Water-Quality Data from Semipermeable-Membrane Devices and Polar Organic Chemical Integrative Samplers Deployed in the McKenzie River Basin, Oregon pptx

14 477 0
Water-Quality Data from Semipermeable-Membrane Devices and Polar Organic Chemical Integrative Samplers Deployed in the McKenzie River Basin, Oregon pptx

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

Thông tin tài liệu

Prepared in cooperation with the Eugene Water and Electric Board Water-Quality Data from Semipermeable-Membrane Devices and Polar Organic Chemical Integrative Samplers Deployed in the McKenzie River Basin, Oregon U.S. Department of the Interior U.S. Geological Survey Data Series 692 Water-Quality Data from Semipermeable-Membrane Devices and Polar Organic Chemical Integrative Samplers Deployed in the McKenzie River Basin, Oregon By Kathleen A. McCarthy and David A. Alvarez Prepared in cooperation with the Eugene Water and Electric Board Data Series 692 U.S. Department of the Interior U.S. Geological Survey U.S. Department of the Interior KEN SALAZAR, Secretary U.S. Geological Survey Marcia K. McNutt, Director U.S. Geological Survey, Reston, Virginia: 2012 For more information on the USGS—the Federal source for science about the Earth, its natural and living resources, natural hazards, and the environment, visit http://www.usgs.gov or call 1–888–ASK–USGS. For an overview of USGS information products, including maps, imagery, and publications, visit http://www.usgs.gov/pubprod To order this and other USGS information products, visit http://store.usgs.gov Any use of trade, product, or firm names is for descriptive purposes only and does not imply endorsement by the U.S. Government. Although this report is in the public domain, permission must be secured from the individual copyright owners to reproduce any copyrighted materials contained within this report. Suggested citation: McCarthy, K.A., and Alvarez, D.A., 2012, Water-quality data from semipermeable-membrane devices and polar organic chemical integrative samplers deployed in the McKenzie River basin, Oregon: U.S. Geological Survey Data Series 692, 6 p. iii Contents Abstract 1 Introduction 1 Environmental Setting and Data‑Collection Sites 1 Sample Collection, Laboratory Methods, and Quality Assurance 1 SPMD and POCIS Data 1 References Cited 3 Appendix 1. Data from Passive Samplers Deployed in the Mckenzie River Basin, Oregon, During 2007. 5 Appendix 2. Data from Passive Samplers Deployed in the Mckenzie River Basin, Oregon, During 2010. 5 Figures Figure 1. Map showing study area location and data‑collection sites, McKenzie River basin, Oregon …………………………………………………………………… 2 iv Conversion Factors, Datum, and Acronyms Conversion Factors Inch/Pound to SI Multiply By To obtain inch (in.) 2.54 centimeter (cm) foot (ft) 0.3048 meter (m) mile (mi) 1.609 kilometer (km) square mile (mi 2 ) 2.590 square kilometer (km 2 ) gallon (gal) 3.785 liter (L) gallon (gal) 0.003785 cubic meter (m 3 ) SI to Inch/Pound Multiply By To obtain centimeter (cm) 0.3937 inch (in.) meter (m) 3.281 foot (ft) kilometer (km) 0.6214 mile (mi) square kilometer (km 2 ) 0.3861 square mile (mi 2 ) liter (L) 0.2642 gallon (gal) cubic meter (m 3 ) 264.2 gallon (gal) nanogram (ng) 35.27 × 106 ounce, avoirdupois (oz) picogram (pg) 35.27 × 109 ounce, avoirdupois (oz) Datum Horizontal coordinate information is referenced to the North American Datum of 1983 (NAD 83). Acronyms CERC Columbia Environmental Research Center DEET N,N‑diethyltoluamide DEHP Diethylhexylphthalate EEQ Estradiol equivalent EST Environmental Sampling Technologies, Inc. EWEB Eugene Water and Electric Board HCB Hexachlorobenzene MDLs Method detection limits MQLs Method quantification limits NQ Not quantified PAH Polycyclic aromatic hydrocarbon PBDE Polybrominated diphenyl ether PCA Pentachloroanisole PCB Polychlorinated biphenyl POCIS Polar organic chemical integrative sampler PRC Performance reference compound QC Quality control RSD Relative standard deviation SEC Size exclusion chromatography SPMD Semipermeable membrane device USGS U.S. Geological Survey Water-Quality Data from Semipermeable-Membrane Devices and Polar Organic Chemical Integrative Samplers Deployed in the McKenzie River Basin, Oregon By Kathleen A. McCarthy and David A. Alvarez Abstract Two types of passive samplers—the semipermeable membrane device (SPMD) and the polar organic chemical integrative sampler (POCIS)—are being used to collect data from the McKenzie River, Oregon. The McKenzie River is the source of drinking water for the City of Eugene, Oregon, and passive-sampler data are part of an ongoing monitoring effort designed to help understand and protect the drinking water source. Data from the passive samplers are reported here. This data report is dynamic and will be appended with additional data as they become available. Introduction The McKenzie River is the source of drinking water for approximately 200,000 people in the Eugene area of Oregon (g. 1). To protect this source, the Eugene Water and Electric Board (EWEB) has implemented a source protection program (Eugene Water and Electric Board, 2000) that includes monitoring water in the McKenzie River basin for the presence of anthropogenic organic compounds. Among the organic compounds of interest to EWEB are many that may have human-health consequences at concentrations that are orders of magnitude less than the detection limits associated with conventional water-sampling techniques. In addition, many compounds of interest may be present only during episodic events. Two types of passive samplers—the semipermeable membrane device (SPMD) and the polar organic chemical integrative sampler (POCIS)—are being used to address these particular challenges. Both the SPMD (Huckins and others, 2006) and POCIS (Alvarez and others, 2004, 2007) samplers are well suited to overcoming the difculties of measuring low analyte concentrations and recording episodic analyte loading. This report presents data obtained from SPMD and POCIS samplers deployed as part of a cooperative study being conducted by the U.S. Geological Survey and EWEB. This report is dynamic, and additional appendixes will be added as new data become available. Environmental Setting and Data-Collection Sites The environmental setting of the McKenzie River basin and a discussion of sampling sites in the basin have been previously reported in McCarthy and others (2009) and Kelly and others (2012). Sample Collection, Laboratory Methods, and Quality Assurance The methods used to collect, prepare, and analyze samples and to assure the quality of the data are presented in detail in McCarthy and others (2009). Methods are briey summarized and details specic to each data set are included as a “methods” worksheet in the data workbooks (see appendixes). SPMD and POCIS Data The SPMD and POCIS data are available in the appendixes of this report as Microsoft © Excel 2007 (.xlsx) les at http://pubs.usgs.gov/ds/692/. 2 Water-Quality Data from Semipermeable-Membrane Devices and Polar Organic Chemical Integrative Samplers, McKenzie River Basin, Oregon tac12-0735_fig01 Western Cascades High Cascades Willamette Valley 126 228 99 58 22 20 20 5 5 126 Blue River Reservoir McKenzie Trail Bridge Reservoir Cougar Reservoir Carmen Reservoir Lookout Point Lake Fall Creek Reservoir Clear Lake River 1,2 3 4 5 6 1,2 3 4 4 6 5 EXPLANATION Monitoring location Physiographic province Basin boundary High Cascades Eugene Springfield Leaburg Vida Coburg Walterville Belknap Springs 121°45'122°122°15'122°30'122°45'123°123°15' 44° 30' 44° 15' 44° 0 5KILOMETERS 0 5 MILES OREGON Study Area Base modified from U.S. Geological Survey (various scales) Projection: Oregon Lambert, North American Datum 1983 0 2 KILOMETERS 0 2 MILES 0 2 KILOMETERS 0 2 MILES Inset 1 Sites 1-4 Inset 2 Sites 5-6 See “Inset 1” Sites 1-4 See “Inset 2” Sites 5-6 Figure 1. Study area location and data‑collection sites, McKenzie River basin, Oregon. References Cited 3 References Cited Alvarez, D.A., 2010, Guidelines for the use of the semipermeable membrane device (SPMD) and the polar organic chemical integrative sampler (POCIS) in environmental monitoring studies: U.S. Geological Survey, Techniques and Methods 1–D4, 28 p. (Also available at http://pubs.usgs.gov/tm/tm1d4/.) Alvarez, D.A., Cranor, W.L., Perkins, S.D., Clark, R.C., and Smith, S.B., 2008a, Chemical and toxicological assessment of organic contaminants in surface water using passive samplers: Journal of Environmental Quality, v. 37, p. 1024-1033. Alvarez, D.A., Cranor, W.L., Perkins, S.D., Schroeder, V.L., Werner, S.L., Furlong, E.T., and Holmes, J., 2008b, Investigation of organic chemicals potentially responsible for mortality and intersex in sh of the North Fork of the Shenandoah River, Virginia, during spring of 2007: U.S. Geological Survey Open-File Report 2008-1093, 16 p. (Also available at http://pubs.er.usgs.gov/publication/ ofr20081093.) Alvarez, D.A., Huckins, J.N., Petty, J.D., Jones-Lepp, F., Stuer-Lauridsen, F., Getting, D.T., Goddard, J.P., and Gravell, A., 2007, Water sampling—Polar organic chemical integrative sampler (POCIS), in Greenwood, R., Mills, G., and Vrana, B., eds., Passive sampling techniques in environmental monitoring, 48: Amsterdam, Elsevier, p. 171–198. Alvarez, D.A., Petty, J.D., Huckins, J.N., Jones-Lepp, T.L., Getting, D.T., Goddard, J.P., and Manahan, S.E., 2004, Development of a passive, in situ, integrative sampler for hydrophilic organic contaminants in aquatic environments: Environmental Toxicology and Chemistry, v. 23, no. 7, p. 1640–1648. Eugene Water and Electric Board, 2000, Drinking water protection plan: Eugene, Oreg., Eugene Water and Electric Board Technical Report, 23 p., accessed April 20, 2012, at http://www.eweb.org/public/documents/water/ WaterProtectionPlan.pdf. Huckins, J.N., Petty, J.D., and Booij, K., 2006, Monitors of organic chemicals in the environment—semipermeable membrane devices: New York, Springer, 223 p. Keith, L.H., 1991, Environmental sampling and analysis—A practical guide: Boca Raton, Fla., CRC Press, Inc., p. 101-113. Kelly, V.J., Anderson, C.W., and Morgenstern, Karl, 2012, Reconnaissance of land-use sources of pesticides in drinking water, McKenzie River, Oregon: U.S. Geological Survey Scientic Investigations Report 2012-5091, 46 p. (Also available at http://pubs.usgs.gov/sir/2012/5091/.) McCarthy, K.A., Alvarez, David, Anderson, C.W., Cranor, W.L., Perkins, S.D., and Schroeder, Vickie, 2009, Evaluation of passive samplers for long-term monitoring of organic compounds in the untreated drinking water supply for the City of Eugene, Oregon, September–October 2007: U.S. Geological Survey Scientic Investigations Report 2009–5178, 20 p. (Also available at http://pubs.usgs.gov/ sir/2009/5178/.) Petty, J.D., Orazio, C.E., Huckins, J.N., Gale, R.W., Lebo, J.A., Meadows, J.C., Echols, K.R., and Cranor, W.L., 2000, Considerations involved with the use of semipermeable membrane devices for monitoring environmental contaminants: Journal of Chromatography A, v. 879, p. 83-95. 4 Water-Quality Data from Semipermeable-Membrane Devices and Polar Organic Chemical Integrative Samplers, McKenzie River Basin, Oregon This page intentionally left blank. [...]... Data from Passive Samplers Deployed in the Mckenzie River Basin, Oregon, During 2007 Appendix 1 is a Microsoft© Excel spreadsheet and is available for download at http://pubs.usgs.gov/ds/692/ Appendix 2 Data from Passive Samplers Deployed in the Mckenzie River Basin, Oregon, During 2010 Appendix 2 is a Microsoft© Excel spreadsheet and is available for download at http://pubs.usgs.gov/ds/692/ 6   Water-Quality. .. http://pubs.usgs.gov/ds/692/ 6   Water-Quality Data from Semipermeable-Membrane Devices and Polar Organic Chemical Integrative Samplers, McKenzie River Basin, Oregon This page intentionally left blank Publishing support provided by the U.S Geological Survey Publishing Network, Tacoma Publishing Service Center For more information concerning the research in this report, contact the Director, Oregon Water Science Center... contact the Director, Oregon Water Science Center U.S Geological Survey 2130 SW 5th Avenue Portland, Oregon 97201 http://or.water.usgs.gov McCarthy and others— Water-Quality Data from Semipermeable-Membrane Devices and Polar Organic Chemical Integrative Samplers, McKenzie River Basin, Oregon Data Series 692 Printed on recycled paper . paper McCarthy and others— Water-Quality Data from Semipermeable-Membrane Devices and Polar Organic Chemical Integrative Samplers, McKenzie River Basin, Oregon Data. 1. Data from Passive Samplers Deployed in the Mckenzie River Basin, Oregon, During 2007. 5 Appendix 2. Data from Passive Samplers Deployed in the Mckenzie

Ngày đăng: 14/03/2014, 20:20

Từ khóa liên quan

Mục lục

  • WATER-QUALITY DATA FROM SEMIPERMEABLE-MEBRANE DEVICES AND POLAR ORGANIC CHEMICAL INTEGRATIVE SAMPLER

  • Table of Contents

  • List of Figures

  • Conversion Factors, Datum, and Acronyms

  • Abstract

  • Introduction

  • Environmental Setting and Data‑Collection Sites

  • Sample Collection, Laboratory Methods, and Quality Assurance

  • SPMD and POCIS Data

  • References Cited

  • Appendix 1. Data from Passive Samplers Deployed in the Mckenzie River Basin, Oregon, During 2007.

  • Appendix 2. Data from Passive Samplers Deployed in the Mckenzie River Basin, Oregon, During 2010.

Tài liệu cùng người dùng

Tài liệu liên quan