BS 5467 1997 electric cables — thermosetting insulated, armoured cables for voltages of 6001 0002

44 183 0
BS 5467 1997 electric cables — thermosetting insulated, armoured cables for voltages of 6001 0002

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

Thông tin tài liệu

BS 5467 1997 electric cables — thermosetting insulated, armoured cables for voltages of 6001 0002 BS 5467 1997 electric cables — thermosetting insulated, armoured cables for voltages of 6001 0002 BS 5467 1997 electric cables — thermosetting insulated, armoured cables for voltages of 6001 0002 BS 5467 1997 electric cables — thermosetting insulated, armoured cables for voltages of 6001 0002 BS 5467 1997 electric cables — thermosetting insulated, armoured cables for voltages of 6001 0002

[...]... 0.036 6 0.028 3 — — 0.20 0.18 0.20 0.18 — — — — 800 0.022 1 — 1 000 0.017 6 — Circular sectoral conductor 380 — 0.080 0 480 — 0.063 3 600 — 0.051 5 0.13 0.12 0.13 0.12 — — — — — — — — — — 0.25 0.22 0.20 0.25 0.22 0.20 740 960 1 200 — — — — — — 0.15 0.13 0.12 0.15 0.13 0.12 — — — © BSI 25 February 2004 0.041 0 0.031 3 0.025 0 27 Table H.2 — Maximum resistance of conductor and armour for two-, three-,... 0.61 — — — — — — 1.2 0.86 0.76 0.82 0.76 0.71 0.82 0.74 0.67 240 0.075 4 0.125 0.73 0.63 0.59 0.54 — — 0.68 0.64 0.59 300 400 0.060 1 0.047 0 0.100 — 0.67 0.59 0.58 0.52 0.55 0.50 0.49 0.35 — — — — 0.63 — 0.59 — 0.54 — © BSI 25 February 2004 a The values given are for plain annealed copper conductors For tinned conductors reference should be made to BS 6360 " BS 5467: 1997 28 ! BS 5467: 1997 Table H.3 —. .. 7.9 7.0 6.0 9.5 8.2 7.5 6.7 4.0 — — — — — 8.8 7.7 6.8 4.3 3.7 8.2 6.8 6.2 3.9 3.4 — — — — — — — — — — — — — — — — — — — — 16 25 35 1.15 0.727 0.524 1.91 1.20 0.868 3.7 3.7 2.6 3.5 2.5 2.3 1.9 1.7 1.8 3.1 2.3 2.0 2.2 1.8 1.6 4.0 4.1 2.9 3.8 2.7 2.5 2.0 1.9 1.9 3.4 2.4 2.2 50 70 95 0.387 0.268 0.193 0.641 0.443 0.320 2.3 2.0 1.4 2.0 1.8 1.3 1.3 1.2 1.1 1.8 1.2 1.1 1.1 0.94 — 2.6 2.3 1.6 2.2 1.9 1.4 1.4... percentage elongation at break — Maximum percentage variationa of tensile strength a of elongation at break — Maximum percentage variation a Type 9 8.5 200 30 30 — — — — — — — — 2 12.5 150 25 25 The variation is the difference between the respective values obtained prior to and after heat treatment, expressed as a percentage of the former Table 4 — Single-core 600/1 000 V cables with circular stranded... green 6 © BSI 25 February 2004 BS 5467: 1997 12.2 External marking The external surface of all cables conforming to this British Standard shall be legibly marked with the following elements Element Example of marking a) Electric cable ELECTRIC CABLE b) Voltage designation 600/1 000 V 3 300 V 600/1 000 V AUX c) British Standard number BS 5467 d) Manufacturer’s identification XYZ !e) Number of cores,... A.4.1 Cables installed in and around buildings For current ratings of cables installed in and around buildings reference should be made to BS 7671 A.4.2 Other installations For the current ratings for cables installed in situations other than those covered by A.4.1, reference should be made to the Current Rating Standards for Distribution Cables ERA 69-30 Part V Annex B (informative) Recommendations for. .. test for galvanized steel wire Take at random, from one sample of completed cable, 10 % of the total number of wires Wrap each wire round a cylindrical mandrel for one complete turn The mandrel shall have a diameter of approximately four times the specified nominal wire diameter under test 24 © BSI 25 February 2004 BS 5467: 1997 G.4 Tensile test for aluminium wires Take at random, from one sample of completed... The values of correction factor kt are based on resistance temperature coefficients at 20 °C of 0.004 5 per K for galvanized steel wire and 0.004 0 per K for aluminium wire 26 © BSI 25 February 2004 BS 5467: 1997 Annex H (normative) Resistance of conductor and armour Table H.1, Table H.2, Table H.3, Table H.4 and Table H.5 give maximum values of the conductor resistance and of the resistance of the aluminium... conductor (class 2) 14 © BSI 25 February 2004 BS 5467: 1997 Table 9 — Three-core 600/1 000 V cables with solid aluminium conductors Nominal Thickness Thickness cross-sectional of of area of insulation extruded conductor bedding mm mm2 Nominal steel armour wire diameter Nominal thickness mm mm mm Armour strip Thickness Approximate overall diameter of Nominal Wire -armoured Stripoversheath armoured width Extruded... conductor (class 2) 16 © BSI 25 February 2004 BS 5467: 1997 Table 11 — Four-core 600/1 000 V cables with solid aluminium conductors Nominal cross-sectional area of conductor Thickness Thickness of of insulation extruded bedding mm mm2 Nominal steel armour wire diameter mm Armour strip Thickness Approximate overall diameter of Nominal Nominal oversheath Wire -armoured Stripthickness width armoured Extruded Taped . BRITISH STANDARD BS 5467:1997 Incorporating Amendment No. 1 Electric cables — Thermosetting insulated, armoured cables for voltages of 600/1 000 V and 1 900/3 300 V ICS. 9 Annex A (informative) Recommendations for the selection and operation of cables 21 Annex B (informative) Recommendations for the installation of cables 22 Annex C (informative) Information to. Electric cables. BS 5099:1992, Specification for spark testing of electric cables. BS 6360:1991, Specification for conductors in insulated cables and cords. BS 7655-1.2:1993, Specification for insulating

Ngày đăng: 28/09/2014, 23:27

Từ khóa liên quan

Tài liệu cùng người dùng

  • Đang cập nhật ...

Tài liệu liên quan