Datasheet - FO - Cable - Outdoor - Armored JF fibre cable

Datasheet - FO - Cable - Outdoor - Armored JF fibre cable

Datasheet - FO - Cable - Outdoor - Armored JF fibre cable

... KRSI -JF- 510C-GSP Page 1 of 8 TECHNICAL SPECIFICATION LOOSE TUBE DESIGN, SINGLE JACKET/ SINGLE ARMOR, JELLY-FILLED, F/O CABLE KRSI -JF- 510C-GSP Page 2 of 8 1. SCOPE 1.1 ... method: TIA/EIA-45 5-3 3A -. Mandrel diameter: 30D (D = cable diameter) -. Short term tensile load: 2,700N for 1 hour -. Long term tensile load: 1,000N for 10 minutes # Acceptance Criteria -. Fiber stra...
Ngày tải lên : 22/10/2013, 11:15
  • 8
  • 315
  • 0
Datasheet - FO - Cable - Outdoor Fibre Cable, Dual Jacket

Datasheet - FO - Cable - Outdoor Fibre Cable, Dual Jacket

... CRITERIA Tensile Performance # Test method: IEC 79 4-1 -E1 -. Mandrel diameter: 30D (D = cable diameter) -. Tensile load: 2,700N for 1 hour # Acceptance Criteria -. Fiber strain: ≤ 0.33% -. Attenuation ... 23 TECHNICAL SPECIFICATION Cable Specification No.: KGST-200 2-0 14 OPTICAL FIBRE CABLE LOOSE TUBE / JELLY FILLED DOUBLE JACKET / SINGLE ARMORED (LTD ARM CABLE) 2...
Ngày tải lên : 22/10/2013, 11:15
  • 8
  • 298
  • 0
Datasheet - FO - cable - Optic Outdoor Armor Cable LSZH STA 30Mar04

Datasheet - FO - cable - Optic Outdoor Armor Cable LSZH STA 30Mar04

... method: TIA/EIA-45 5-3 3A -. Mandrel diameter: 30D (D = cable diameter) -. Short term tensile load: 2,700N for 1 hour -. Long term tensile load: 1,000N for 10 minutes # Acceptance Criteria -. Fiber strain: ... method: TIA/EIA-45 5-8 5A -. Cable length twisted: 2m -. No. of twist cycles: 10 cycles -. Twist angle: ±180˚ # Acceptance Criteria -. Attenuation Increm...
Ngày tải lên : 18/10/2013, 13:15
  • 8
  • 330
  • 0
Datasheet - FO - Cable - Outdoor, Armor, PE Jacketed

Datasheet - FO - Cable - Outdoor, Armor, PE Jacketed

... covers the general requirements for fiber optic telecommunication cables used for inter-building backbone in duct, direct buried and lashed aerial installation. 1.2 Cable Description 1) Jelly ... section shall be performed at 1550nm for single mode fiber (SM) and at 1300nm for multi mode fiber (MM). Table 5. The Mechanical and Environmental Performance of the Cable ITEMS TES...
Ngày tải lên : 26/10/2013, 18:15
  • 8
  • 272
  • 0
Datasheet - FO - Cable - Outdoor, Loose Tube, PE Jacketed

Datasheet - FO - Cable - Outdoor, Loose Tube, PE Jacketed

... Armored Crush Resistance (EIA-FOTP-41A): 900 N/cm 900 N/cm Impact Resistance (EIA-FOTP-25B): 100 impacts 100 impacts Flexing (EIA-FOTP-104A): 1000 cycles 100 cycles Maximum Pulling Load (EIA-FOTP-33A): ... O.D.* Unloaded: 10 x cable O.D* 10 x cable O.D.* Fiber Proof Test: 100 KPSI 100 KPSI Operating Temperature: -4 0°C to +70°C -4 0°C to +70°C Storage Temperature (non-flexing):...
Ngày tải lên : 26/10/2013, 18:15
  • 2
  • 317
  • 0
Tài liệu Datasheet - FO - Cable - In & Outdoor Loose Tube - HIGHLIGH doc

Tài liệu Datasheet - FO - Cable - In & Outdoor Loose Tube - HIGHLIGH doc

... HIGHLIGHT ® Outdoor Loose Tube Multimode & Singlemode Fibre Cable
Ngày tải lên : 09/12/2013, 15:15
  • 2
  • 430
  • 1
Tài liệu Datasheet - FO - Cable - Fibre Distribution Cables docx

Tài liệu Datasheet - FO - Cable - Fibre Distribution Cables docx

... Resistance: EIA-FOTP-41A 400 N/cm 400 N/cm 400 N/cm 400 N/cm 400 N/cm Impact Resistance: EIA-FOTP-25B 50 Impacts 100 Impacts 50 Impacts 500 Impacts 500 Impacts Flexing: EIA-FOTP-104A 1000 Cycles ... Passes @ 0°C and 70°C Cable Twist Test: EIA-FOTP-85A — — — 1000 Cycles 1000 Cycles Operating Temperature: -2 0°C to +70°C -2 0°C to +70°C 0°C to +70°C -2 0°C to +70°C (OFNR) -2 0°C t...
Ngày tải lên : 11/12/2013, 13:15
  • 2
  • 337
  • 0
Tài liệu Datasheet - FO - Cable - LTS ARM JF Single Armor LOOSE TUBE DESIGN, SINGLE JACKET/ SINGLE ARMOR, JELLY-FILLED, F/O CABLELSZH jacket docx

Tài liệu Datasheet - FO - Cable - LTS ARM JF Single Armor LOOSE TUBE DESIGN, SINGLE JACKET/ SINGLE ARMOR, JELLY-FILLED, F/O CABLELSZH jacket docx

... KRSI -JF- 510C-GSP Page 1 of 8 TECHNICAL SPECIFICATION LOOSE TUBE DESIGN, SINGLE JACKET/ SINGLE ARMOR, JELLY-FILLED, F/O CABLE KRSI -JF- 510C-GSP Page 2 of 8 1. SCOPE 1.1 ... breakage KRSI -JF- 510C-GSP Page 6 of 8 Table 5. The Mechanical and Environmental Performance of the Cable (continued) ITEMS TEST METHOD AND ACCEPTANCE CRITERIA Cable Twist Test # Test method: TIA/EIA-45 5-8 5...
Ngày tải lên : 21/12/2013, 19:15
  • 8
  • 415
  • 0
Tài liệu Datasheet - FO - Cable - Central Tube 50-125um 0M3 armored ppt

Tài liệu Datasheet - FO - Cable - Central Tube 50-125um 0M3 armored ppt

... marking 6.2 Cable Re-marking The re-marking shall be indent-marked, preferably with yellow characters, on the outer cable sheath. Any cable that contains two sets of cable markings shall ... PERFORMANCE AND TESTS 5.1 Temperature Range For the cables covered by this specification, the following temperature ranges apply: Operation : -2 0°C to +60°C Installation...
Ngày tải lên : 16/01/2014, 20:21
  • 7
  • 211
  • 0
Tài liệu Datasheet - FO - Cable - Fibre Distribution Cables pdf

Tài liệu Datasheet - FO - Cable - Fibre Distribution Cables pdf

... Resistance: EIA-FOTP-41A 400 N/cm 400 N/cm 400 N/cm 400 N/cm 400 N/cm Impact Resistance: EIA-FOTP-25B 50 Impacts 100 Impacts 50 Impacts 500 Impacts 500 Impacts Flexing: EIA-FOTP-104A 1000 Cycles ... Passes @ 0°C and 70°C Cable Twist Test: EIA-FOTP-85A — — — 1000 Cycles 1000 Cycles Operating Temperature: -2 0°C to +70°C -2 0°C to +70°C 0°C to +70°C -2 0°C to +70°C (OFNR) -2 0°C t...
Ngày tải lên : 16/01/2014, 20:21
  • 2
  • 363
  • 0

Xem thêm

Từ khóa: