Commissioning CNODE and OMS800

60 331 0
Commissioning CNODE and OMS800

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

Thông tin tài liệu

INDEX I TRANSMISSION CNODE AND OMS800 2 A. MW Download_Upload Database on CNODE via CID 2 B. MW Bypass Cnode Equipment 5 C. MW Bypass OMS800 Equipment 9 D. Replace Faulty Card of OMS800 Equipment 15 E. Setup IP OMS800 Instruction 23 F. Backup Restore OMS800 Configuration 27 II TRANSMISSION SDH 41 A. Replace Faulty TRX of MDRS Equipment 41 B. How to Adjust a SDH Hop 49 III NETWORK DIAGRAM 58 IV REVISION HISTORY 60

Site Check Instruction Ericsson Confidential WORKING INSTRUCTIONS Prepared (also subject responsible if other) (60) No FM South Team For Ref Only Checked Date Rev 2010-06-14 PA1 Reference INDEX I TRANSMISSION CNODE AND OMS800 A MW Download_Upload Database on CNODE via CID B MW Bypass Cnode Equipment C MW Bypass OMS800 Equipment D Replace Faulty Card of OMS800 Equipment 15 E Setup IP OMS800 Instruction 23 F Backup & Restore OMS800 Configuration 27 II TRANSMISSION SDH 41 A Replace Faulty TRX of MDRS Equipment 41 B How to Adjust a SDH Hop 49 III NETWORK DIAGRAM 58 IV REVISION HISTORY 60 Site Check Instruction Ericsson Confidential WORKING INSTRUCTIONS Prepared (also subject responsible if other) (60) No FM South Team For Ref Only I Checked Date Rev 2010-06-14 PA1 Reference TRANSMISSION CNODE AND OMS800 A MW Download_Upload Database on CNODE via CID Description: This section describes how to download and upload database on CNODE via CID program Hướng dẫn cách dùng chương trình CID để download upload liệu thiết bị SDH CNODE Tool requirement: Tool preparation: RS232 console cable, USB-Com cable (for PC without COM port), CID software (see Annex for RS232 cable connection diagram) Dụng cụ: Dây cáp console RS232, cáp chuyển đổi từ USB sang COM (cho máy tính cổng COM), phần mềm CID (Sơ đồ cáp RS232 phụ lục đính kèm) Guideline: Step Action Connect RS232 console cable to Cnode on f interface Kết nối máy tính với Cnode vào cổng f a Startup CID: Click start > Program file > CID: Chạy chương trình CID máy tính b Choose COM and enter user/password to login: Chọn COM nhập vào user/pass c a Uploading Database to PC: Upload liệu từ CNODE lên máy tính: Site Check Instruction Ericsson Confidential WORKING INSTRUCTIONS Prepared (also subject responsible if other) (60) No FM South Team For Ref Only Checked Date Rev 2010-06-14 PA1 Reference From File menu select Database Upload/Download: - Click >> icon to choose all databases on the left of the Database Download dialog box Chọn biểu tượng >> để chọn upload tất liệu (bên trái hộp cửa sồ Database select) - On Operation field: Click “upload”, Click the Browse to choose the directory that is desired directory and click “start” to upload Chọn “Upload” vùng Operation chọn thư mục để lưu liệu, ‘Start” để upload b Downloading database to Cnode: Download liệu từ CID máy tính xuống thiết bị CNODE - Click the “Browse” to open the Work Path Select dialog box and choose which directory store database file Note: Restore data base must match existing equipment otherwise traffic will be lost Chọn vào phần Download nhấn “Browse” để mở hộp “Work Path Select” chọn thư mục lưu file backup máy tính cần download Note: Phải đảm bảo chắn file liệu lưu máy tính phải cho thiết bị không làm sai cấu hình thiết bị dẫn tới Site Check Instruction Ericsson Confidential WORKING INSTRUCTIONS Prepared (also subject responsible if other) No FM South Team For Ref Only Checked Date Rev 2010-06-14 PA1 Reference dịch vụ - Click SET button to complete downloading: Chọn “SET” để download - After downloading finish that reset CNODE Reset lại CNODE sau download xong Annex 1 2 3 5 6 7 f inferface RJ45 DB-9 Female Cabling diagram between CID and f port on CNODE Sơ đồ đấu cáp CID f port CNODE (60) Site Check Instruction Ericsson Confidential WORKING INSTRUCTIONS Prepared (also subject responsible if other) (60) No FM South Team For Ref Only Checked Date Rev 2010-06-14 PA1 Reference B MW Bypass Cnode Equipment Description: This section describes how to bypass CNODE equipment when it’s happened critical fault Hướng dẫn bypass thiết bị CNODE thiết bị xảy lỗi nghiêm trọng tre6n CNODE Tool requirement: Tools preparation: Small Phililps screwdriver and small flat head screwdriver Dụng cụ: (tua vít bốn cạnh tua vít dẹt loại nhỏ) Guideline Step Action Verify that optical jumper connections between Cnode and MDRS on ODF to make sure correct connection below: Kiểm tra jumper quang kết nối CNODE DMR 3000S ODF, bảo đảm kết nối a Diagram system MW Summary in site: Sơ đồ tổng quát trạm b Modules on CNODE: Các module kết nối quang CNODE Site Check Instruction Ericsson Confidential WORKING INSTRUCTIONS Prepared (also subject responsible if other) (60) No FM South Team For Ref Only Checked Date Rev 2010-06-14 PA1 Reference c ODF Frame: Tủ ODF Keep Coupler to spare Giữ cặp coupler để dự phòng d Optical jumper (Ref Topology: 236020): Chi tiết kết nối sơ đồ mạng (Tham khảo Site 236020) : Site 343008 – Site 236020 – Rep028 Bypass CNODE: Turn off CB on CNODE before performs bypass Tắt CB Cnode trước bypass thiết bị Case 1: Bypass direct on CNODE: Cách 1: Bypass trực tiếp Cnode o Put Tx optical jumper of MB1 to Rx optical jumper of SB1 on CNODE via coupler module and same for reverse direction (Rx to Tx) b/w MB1&SB1 on CNODE Đấu cable quang Tx MB1 qua cable quang Rx SB1 CNODE thông qua coupler Đấu ngược lại cho cặp cable quang Rx-Tx MB1 Site Check Instruction Ericsson Confidential WORKING INSTRUCTIONS Prepared (also subject responsible if other) (60) No FM South Team For Ref Only Checked Date Rev 2010-06-14 PA1 Reference SB1 lại MB1 CNODE SB1 CNODE MB1-Tx SB1-Tx MB1-Rx SB1-Rx SB1-Rx MB1-Tx SB1-Tx MB1-Rx Case 2: Bypass Cnode on ODF: Cách 2: Bypass Cnode ODF Step1: Jumper on CNODE Plug out optical jumper cable both Tx/Rx on upper of ODF in the MTSO direction Cnode: Rút cặp Tx/Rx cable quang khỏi đầu Coupler mặt ODF Step 2: Jumper on MDRS Plug out optical jumper cable both Tx/Rx on upper of ODF in the opposite direction MDRS: Rút cặp Tx/Rx cable quang khỏi đầu coupler mặt ODF Step 3: Bypass Cnode Put Tx jumper optical cable on Cnode (Labeled: MB-Tx) to Rx optical jumper cable on MDRS (labeled: OP-x-Rx) via coupler module and same for reverse direction (Rx cable to Tx) b/w CNODE and MDRS Đấu cable Tx (nhãn: MB-Tx) CNODE qua cable Rx MDRS (nhãn OPx-Rx) thông qua coupler Đấu ngược lại cho cặp cable Rx-Tx CNODE MDRS Site Check Instruction Ericsson Confidential WORKING INSTRUCTIONS Prepared (also subject responsible if other) (60) No FM South Team For Ref Only Checked Date Rev 2010-06-14 PA1 Reference CNODE MDRS MB-Tx OP1Tx MB-Rx OP1Rx OP1-Rx MB1-Tx OP1-Tx MB1-Rx Contact to Ericsson Support Team to check status sites after bypass CNODE If get new cnode, return connection and traffic on Cnode that Refer to ETV-OMF-TR-2005 to download files Liên hệ với đội Ericsson phụ trách kiểm tra trạng thái sites sau bypass CNODE Nếu nhận Cnode thực trả kết nối traffic trước tham khảo qui trình ETV-OMF-TR-2005 để download file cấu hình Site Check Instruction Ericsson Confidential WORKING INSTRUCTIONS Prepared (also subject responsible if other) (60) No FM South Team For Ref Only Checked Date Rev 2010-06-14 PA1 Reference C MW Bypass OMS800 Equipment Description: This section describes how to bypass OMS800 equipment when it’s happened critical fault Hướng dẫn bypass thiết bị OMS800 thiết bị xảy lỗi nghiêm trọng Tool requirement: Tools preparation: Small phililps screwdriver and small flat head srewdriver Tua vít cạnh tua vít dẹt lọai nhỏ Guideline Step Action Verify that jumper optical connection between OMS800 and MDRS on ODF to make sure correct connection below: Kiểm tra jumper quang kết nối OMS800 MDRS ODF, bảo đảm kết nối e Diagram system MW Summary in site: Sơ đồ tổng quát trạm f Modules on OMS800: Các module OMS800 Site Check Instruction Ericsson Confidential WORKING INSTRUCTIONS Prepared (also subject responsible if other) 10 (60) No FM South Team For Ref Only Checked Date Rev 2010-06-14 PA1 Reference g ODF Frame: Tủ ODF h Optical jumper: Quy luật đấu quang Luật 1: Nếu có ODF-OMS, mặt sau ODF-OMS kết nối với thiết bị OMS800, mặt trước ODF-OMS kết nối với thiết bị MDRS Site Check Instruction Ericsson Confidential WORKING INSTRUCTIONS Prepared (also subject responsible if other) 46 (60) No FM South Team For Ref Only Checked Date Rev 2010-06-14 PA1 Reference • Remove TRX fixing screws / Sử dụng vít lõm cạnh (cỡ 20) để mở vít cố định TRX Site Check Instruction Ericsson Confidential WORKING INSTRUCTIONS Prepared (also subject responsible if other) 47 (60) No FM South Team For Ref Only Checked Date Rev 2010-06-14 PA1 Reference • Replace the TRX unit / Tháo TRX hư thay TRX • Secure the TRX Unit using the fixing screws / Cố định TRX vít • Remount the cables (semi-rigid or semi-flexible (handformable))/ Gắn lại cáp semirigid • If applicable, connect the XPIC cabling / Gắn lại cáp XPIC có sử dụng • Mount the TRX cover / Gắn lại miếng nhựa che chắn bên ngòai tủ • Switch on the circuit breaker of the corresponding OP in the power box / Bật CB TRX tương ứng tủ phân phối nguồn Checking the System after Replacing a TRX / Kiểm tra lại hệ thống sau thay TRX Site Check Instruction Ericsson Confidential WORKING INSTRUCTIONS Prepared (also subject responsible if other) 48 (60) No FM South Team For Ref Only Checked Date Rev 2010-06-14 PA1 Reference • After the boot process, execute a TRX check using the LMT / Sau hệ thống khởi động xong, TRX nhận dạng, dùng chương trình LMT để kiểm tra • In an XPIC system, switch on the TX output power in the far end Đối với hệ thống có sử dụng XPIC, lúc thay ta tắt ngõ phát đầu xa (để tránh nhiễu kênh) Nên sau thay xong phải bật lại ngõ phát TRX đầu xa • Switch back to the OP and set the switch mode to ‘automatic’ on both sides Chuyển mạch lại ban đầu, thiết lập chuyển mạch OP TRX thay ‘automatic’ • Close the LMT session and power off the PC Thóat chương trình LMT tắt máy tính - Contact to Ericsson Support Team to check status sites after replacing new TRX of MDRS equipment Liên hệ với đội Ericsson phụ trách kiểm tra trạng thái sites sau thay TRX thiết bị MDRS - The faulty TRX must be returned to Ericsson for repair with a repair delivery note Include the clear description of the fault found TRX hỏng phải chuyển Ericsson để sửa chữa, bao gồm mô tả rõ ràng tình trạng lỗi Revision history Revision Draft Revised Approved Date 2010-06-08 Name Mac Quoc An Description 1st draft Site Check Instruction Ericsson Confidential WORKING INSTRUCTIONS Prepared (also subject responsible if other) 49 (60) No FM South Team For Ref Only Checked Date Rev 2010-06-14 PA1 Reference B How to Adjust a SDH Hop Description: This section describes how to adjust one SDH hop when have the adjusting requirement to increase RSL (Received Signal Level) as the designed RSL Hướng dẫn cách chỉnh tuyến SDH có yêu cầu chỉnh tuyến truyền dẫn SDH để mức tín hiệu thu đạt ngưỡng thu theo thiết kế Tool requirement: • • • • Multi-meter: to check RSL at TRX unit when choose Volt DC mode Multi-meter: dùng để kiểm tra mức thu TRX chọn chế độ đo DC role of electric wires, each role is about 100 meters long cuộn dây điện, cuộn dài khỏang 100m Computer with LMT cable: to check RSL by "LMT Maintenance Terminal MDRS 7.0 564" software Máy tính với cáp LMT, dùng để kiểm tra mức thu TRX phần mềm “LMT Maintenance Terminal MDRS 7.0 564” Tools to adjust SDH antenna in horizontal and vertical: Adjustable wrench, set of open Wrench, Pliers, Screwdriver, safety belt, helmet, compass (optional) … Các dụng cụ để chỉnh tuyến truyền dẫn SDH: cà lê, mỏ lết, kìm cắt, dây bảo hiểm, mũ bảo hộ, la bàn (tùy chọn)… Guideline Step Action First, make sure the opposite site have Power Transmission: +30dBm and Power Control mode: MTPC mode ( MTPC: Manual Transmit Power Control / deactive ATPC mode), we can check Tx level power control mode by LCT software When find out: this hop have RSL lower than designed + 5dbm (in good weather), we need to adjust antenna to meet designed RSL to prevent loss transmission when have big rain or strong wind To adjust MW antenna of SDH hop, we have main steps: Adjust antenna in horizotal Adjust antenna in vertical Đầu tiên, phải đảm bảo trạm đối diện phát với mức công suất tối đa +30dBm (bỏ chọn ATPC) Ta kiểm tra mức thu phát phần mềm LCT Khi phát tuyến truyền dẫn có mức thu thấp +5dBm so với thiết kế (trong điều kiện thời tiết tốt), ta cần chỉnh để mức thu đạt thiết kế đề phòng tránh truyền dẫn có mưa to, gió lớn Để chỉnh anten tuyến SDH, ta cần thực bước: Site Check Instruction Ericsson Confidential WORKING INSTRUCTIONS Prepared (also subject responsible if other) 50 (60) No FM South Team For Ref Only Checked Date Rev 2010-06-14 PA1 Reference Chỉnh anten theo hướng ngang Chỉnh anten theo hướng dọc • Connect the end of 1st electric wire role to port RSL RX (if we adjust for main antenna) or RSL RXD (if we adjust for diversity antenna) and another connected to port GND of MDRS rack Nối đầu cuộn dây vào ngõ RSL RX (nếu ta cần chỉnh trống chính) hay ngõ RSL RXD (nếu ta cần chỉnh trống phân tập), đầu cuộn dây lại ta nối tới cổng GND tủ MDRS • Other the end of the roles is took to tower and connected to Multimeter to monitor RX level of this SDH hop when antenna adjustment Các đầu lại cuộn dây đưa lên cột anten kết nối với Multimeter để giám sát mức tín hiệu thu trạm điều chỉnh anten Site Check Instruction Ericsson Confidential WORKING INSTRUCTIONS Prepared (also subject responsible if other) 51 (60) No FM South Team For Ref Only Checked Date Rev 2010-06-14 PA1 Reference • Check the tools and equipment needed before going up the tower Double check your safety belt if secured before using it Kiểm tra dụng cụ thiết bị cần thiết trước leo lên cột Kiểm tra kỹ dây bảo hiểm, đảm bảo an tòan trước sử dụng • After going to the tower, fix the multi-meter on the tower at the position where is easy to see the SDH Rx level when adjusting Connect ends of electric roles to Multimeter to check the receive signal level of this site(choose Volt DC mode) Sau lên đến cột, cột chặt Multimeter vào than cột vị trí dễ dàng để xem mức thu chỉnh Nối đầu cuộn dây điện vào máy đo Multimeter để kiểm tra mức tín hiệu thu trạm (chọn đo volt DC, chiều) Site Check Instruction Ericsson Confidential WORKING INSTRUCTIONS Prepared (also subject responsible if other) 52 (60) No FM South Team For Ref Only Checked Date Rev 2010-06-14 PA1 Reference After this action, we start alightment the antenna Sau thực xong, ta bắt đầu chỉnh tuyến Start horizontal adjustment / Bắt đầu chỉnh theo phương ngang • Loose bolts fixing the horizontal movement Have positions, we need to loose bolts (see pictutes) Vặn lỏng ốc vít chống xoay ngang vị trí (xem hình) Site Check Instruction Ericsson Confidential WORKING INSTRUCTIONS Prepared (also subject responsible if other) No FM South Team For Ref Only Checked Date Rev 2010-06-14 PA1 Reference 53 (60) Site Check Instruction Ericsson Confidential WORKING INSTRUCTIONS Prepared (also subject responsible if other) No FM South Team For Ref Only Checked Date Rev 2010-06-14 PA1 Reference 54 (60) Site Check Instruction Ericsson Confidential WORKING INSTRUCTIONS Prepared (also subject responsible if other) 55 (60) No FM South Team For Ref Only Checked Date Rev 2010-06-14 PA1 Reference • After Loose bolts fixing the horizontal movement, now can adjust in horizontal Sau vặn lỏng ốc vít chống xoay vị trí trên, ta chỉnh tuyến theo phương ngang Site Check Instruction Ericsson Confidential WORKING INSTRUCTIONS Prepared (also subject responsible if other) 56 (60) No FM South Team For Ref Only Checked Date Rev 2010-06-14 PA1 Reference • Adjust the antenna azimuth (left and right and vice versa) until get maximum receive signal level(on Multimeter show the maximum DC voltage) Chỉnh góc phương vị (góc quét ngang, bên trái, bên phải…) tới mức tín hiệu nhận cao (trên Multimeter hiển thị mức điện áp chiều lớn nhất) • After getting the maximum receive signal level Tighten all the bolts for horizontal movement Sau nhận mức tín hiệu tốt nhất, vặn chặt ốc cố định chống quay ngang Start vertical adjustment / Bắt đầu chỉnh theo chiều thẳng đứng • Loose the bolts fixing the vertical movement, and Adjust the antenna vertically (up and down and vice versa) until get maximum receive signal level(the position, see picture) Chỉnh anten theo chiều thẳng đứng (chỉnh lên, xuống) tới nhận tín hiệu thu tốt Site Check Instruction Ericsson Confidential WORKING INSTRUCTIONS Prepared (also subject responsible if other) 57 (60) No FM South Team For Ref Only Checked Date Rev 2010-06-14 PA1 Reference • After getting the maximum receive signal level Tighten the bolts for vertical movement Sau nhận mức tín hiệu thu tốt nhất, vặn chặt ốc chống xoay theo hướng thẳng đứng • Repeat the previous steps in both sites separately in both sites until the calculated RSL is achieved Lặp lại bước phía tuyến truyền dẫn tới đạt mức thu thiết kế Complete the process of SDH antenna adjustment Recheck RSL by MDRS LCT software Refer the document “ETV-OMF-TR-2022- Check TX, RSL and Frequency MDRS” Kết thúc bước chỉnh tuyến SDH Kiểm tra lại mức thu tuyến truyền dẫn phần mềm “LMT Maintenance Terminal MDRS 7.0 564” Tham khảo tài liệu “ETV-OMF-TR-2022Check TX, RSL and Frequency MDRS” Revision history Revision Reference Date 2007-07-23 Name Nguyen Son Tung Draft Revised Approved 2010-06-08 Mac Quoc An Description NVMS-ANO-00xx MIC How to Align SDH hop 1.0 (Bilingual) 1st draft Site Check Instruction Ericsson Confidential WORKING INSTRUCTIONS Prepared (also subject responsible if other) No FM South Team For Ref Only III Checked Date Rev 2010-06-14 PA1 Network Diagram Reference 58 (60) Site Check Instruction Ericsson Confidential WORKING INSTRUCTIONS Prepared (also subject responsible if other) No FM South Team For Ref Only Checked Date Rev 2010-06-14 PA1 Reference 59 (60) Site Check Instruction Ericsson Confidential WORKING INSTRUCTIONS Prepared (also subject responsible if other) No FM South Team For Ref Only IV Checked Date Rev 2010-06-14 PA1 Revision History Revision Draft Date 14-Jun-10 Name FM South Team Revised Approved 14-Jun-10 Vinh Huynh Description 1st draft Reference 60 (60) [...]... Rev 2010-06-14 PA1 Reference Contact to Ericsson Support Team to check status sites after bypass CNODE If get new OMS800, return connection and traffic on OMS that Refer to ETV-OMF-TR-2008 to download files Liên hệ với đội Ericsson phụ trách kiểm tra trạng thái các sites sau khi bypass OMS800 Nếu nhận OMS800 mới thực hiện trả về các kết nối và traffic như trước tham khảo qui trình ETV-OMF-TR-2008 để... trên ODF-NEC kết nối với thiết bị MDRS, mặt sau của ODF-OMS kết nối với thiết bị OMS800, má dưới của ODF-NEC sẽ đấu nhảy qua mặt trước ODF-OMS Ngòai ra còn có thể đấu theo luật 1 2 Bypass OMS800: Case 1: Bypass direct on ODF-OMS: Put Tx optical jumper of Port-1 to Rx optical jumper of Port-2 of MDRS via coupler module and do same for reverse direction (Rx to Tx) b/w Port-1&Port-2 of MDRS Xác định Port... subject responsible if other) No FM South Team For Ref Only Checked Date Rev 2010-06-14 PA1 Reference D Replace Faulty Card of OMS800 Equipment Description: This section describes how to replace faulty cards of OMS800 equipment when it is faulty Hướng dẫn cách thay card của thiết bị OMS800 khi bị hư hỏng Tool requirement: Tools preparation: Small flat head screwdriver (tua vít dẹt loại nhỏ), LAN cable (cáp... của máy tính • Check the communication between PC and equipment: use ping command Kiểm tra kết nối giữa máy tính và thiết bị, sử dụng lệnh ping 15 (60) Site Check Instruction Ericsson Confidential WORKING INSTRUCTIONS Prepared (also subject responsible if other) No FM South Team For Ref Only Checked Date Rev 2010-06-14 PA1 Reference • Run AXX 8920 Craft and type the IP address of NE in to login Chạy phần... WORKING INSTRUCTIONS Prepared (also subject responsible if other) No FM South Team For Ref Only Checked Date Rev 2010-06-14 PA1 Reference E Setup IP OMS800 Instruction Description: This procedure provides to setup IP OMS800 Đây là tài liệu hướng dẫn setup IP OMS800 dùng cho cả OMS860 & 870 Tool requirement: a) RJ45 Cable connection RS232 to USB Cáp RJ45 chuyển đổi qua RS232 sang đầu USB b) Laptop with... the status of using port / Kiểm tra trạng thái của port đang sử dụng 4 - Contact to Ericsson Support Team to check status sites after replacing new card of OMS800 Liên hệ với đội Ericsson phụ trách kiểm tra trạng thái các sites sau thay card của OMS800 - The faulty card must be returned to Ericsson for repair with a repair delivery note Include the Site Check Instruction Ericsson Confidential WORKING... with the VT100 application to the NE as described bellow, and start the application Any VT100 client can be used - Nối cáp từ máy tính tới cổng VT100 trên OMS như hình dưới Open Hyper terminal: Mở phần mềm Hyper Terminal trong Window XP - Click start > Program file > Hyperterminal: Chạy chương trình Hyperterminal trên máy tính - Enter COM port name and select OK - Lựa chọn cổng COM trên Computer management... Confidential WORKING INSTRUCTIONS Prepared (also subject responsible if other) 27 (60) No FM South Team For Ref Only Checked Date Rev 2010-06-14 PA1 Reference F Backup & Restore OMS800 Configuration Description: Guide to backup and restore OMS 8XX configuration with AXX 8920 Craft 6.0 Hướng dẫn backup và restore cấu hình OMS 8XX với phần mềm AXX8920 Craft 6.0 Tool requirement: Laptop with AXX 8920 Craft... window appears, click on the left Sau khi vào cửa số NE Maintenance, nhấn vào nằm bên phía trái cửa số: 1.4 Go to back up and enter file name of backup configuration: - After click (step 1.3) the and buttons on top-left of screen will be available Then click Sau khi nhấn vào (step 1.3) hai biểu tượng và... include IP address of NE and the date/time We can change the filename but recommend that we should use the default name Hộp thoại “Backup Confirmation” sẽ xuất hiện, yêu cầu nhập vào tên file cần lưu lại Mặc định tên file bao gồm địa chỉ IP của thiết bị cùng với ngày, giờ Chúng ta có thể thay đổi tên file nhưng nên dùng tên file mặc đinh : Note: the extension of file name is cdb and it will be automatically

Ngày đăng: 23/11/2016, 14:13

Từ khóa liên quan

Tài liệu cùng người dùng

  • Đang cập nhật ...

Tài liệu liên quan