Báo cáo khoa học: "Simultaneous integrated boost radiotherapy for bilateral breast: a treatment planning and dosimetric comparison for volumetric modulated arc and fixed field intensity modulated therapy" ppsx

12 312 0
Báo cáo khoa học: "Simultaneous integrated boost radiotherapy for bilateral breast: a treatment planning and dosimetric comparison for volumetric modulated arc and fixed field intensity modulated therapy" ppsx

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

Thông tin tài liệu

Radiation Oncology BioMed Central Open Access Methodology Simultaneous integrated boost radiotherapy for bilateral breast: a treatment planning and dosimetric comparison for volumetric modulated arc and fixed field intensity modulated therapy Giorgia Nicolini, Alessandro Clivio, Antonella Fogliata, Eugenio Vanetti and Luca Cozzi* Address: Oncology Institute of Southern Switzerland, Medical Physics Unit, Bellinzona, Switzerland Email: Giorgia Nicolini - giorgia.nicolini@eoc.ch; Alessandro Clivio - alessandro.clivio@eoc.ch; Antonella Fogliata - afc@iosi.ch; Eugenio Vanetti - eugenio.vanetti@eoc.ch; Luca Cozzi* - lucozzi@iosi.ch * Corresponding author Published: 24 July 2009 Radiation Oncology 2009, 4:27 doi:10.1186/1748-717X-4-27 Received: 26 May 2009 Accepted: 24 July 2009 This article is available from: http://www.ro-journal.com/content/4/1/27 © 2009 Nicolini et al; licensee BioMed Central Ltd This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited Abstract Purpose: A study was performed comparing dosimetric characteristics of volumetric modulated arcs (RapidArc, RA) and fixed field intensity modulated therapy (IMRT) on patients with bilateral breast carcinoma Materials and methods: Plans for IMRT and RA, were optimised for 10 patients prescribing 50 Gy to the breast (PTVII, 2.0 Gy/fraction) and 60 Gy to the tumour bed (PTVI, 2.4 Gy/fraction) Objectives were: for PTVs V90%>95%, Dmax

Ngày đăng: 09/08/2014, 10:20

Từ khóa liên quan

Mục lục

  • Abstract

    • Purpose

    • Materials and methods

    • Results

    • Conclusion

    • Background

    • Methods and patients

      • Patient selection and planning objectives

      • Planning techniques

        • IMRT

        • RapidArc (RA)

        • Pre-treatment Quality Assurance dosimetric measurements

        • Evaluation tools

        • Results

          • Target coverage and dose homogeneity

          • Organs at risk

          • Healthy tissue

          • Delivery parameters

          • Pre-treatment dosimetric measurements

          • Discussion and conclusion

          • Competing interests

          • Authors' contributions

          • References

Tài liệu cùng người dùng

Tài liệu liên quan