 REINIGUNG delete 006 Cool Down 11:56 21.06.04 Current device use program parameter First the program name will be asked for If this should not be changed then turn the „W“ dial further If you wish to change the name of the cleaning program confirm your selection by pressing the dial Enter the program name as usual by turning ( to select ) and pressing ( to confirm) Save the name by selecting and pressing the „return“ symbol Programming Programming CLEANING CLEANING light S B-Art °C Air D S B-Art °C Air D Picto No.: 05 PCL 11:56 heavy Current device 21.06.04 Picto No.: 05 enter program name PCL 11:56 21.06.04 heavy Current device enter program name The next step will ask for the pictogram number If you use your oven in the pictogram mode you have the possibilty to use the same symbol for the cleaning program Programming CLEANING light PcktoOperation No.: 05 Mode Pre-heating S B-Art °C Luft D Proclean PCL 11:56 21.06.04 stark Current device enter program name Now the programming steps will be asked for The steps can be inserted, copied, moved or deleted, When programming the cleaning program this step can be skipped If you have mistakingly chosen a step then turn the jog dial and select the next procedure „Operation Mode“ Operating Manual IS 600 and IS 500 Page 29 Programming ProClean To program the cleaning process select „Pro Clean“ and confirm by pressing the select/ confirm dial At the end the cleaning level will be asked for There are three cleaning levels and a cool down program to choose from Programming CLEANING light Pikto Operation Nr.: 05 Mode Preheat S B-Art °C Luft D Proclean PCL 11:56 21.06.04 stark Current device Programming light middle heavy cool down 11:56 21.06.04 Current device dirt level Confirm your selection by pressing the select/confirm „W“ dial To leave the programming mode press the „C“ key The display will ask „save changes“ if the changed enteries should be saved Programming CLEANING Pikto Nr.: 05 Save changes? S B-Art °C Luft D Yes No PCL 11:56 21.06.04 stark Current device Make selection and confirm your entry by pressing the select/confirm „W“ dial If you want to add the cleaning program to an additional appliance in your work menu then select the function „copy“ You can hereby copy the existing program to the desired position Copy and change the name and cleaning level as required as described in the previous paragraph „programming the self cleaning Pro Clean“ Work 051 CLEANING 052 CLEANING 053 CLEANING 054 055 056 COOL DOWN 11:56 21.06.04 Current device Select program Use these steps to individualize your cleaning programs Please read the operating instructions for the automatic self cleaning system Pro Clean Instruct your operators and please note all the warnings and saftey notices Page 30 Operating Manual IS 600 and IS 500 What to when ? In the following list you will find various failure messages that can appear in the display of the IS Control Please note all safety notices that refer to your oven Always unplug the oven or proofer before starting any reapairs If the message in the display reads „disconnet mains plug“ , it means that the oven or proofer must be unplugged Please wait minutes before plugging the appliance back in to the mains so that all electrical components are discharged Please make sure the oven has cooled down before starting any repairs Otherwise there is a burn risk due to the hot surfaces! What to when ? IS INFO Cause CLOSE DOOR BEFORE STARTING PROGRAM Open door Door switch is defective False systems configuration Close door Customer Service Control systems configuration if need be Customer Service TEMPERATURE FAILURE! BOILER, ATV….PROBE TOO HOT, TOO COLD… CLOSING, BREAK Customer Service + Room temperature is too hot unplug Customer Service MOTOR IS TOO HOT Motor is mechanically blocked Motor is defective STEAMING FAILURE! TOO LITTLE / NO WASSER Water flow is not open Magentic ventil is defective Plugged steamer jet check Customer Service check Customer Service Check if needed customer service FAILURE ! DOOR FAILURE DOOR TIMEOUT Door is mechanically blocked Door Motor is defective check Customer Service Plugged Drain Magnetic ventil id defective Pressure Switch is defective Water line is not open Dirt filter is plugged Boiler is calcified Water is too soft Line power < 180µS 1.no power 2.Control is internally blocked Data line is damaged Operating part is too hot Contrast is set false check Customer Service Customer Service check Customer Service Decalicify /Customer Service Ask Water Company /Customer Service FAILURE ! OVER PRESSURE INFO! BOILER FAILURE BOILER IS EMPTY Display is dark Corresponding probe is defective Control is too hot Operating part is too hot Internenal control blockage Operating Manual IS 600 and IS 500 Corrective Action check Customer Service Customer Service Room temp is too hot, unplug 5.check / customer service Page 31 Warranty and Copyright Warranty: For warranty conditions please refer to our General Terms of Business When making a warranty claim, please be sure to the following: 1.) To ensure the quick and efficient handling of your claim, please tell us the exact designation of our oven It can be found on the rating plate, which is mounted on either the left of right side of your oven 2.) Please give us the serial number of your oven, which can be found on the front face of the oven when the door is open 3.) Please clean the oven before warranty repairs are carried out 4.) Please advise us of any complaints you may have We thank you in advance for observing the above items, which help us to process and repair any malfunctions as quickly and efficiently as possible This document has been created with care and designed to make the use of the corresponding baking oven system as user-friendly as possible Nevertheless, discrepancies or errors cannot be completely excluded WIESHEU GmbH accepts neither legal responsibility nor liability of any kind for any incorrect information or the consequences therof We reserve the right to make technical changes or changes to the external apearance of the appliance We would appreciate any comments regarding errors in the text or illustrations Copyright WIESHEU GmbH retains the copyright to these operating instructions This operating manual is intended solely for the user and the user’s employees The rules and instructions it contains may not be reproduced, distributed, or similarly passed on to third parties Violators may be subject to criminal penalties WIESHEU GmbH Daimlerstrasse 10 71563 Affalterbach Printed in Germany We reserve the right to make technical changes in the interest of progress and quality improvement Operating Manual for the IS Control Order number 102856 Version 1.06 Level : 01.2009 Page 32 Operating Manual IS 600 and IS 500 ... Time Process Page Operating Manual IS 600 and IS 500 IS Control Units The IS Control 600 / IS Control 500 Operation of the IS Control is user-friendly: The display function guides you through... BOILER FAILURE BOILER IS EMPTY Display is dark Corresponding probe is defective Control is too hot Operating part is too hot Internenal control blockage Operating Manual IS 600 and IS 500 Corrective... filter is plugged Boiler is calcified Water is too soft Line power < 180µS 1.no power 2 .Control is internally blocked Data line is damaged Operating part is too hot Contrast is set false check Customer

Ngày đăng: 13/03/2019, 19:26

Từ khóa liên quan

Tài liệu cùng người dùng

Tài liệu liên quan