HLP-SV Series User''''s Manual pps

90 1.1K 3
HLP-SV Series User''''s Manual pps

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

Thông tin tài liệu

Inverter HLP-SV Series User’s Manual Inverter Zhejiang HOLIP Electronic Technology co.,Ltd ADD: Section C, 7/F, Wuchan Building, NO.445,Kaixuan Road, Hangzhou TEL: 0571-86772676 FAX: 0571-86772912 Http: //www.holip.com Inverter Ⅰ Introduction .4 Checks upon Delivery Nameplate Description of HLP –SV Series Inverter Ⅱ Safety Precautions Before the Power-up During the Power-up During the Operation Ⅲ Standards and Specifications .10 Particular Specifications 10 General Specifications 11 Ⅳ Storage and Installation 13 Storage 13 Installation Site and Environment 13 Installation and Direction 13 Ⅴ Wiring .14 Main Circuit Wiring Schematic Diagram 14 Description of Terminal Block 15 Basic Connection Diagram 17 Switches 17 Precautions on Wiring 18 Ⅵ Instruction of the LCP Digital Operator 20 Description of the LCP Digital Operator 20 Programming with LCP 20 VII Parameter Overview 23 VIII Parameter Descriptions .32 Ⅹ Maintenance, Fault Information and Troubleshooting 79 Precautions about Inspection and Maintenance 80 Periodical Inspection and Maintenance items 80 Fault Indication and Troubleshooting 80 IX Appendices 82 Appendix 1: Mounting Dimensions of HOLIP SV inverters 82 Appendix 2: Mounting Dimensions of LCP Digital operator 83 Appendix 3:User’s feedback 84 Inverter Ⅰ Introduction Thank you for purchasing and using the general-purpose inverter of HLP –SV series of multi-functions and high performance Please read carefully the operation manual before putting the inverter to use so as to correctly install and operate the inverter, give full play to its functions and ensure the safety Please keep the operation manual handy for future reference, maintenance, inspection and repair Due to the inverter of a kind of electrical and electronic product it must be installed, tested and adjusted with parameters by specialized engineering persons of motors Caution and other symbols in the manual remind you of the safety ~Danger and prevention cautions during the handling, installation, running and inspection Please follow these The marks of instructions to make sure the safe use of the inverter In case of any doubt please contact our local agent for consultation Our professional persons are willing and ready to serve you The manual is subject to change without notice Danger ! l l l l l l l indicates wrong use may kill or injure people Caution indicates wrong use may damage the inverter or mechanical system ~ Danger Be sure to turn off the input power supply before wiring Do not touch any internal electrical circuit or component when the charging lamp is still on after the AC power supply is disconnected, which means the inverter still has high voltage inside and it is very dangerous Do not check components and signals on the circuit boards during the operation Do not dissemble or modify any internal connecting cord, wiring or component of the inverter by yourself Be sure to make correct ground connection of the earth terminal of the inverter Never remodel it or exchange control boards and components by yourself It may expose you to an electrical shock or explosion, etc ! Caution Motor overload protection is included in the default settings Parameter 1-90 Motor thermal protection is set to value ETR trip l l l l l Do not make any voltage-withstanding test with any component inside the inverter These semi-conductor parts are subject to the damage of high voltage Never connect the AC main circuit power supply to the output terminals U.V W of the inverter The main electric circuit boards of CMOS and IC of the inverter are subject to the effect and damage of static electricity Don’t touch the main circuit boards Installation, testing and maintenance must be performed by qualified professional personnel The inverter should be discarded as industrial waste It is forbidden to burn it Inverter Checks upon Delivery The inverter has been strictly and well packed before ex-work In consideration of various factors during the transportation special attention should be paid to the following points before the assembly and installation If there is anything abnormal please notify the dealer or the relevant people of our company l l l l l l l l Check if the inverter has got any damage or deformation during the transportation and handling Check if there is one piece of HLP-SV series inverter and one copy of the instruction manual available when unpacking it Check the information on the nameplate to see if the specifications meet your order (Operating voltage and KVA value) Check if there is something wrong with the inner parts, wiring and circuit board Check if each terminal is tightly locked and if there is any foreign article inside the inverter Check if the operator buttons are all right Check if the optional components you ordered are contained Check if there is a certificate of qualification and a warranty card Nameplate Description of HLP –SV Series Inverter HLP-SV T/C:HLPSV0D7523A P/N: 3002102 S/N:010000-466 0.75KW 1HP IN:3×200-240V 50/60HZ 11.6A OUT:3×0-Vin 0-400HZ 4.2A CHASSIS: IP20 Temp:40℃/104oF c/n: O/N:WWW00022165 MADE IN P.R.C CAUTION SEE MANUAL WARNING STORED CHARGE DO NOT TOUCH UNTIL MIN.AFTER DISCONNECTION RISK OF ELECTRIC SHOCK-DUAL SUPPLY DISCONNECT MAINS AND LOADSHARING BEFORE SERVICE Inverter ` Model:HLP SV 0D75 23 A Software Version: A Voltage Rating:21: 1-Phase AC 220V 23: 3-Phase AC 220V 43: 3-Phase AC 380V Inverter Capacity:0 D 75 means 0.75KW Serial No:SV means SV series Trade Mark Inverter • Safety Precautions Before the Power-up l ! Caution Check to be sure that the voltage of the main circuit AC power supply matches the input voltage of the inverter l The symbol, E , represents ground terminals Be sure to make correct ground connection of the earth terminals of the motor and the inverter for safety l No contactor should be installed between the power supply and the inverter to be used for starting or stopping of the inverter Otherwise it will affect the service life of the inverter Danger l L1 L2 L3 terminals are power input terminals, never mixed with U.V.W terminals Be sure that the wiring of the main circuit is correct Otherwise it will cause damages of the inverter when the power is applied to it l The terminal of E must be grounded separately and never connected to line zero Otherwise it will easily cause the protection or errors of the inverter l Caution ! Do not carry the front cover of the inverter directly when handling It should be handled with the base to prevent the fall-off of the front cover and avoid the dropping of the inverter, which may possibly cause the injuries to people and the damages to the inverter l Mount the inverter on a metal or other noncombustible material to avoid the risk of fire l Install the inverter in a safe location, avoiding high temperature, direct sunlight, humid air or water l Keep the inverter from the reach of children or persons not concerned l The inverter can only be used at the places accredited by our company Any unauthorized working environment may have the risks of fire, gas explosion, electric shock and other incidents l Install a heat sink or other cooling device when installing more than one inverter in the same enclosure so that the temperature inside the enclosure be kept below 40℃ to avoid overheat or the risk of fire l Be sure to turn off the power supply before dissembling or assembling the operation keypanel and fixing the front cover to avoid bad contact causing faults or non-display of the operator l Do not install the inverter in a space with explosive gas to avoid the risk of explosion l If the inverter is used at or above 1000m above seal level, the cooling efficiency will be worse, so please run it by de-rating l Do not install any contactor and other components of capacitor or varistor on the output side of the inverter Otherwise it will cause malfunctions and damages of components of the inverter l Do not install any switch component like air circuit breaker or contactor at the output of the inverter If any of such components must be installed because of the requirements of process and others, it must be ensured that the inverter has no output when the switch acts In addition, Inverter it is forbidden to install any capacitor for improvement of power factor or any varistor against thunder at the output Otherwise it will cause malfunctions, tripping protection and damages of components of the inverter Please remove them as shown in the below diagram l It will affect the service life of the inverter if a contact is connected to the front end of input of the inverter to control its starts and stops Generally it is required to control it through Control terminals Special attention should be paid to its use in the case of frequent starts and stops l Please use an independent power supply for the inverter Do avoid using the common power supply with an electrical welder and other equipment with strong disturbance Otherwise it will cause the protection or even damage of the inverter X KM U Inverter V M W X During the Power-up Danger l Do not plug the connectors of the inverter during the power up to avoid any surge into the main l control board due to plugging, which might cause the damage of the inverter Always have the protective cover in place before the power up to avoid electrical shock injury During the Operation Danger l Never connect or disconnect the motor set while the inverter is in running Otherwise it will cause over-current trip and even burn up the main circuit of the inverter l Never remove the front cover of the inverter while the inverter is powered up to avoid any injury of electric shock l Do not come close to the machine when the fault restart function is used to avoid anything unexpected The motor may automatically restart after its stop l The function of STOP Switch is only valid after setting, which is different with the use of emergent stop switch Please pay attention to it when using it Inverter ! l Caution Touching the electrical parts may be fatal - even after the equipment has been disconnected from mains Also make sure that other voltage inputs have been disconnected, (linkage of DC intermediate circuit) l Be aware that there may be high voltage on the DC link even when the LEDs are turned off l Before touching any potentially live parts of the VLT Micro, wait at least as follows: 200 - 240 V, 0.4 – 1.5 kW: wait at least minutes 380 - 480 V,0.75 – 2.2 kW: wait at least minutes Shorter time is allowed only if indicated on the nameplate for the specific unit Inverter • Standards and Specifications Particular Specifications Product Order Model 30002101 30002102 30002103 ** ** 30002301 30002302 30002303 ** ** 30004302 30004303 HLPSV00D421A HLPSV0D7521A HLPSV01D521A HLPSV02D221A HLPSV03D721A HLPSV00D423A HLPSV0D7523A HLPSV01D523A HLPSV02D223A HLPSV03D723A HLPSV0D7543A HLPSV01D543A 30004304 HLPSV02D243A ** ** HLPSV03D743A HLPSV05D543A ** HLPSV07D543A Input Voltage Power (KW) Inverter Output Suitable Capacity Current Motor (KVA) (A) (KW) 1×200-240V 50/60Hz 1×200-240V 50/60Hz 1×200-240V 50/60Hz 1×200-240V 50/60Hz 1×200-240V 50/60Hz 3×200-240V 50/60Hz 3×200-240V 50/60Hz 3×200-240V 50/60Hz 3×200-240V 50/60Hz 3×200-240V 50/60Hz 3×380-480V 50/60Hz 0.4 0.75 1.5 2.2 3.7 0.4 0.75 1.5 2.2 3.7 0.75 1.0 2.0 2.8 ** ** 1.0 2.0 2.8 ** ** 2.2 2.5 4.2 6.8 ** ** 2.5 4.2 6.8 ** ** 2.2 0.4 0.75 1.5 2.2 3.7 0.4 0.75 1.5 2.2 3.7 0.75 3×380-480V 50/60Hz 1.5 3.2 3.7 1.5 3×380-480V 50/60Hz 2.2 4.0 5.3 2.2 3×380-480V 50/60Hz 3.7 5.5 ** ** 3.7 3×380-480V 50/60Hz ** ** 3×380-480V 50/60Hz 7.5 ** ** **:These dimensions will be announced at a later point 10 5.5 7.5 Inverter Default setting Range l Default setting Motor Current Range [0.00 - 1856.00 A] Function: View motor phase current 16-15 Frequency [%] Range [-100.00 - 100.00%] Function: View a two-byte word reporting actual motor frequency as a percentage of par X-XX 16-18 Default setting Motor Thermal Range l 0.00 [0.0 - 400.0 Hz] Function: View output frequency in Hz 16-14 l 0.00A Default setting Frequency Range l 0.0HZ [0.0 - 999.9 V] Function: View motor phase voltage 16-13 l 0.0 Default setting 16-12 Motor Voltage 0% [0 - 100%] Function: View calculated thermal motor load as percentage of estimated thermal motor load 16-3* Drive Status Parameters for reporting the status of the frequency converter 16-30 Range l [0 - 10000 V] Default setting 0.00A Default setting Inv Nom Current Range 0.00A [0.01 - 10000.00 A] Function: View continuous nominal inverter current 16-37 Inv Max Current Range l Function: View DC-link voltage 16-36 l Default setting DC Link Voltage [0.1 - 10000.00 A] Function: View intermittent maximum inverter current (150%) 76 Inverter 16-5* Ref & Feedb Parameters for reporting the reference and feedback input 16-50 Range l Default setting 0.0% [-200.0 - 200.0%] Pulse Reference Range [-200.0 - 200.0%] Function: View actual pulse input converted to a reference in percent 16-52 Default setting 0.000 Default setting Default setting Default setting Feedback [Unit] Range l 0.0% Function: View sum of all external references in percent 16-51 l Default setting External Reference 0.00 [-4999.000 -4999.000] Function: View analog or pulse feedback in Hz 16-6* Inputs and Outputs Parameters for reporting the digital and analog IO ports 16-60 Digital Input 18,19,27,33 Range l Function: View signal states from active digital inputs 16-61 Digital Input 29 Range l [0 - 1] Function: View signal state on digital input 29 16-62 Analog Input 53 (volt) Range l [0 - 1111] [0.00 - 10.00 V] Function: View input voltage on analog input terminal 77 Inverter Default setting Range l Analog Input 60 Range 0Hz Default setting [20 - 5000 Hz] Function: View input frequency on pulse input terminal 16-71 Relay Output [bin] Range [0 - 1] Function: View relay setting 16-72 Default setting Default setting Counter A Range [-2147483648 -2147483647] Function: View present value of Counter A 16-73 Counter B Range l Default setting [0.00 - 20.00 mA] Pulse Input Range l 0.00 Function: View output current on analog output 42 16-68 l Default setting Analog Output 42 [mA] Range l [0.00 - 20.00 mA] Function: View actual value at input 60 either as reference or protection value 16-65 l 0.00 [0.00 - 20.00 mA] Function: View input current on analog input terminal 16-64 l 0.00 Default setting 16-63 Analog Input 53 (current) [-2147483648 -2147483647] Function: View present value of Counter B 16-8* FC Port Parameter for viewing references from FC Port 16-86 Range l Default setting FC Port REF [-200 - 200] Function: View currently received reference from FC Port 78 Inverter 16-9* Diagnosis Read-Out Parameters displaying alarm, warning and extended status words 16-90 Range l [0 - 0x7FFFFFFFUL] Default setting Warning Word Range [0 - 0x7FFFFFFFUL] Function: View warning word sent via serial communication port in hex code 16-94 Default setting Ext Status Word Range l Function: Via alarm word sent via serial communication port in hex code 16-92 l Default setting Alarm Word [0 - 0xFFFFFFFUL] Function: View extended warning word sent via serial communication port in hex code • Maintenance, Fault Information and Troubleshooting Periodical maintenances and inspections will keep your inverter in its normal state for long time 79 Inverter Precautions about Inspection and Maintenance l Be sure to turn off the power supply to the inverter(L1.L2.L3)first before the inspection and maintenance l After confirming the main circuit power supply has been turned off and the display has disappeared, wait until the internal indicator lamp for high voltage goes out before performing the inspection and maintenance l During the inspection, not pull out or wrongly distribute the internal power supply, wires and cables Otherwise it will cause malfunction or damage to the inverter l Do not leave any screw or other part inside the inverter during the installation, or it will result in the short circuit of circuit board l Keep the inverter clean, free from dust, oil mist and moisture after the installation Periodical Inspection and Maintenance items l Check whether the power supply voltage conforms to the rated voltage of the inverter (Pay special attention to that whether there is any damage on the power supply wires and the motor.) l Check whether the wiring terminals and the connectors are tight l (Check whether the power supply wires and terminal connection wires have any broken strand) Check whether there is dust, iron filings or corrosive fluid in the inverter l Measuring the insulation impedance of the inverter is forbidden l Examine the output voltage, output current and output frequency of the inverter (The measuring results should not have too big difference.) l Check whether the ambient temperature of the inverter is between -5℃ and 40℃ and whether the l installation environment has good ventilation Check whether the humidity is kept between 5% and 90% (without condensation) l Check whether the motor makes unusual noises or abnormal vibration in running l (The inverter should not be installed in a place with high vibration.) Please make periodical cleaning of vent holes Fault Indication and Troubleshooting The inverter of HLP-SV series is relatively perfective with the protection functions of overload, inter-phase short circuit, earth short circuit, under-voltage, overheating and over-current, etc When a protection function happens with the inverter please check the reasons of faults according to the information listed in the table below The inverter can be restarted after the disposal If the fault cannot be disposed please contact the local distributor 80 Inverter Fault Display Fault Contents & Description W/A Live zero error W/A Mains phase loss W/A DC over voltage W/A DC under voltage W/A Inverter overloaded Disposal methods Signal on terminal 53 or 60 is less than 50% of value set in par 6-10, 6-12 and 6-22 Missing phase on supply side, or too high voltage imbalance Check supply voltage Intermediate circuit voltage exceeds limit Intermediate circuit voltage drops below “voltage warning low” limit More than 100% overload for too long W/A 10 Motor ETR over temperature Motor is too hot due to more than 100% overload for too long W/A 12 Torque limit Torque exceeds value set in either par 4-16 or 4-17 W/A 13 Over Current Inverter peak current limit is exceeded W/A 14 Earth fault Discharge from output phases to ground A 16 Short Circuit W/A 17 Control word timeout Short-circuit in motor or on motor terminals No communication to frequency converter W 25 Brake resistor short-circuited Brake resistor is short-circuited, thus brake function is disconnected W /A 27 Brake chopper short-circuited Brake transistor is short-circuited, thus brake function is disconnected W/A 28 Brake check Brake resistor is not connected/working W/A 29 Power board over temp Heat-sink cut-out temperature has been reached W/A 30 Motor phase U missing Motor phase U is missing Check the phase W/A 31 Motor phase V missing Motor phase V is missing Check the phase W/A 32 Motor phase W missing Motor phaseW is missing Check the phase A 38 Internal fault W/A 47 24 V supply low A 52 AMT low Inom W/A 58 AMT internal fault W 59 Current limit A 80 Drive Initialised to Default Value Note: A=Alarm W=Warning Contact local HOLIP supplier External 24 V DC back-up power supply may be overloaded Motor current is too low Check settings Contact local HOLIP supplier Contact local HOLIP supplier All parameter settings are initialized to default settings 81 Inverter IX Appendices Appendix 1: Mounting Dimensions of HOLIP SV inverters 1) Mechanical drawing Appearance and Installation Dimensions B A F C HLPSV00D421A HLPSV0D7521A HLPSV01D521A HLPSV02D221A** HLPSV03D721A** HLPSV00D423A HLPSV0D7523A HLPSV01D523A HLPSV02D223A** HLPSV03D723A** HLPSV0D7543A HLPSV01D543A HLPSV02D243A HLPSV03D743A** HLPSV05D543A** HLPSV07D543A** D Inverter Model G E 4.4 单位:mm Unit: F G 单位:mm 2):External Dimensions Table (Unit: mm) Inverter Model HLPSV00D421A A B C D E F G Φ4.5 Φ4.5 55 70 141 150 148 HLPSV02D221A** 60 ** 75 ** 168 ** 180 ** 168 ** ** ** HLPSV03D721A** ** ** ** ** ** ** ** 55 70 141 150 148 HLPSV02D223A** 60 ** 75 ** 168 ** 180 ** 168 ** HLPSV03D73A** ** ** ** ** ** Φ4.5 Φ4.5 HLPSV0D7543A 55 70 141 150 148 60 75 168 180 168 HLPSV03D743A** ** ** ** ** ** ** ** HLPSV05D543A** ** ** ** ** ** ** ** HLPSV07D543A** ** ** ** ** ** ** ** HLPSV0D7521A HLPSV01D521A HLPSV00D423A HLPSV0D7523A HLPSV01D523A HLPSV01D543A HLPSV02D243A 82 Inverter **:These dimensions will be announced at a later point Appendix 2: Mounting Dimensions of LCP Digital operator Inverter Model Appearance and Installation Dimensions HOLIP-SV LCP operator 单位:mm Unit: 83 Inverter Appendix 3:User’s feedback Item Function Code Fuction Description Default setting Oper State at Power-up (Hand) 0-10 Active Set-up 0-11 Edit Set-up 0-12 Link Setups 20 0-40 [Hand on] Key on LCP 0-41 [Off / Reset] Key on LCP 0-42 [Auto on] Key on LCP 0-50 LCP Copy 0-51 Set-up Copy 0-60 (Main) Menu Password 1-00 Configuration Mode 1-01 Motor Control Principle 1-03 Torque Characteristics 1-05 Local Mode Configuration 1-20 Motor Power [kW] [HP] ** 1-22 Motor Voltage ** 1-23 Motor Frequency ** 1-24 Motor Current ** 1-25 Load / Motor Regional Settings 0-04 Operation / Display 0-03 Motor Nominal Speed ** 1-29 Automatic Motor Tuning (AMT) 1-30 Stator Resistance (Rs) ** 1-33 Stator Leakage Reactance (X1) ** 1-35 Main Reactance (Xh) ** 1-50 Motor Magnetisation at Speed 100% 1-52 Min Speed Norm Magnet [Hz] 0.0H z 1-55 U/f Characteristic - U 0V 1-56 U/f Characteristic - F 0H z 1-60 Low Speed Load Compensation 100% 1-61 High Speed Load Compensation 100% 1-62 Slip Compensation 100% 1-63 Slip Compensation Time Constant 0.10s 1-71 Start Delay 0.0S 84 User’s Par Inverter Start Function 1-73 Flying Start Function Code 1-80 Function at Stop 1-82 Min Speed for Funct at Stop [Hz] 1-90 Motor Thermal Protection 1-93 Thermistor Resource 2-00 DC Hold Current 50% 2-01 DC Brake Current 50% 2-02 DC Braking Time 10.0S 2-04 DC Brake Cut In Speed 0.0Hz 2-10 Brake Function 2-11 Brake Resistor (ohm) 110Ω 2-16 AC Brake, Max current 100% 2-17 Over-voltage Control 2-20 Release Brake Current 0.00A 2-22 Activate Brake Speed [Hz] 0.0HZ 3-00 Reference Range 3-02 Minimum Reference 0.000 3-03 Maximum Reference 50.000 3-10 Preset Reference 0.00% 3-11 Jog Speed [Hz] 5.0Hz 3-12 Catch up/slow Down Value 0.00% 3-14 Preset Relative Reference 0.00% 3-15 Reference Resource 1 3-16 Reference Resource 2 3-17 Reference Resource 21 3-18 Relative Scaling Ref Resource 3-40 Ramp Type 3-41 Ramp Ramp up Time 3.000S 3-42 Ramp Ramp Down Time 3.000S 3-50 Ramp Type 3-51 Ramp Ramp up Time 3.000S 3-52 Ramp Ramp down Time 3.000S 3-80 Jog Ramp Time 3.000S Reference / Ramps Brakes Item Load / Motor 1-72 Fuction Description Default setting 0.0Hz 0 0 85 Inverter 3-81 Item Function Code Quick Stop Ramp Time 3.000S Fuction Description Default setting 0.0Hz 4-14 Motor Speed High Limit [Hz] 65.0Hz 4-16 Torque Limit Motor Mode 100% 4-17 Torque Limit Generator Mode 100% 4-50 Warning Current Low 0.00A 4-51 Warning Current High 26.00A Missing Motor Phase Function 4-61 Bypass Speed From [Hz] 0.0Hz 4-63 Bypass Speed To [Hz] 0.0Hz 5-10 Terminal 18 Digital Input 5-11 Terminal 19 Digital Input 10 5-12 Terminal 27 Digital Input 5-13 Terminal 29 Digital Input 14 5-15 Terminal 33 Digital Input 5-40 Function Relay 5-55 Terminal 33 Low Frequency 20 5-56 Terminal 33 High Frequency 5000 5-57 Term 33 Low Ref./Feedb Value 0.000 5-58 Term 33 High Ref./Feedb Value 50.000 6-00 Live Zero Timeout Time 6-01 Live Zero TimeoutFunction 6-10 Terminal 53 Low Voltage 0.07V 6-11 Digital In / out Motor Speed Low Limit [Hz] 4-58 Analog In / Out Motor Speed Direction 4-12 Limits / Warnings 4-10 Terminal 53 High Voltage 10.00V 6-12 Terminal 53 Low Current 0.14 6-13 Terminal 53 High Current 20.00 6-14 Term 53 Low Ref./Feedb Value 0.000 6-15 Term 53 High Ref./Feedb Value 50.000 6-16 Terminal 53 Filter Time Constant 0.01 6-19 Terminal 53 mode 6-22 Terminal 60 Low Current 0.14 6-23 Terminal 60 High Current 20.00 10S 0 86 Inverter Term 60 High Ref./Feedb Value 50.000 Terminal 60 Filter Time Constant 0.010 6-81 LCP potm Low Ref./Feedb Value 0.000 6-82 LCP potm High Ref./Feedb Value 50.000 6-90 Terminal 42 Mode 6-91 Terminal 42 Analog Output 6-92 Terminal 42 Digital Output 6-93 Terminal 42 Output Min Scale 0.00% 6-94 Terminal 42 Output Max Scale 100.00% 7-20 Process CL Feedback Resource 7-30 Process PI Normal/ Inverse Ctrl 7-31 Process PI Anti Windup 7-32 Process PI Start Speed 0.0 7-33 Process PI Proportional Gain 0.01 7-34 Process PI Integral Time 7-38 Process PI Feed Forward Factor 0% 7-39 On Reference Bandwidth 5% 8-01 Control Site 8-02 Control Word Source 8-03 Control Word Timeout Time 8-04 Control Word Timeout Function 8-06 Reset Control Word Timeout 8-30 Protocol 8-31 Proess PI Controlers 0.000 6-26 Communication Term 60 Low Ref./Feedb Value 6-25 Analog In / Out 6-24 Address 8-32 FC Port Baud Rate 8-33 FC Port Parity 8-35 Minimum Response Delay 0.010S 8-36 Max Response Delay 5.000S 8-50 Coasting Select 8-51 Quick Stop Select 8-52 DC Brake Select 8-53 Start Select 8-54 Reversing Select 8-55 Set-up Select 8-56 Preset Reference Select 87 9999.00 1.0S Inverter Switching Frequency Overmodulation 14-12 Function at mains imbalance 14-20 Reset Mode 14-21 Automatic Restart Time 14-22 Operation Mode 14-41 AEO Minimum Magnetisation 15-00 Operating Time 15-01 Running Hours 15-02 kWh Counter 15-03 Power Ups 15-04 Over Temps 15-05 Over Volts 15-06 Reset kWh Counter 15-07 Reset Running Hours Counter 15-30 Fault Log: Error Code 15-40 FC Type ** 15-41 Power Section ** 15-42 Voltage ** 15-43 Software Version ** 15-46 Frequency Converter Order No ** 15-48 LCP Id No ** 15-51 Frequency Converter Serial No ** 16-00 Control Word 16-01 Drive Information 14-03 Data Readouts Bus feedback 14-01 Special Function 8-94 Reference [Unit] 16-02 Reference % 0.0 16-03 Status Word 16-05 Main Actual Value [%] 0.00 16-10 Power [kW] 0KW 16-11 Power [hp] 0HP 16-12 Motor Voltage 0.0 16-13 Frequency 10S 66% 0.000 0.0Hz 88 Inverter Motor Current 0.00A 16-15 Frequency [%] 0.00% 16-18 Motor Thermal 0% 16-30 DC Link Voltage 16-36 Inv Nom Current 0.00A 16-37 Inv Max Current 0.00A 16-50 External Reference 0.0% 16-51 Pulse Reference 0.0% 16-52 Feedback [Unit] 0.000 16-60 Digital Input 18,19,27,33 16-61 Digital Input 29 16-62 Data Readouts 16-14 Analog Input 53 (volt) 0.00 16-63 Analog Input 53 (current) 0.00 16-64 Analog Input 60 0.00 16-65 Analog Output 42 [mA] 0.00 16-68 Pulse Input 20Hz 16-71 Relay Output [bin] 16-72 Counter A 16-73 Counter B 16-86 FC Port REF 16-90 Alarm Word 16-92 Warning Word 16-94 Ext Status Word 89 Inverter 90 ... during the transportation and handling Check if there is one piece of HLP-SV series inverter and one copy of the instruction manual available when unpacking it Check the information on the nameplate... purchasing and using the general-purpose inverter of HLP –SV series of multi-functions and high performance Please read carefully the operation manual before putting the inverter to use so as to correctly... is a certificate of qualification and a warranty card Nameplate Description of HLP –SV Series Inverter HLP-SV T/C:HLPSV0D7523A P/N: 3002102 S/N:010000-466 0.75KW 1HP IN:3×200-240V 50/60HZ 11.6A

Ngày đăng: 01/07/2014, 21:20

Từ khóa liên quan

Tài liệu cùng người dùng

Tài liệu liên quan