small signal stability and power system oscillations

Electrical machinery and power system fundamentals

Electrical machinery and power system fundamentals

Ngày tải lên : 05/03/2016, 14:09
... Find the real and reactive powers supplied to each load (d) Find the real and reactive power losses in the transmission line (e) Find the real power, reactive power, and power factor supplied by ... cos θ (e) The real and reactive power supplied by the generator when the switch is closed is just the sum of the real and reactive powers of Loads 1, 2, and The powers of Loads and have already ... one-line diagram of a simple power system containing a single 480 V generator and three loads Assume that the transmission lines in this power system are lossless, and answer the following questions...
  • 337
  • 439
  • 0
Energy, exergy and environmental analysis of a hybrid combined cooling heating and power system utilizing biomass and solar energy

Energy, exergy and environmental analysis of a hybrid combined cooling heating and power system utilizing biomass and solar energy

Ngày tải lên : 29/07/2016, 14:01
... solar-assisted biomass energy system for heating [17], a hybrid solar and biomass energy complementary system for power generation [18], a hybrid solar and chemical looping combustion system for solar thermal ... photothermal collection subsystem, internal combustion engine (ICE) power subsystem and waste heat utilization subsystem Biomass material is first gasified in the downdraft gasifier, and then its product ... section, and qv and Tv are the density and temperature of the vapor, respectively hlv (kJ/kg) is the latent heat of vaporization, and Psat and Pa (kPa) are the pressures of the saturated vapor and...
  • 12
  • 428
  • 0
power system stability and control chuong (1)

power system stability and control chuong (1)

Ngày tải lên : 21/03/2014, 12:11
... examples of disturbance data in books such as The BMI Handbook of Power Signatures, Second Edition, and the Dranetz Field Handbook for Power Quality Analysis ß 2006 by Taylor & Francis Group, ... be used in conjunction with power quality monitors to find a solution to the problem 33.4 Summary Most power quality problems can be solved with simple hand-tools and attention to detail Some ... absence of standards, several manufacturers have developed proprietary ‘‘flicker’’ meters In recent years, an effort has been made to standardize the definition of ‘‘flicker,’’ and to standardize the...
  • 8
  • 522
  • 3
power system stability and control chuong (2)

power system stability and control chuong (2)

Ngày tải lên : 21/03/2014, 12:11
... Distribution System Modeling and Analysis William H Kersting 22 Power System Operation and Control George L Clark and Simon W Bowen 23 Hard to Find Information (on Distribution System Characteristics and ... The Engineering Handbook, Third Edition, Richard C Dorf The Handbook of Formulas and Tables for Signal Processing, Alexander D Poularikas The Handbook of Nanoscience, Engineering, and Technology, ... this handbook This volume of the handbook is devoted to the subjects of electric power generation by both conventional and nonconventional methods, transmission systems, distribution systems, power...
  • 14
  • 498
  • 5
power system stability and control chuong (3)

power system stability and control chuong (3)

Ngày tải lên : 21/03/2014, 12:11
... Oklahoma, and Texas), the winds are strongest in the spring (March and April) and weakest in the summer (July and August) Utilities here are summer peaking, and hence need the most power when ... hospitals, schools, and the like, then it follows that wind turbines should be as efficient as possible Economies of scale and costs of operation and maintenance are such that the small, grid connected ... 1-4 Land Rights The wind is a free, clean, and inexhaustible energy source It has served humankind well for many centuries by propelling ships and driving wind turbines to grind grain and pump...
  • 10
  • 611
  • 3
power system stability and control chuong (4)

power system stability and control chuong (4)

Ngày tải lên : 21/03/2014, 12:11
... a result, the compressor and the expander must operate at the same time and must have the same air mass flow rate In the case of a CAES plant, the compressor and the expander can be sized independently ... Group, LLC systems are quiet and non-polluting, and can be installed near load centers and existing suburban substations These have round-trip AC–AC efficiencies in the range of 85%, and can respond ... but the compressor and the expander operate independently In a combustion turbine, the air that is used to drive the turbine is compressed just prior to combustion and expansion and, as a result,...
  • 8
  • 328
  • 0
power system stability and control chuong (5)

power system stability and control chuong (5)

Ngày tải lên : 21/03/2014, 12:11
... of their total customer demand Some of these systems have been residential and commercial rooftop systems and other systems have been larger ground-mounted systems PV systems are generally classified ... Stand-alone PV systems are used when it is impractical to connect to the utility grid Common standalone systems include PV-powered fans, water pumping systems, portable highway signs, and power ... into the system Stand-alone systems also often incorporate battery storage to run the system under low sun or no sun conditions 3.2.2.1 PV-Powered Fans Perhaps the simplest of all PV systems is...
  • 8
  • 480
  • 0
power system stability and control chuong (6)

power system stability and control chuong (6)

Ngày tải lên : 21/03/2014, 12:11
... machine, for damping power system dynamic oscillations [see Power System Stability and Control, Kundur (1994) and Section of title Power System Stability and Control of this handbook.] Various auxiliary ... acceleration during system fault conditions [see Power System Stability and Control, Kundur (1994) and Section of title Power System Stability and Control of this handbook.] 4.2.4 Generator Terminal Equipment ... speed and power output of the turbine generator The governor system includes setpoint and sensing equipment for speed, power and actuator position, compensation circuits, and hydraulic power...
  • 14
  • 448
  • 0
power system stability and control chuong (7)

power system stability and control chuong (7)

Ngày tải lên : 21/03/2014, 12:11
... these criteria, and the knowledge of the stator current and cooling system effectiveness, the manufacturer can project the motor component heating, and thus insulation life, and the efficiency ... torsional oscillation and to suppress harmonic variation in the magnetic waveform In a motor, heavy bars and end connections are required in the pole face to minimize and withstand the high heat ... value, or is controlled to regulate power factor, motor current, or system stability In addition, the rotor also has shaft-mounted fans or blowers for cooling and heat removal from the unit plus...
  • 8
  • 357
  • 1
power system stability and control chuong (8)

power system stability and control chuong (8)

Ngày tải lên : 21/03/2014, 12:11
... DC Auxiliary Power Systems for Generating Stations Switchgear IEEE Standards Collection: Power and Energy-Switchgear, 1998 Edition Auxiliary Transformers IEEE Distribution, Power and Regulating ... generator will be supplied as a unit The size and characteristics are usually determined by the system planners as a result of system load requirements and system stability requirements ß 2006 by Taylor ... egress lighting and lighting requirements for plant maintenance 6.6 DC Systems The plant will require at least one DC system for control and operation of essential systems when off-site power is lost...
  • 8
  • 371
  • 0
power system stability and control chuong (9)

power system stability and control chuong (9)

Ngày tải lên : 21/03/2014, 12:11
... possibility of ‘‘islanding’’ a portion of the system Small: Between large and extremely small Extremely small: Generation less than 100 kVA Location on the system and individual system characteristics ... automotive and transportation markets These experiments later expanded into markets associated with military and commercial aircraft and mobile systems Microturbines are typically defined as systems ... services and are essential for the reliability and operation of the electric power system The electrical services that are supported include generating capacity, energy supply, and the power delivery...
  • 10
  • 392
  • 0
power system stability and control chuong (10)

power system stability and control chuong (10)

Ngày tải lên : 21/03/2014, 12:11
... Highvoltage and extra-high-voltage (EHV) transmission lines interconnect power plants and loads, and form an electric network Figure 8.4 shows a typical high-voltage and EHV system This system contains ... the system through a switch is the most frequently used voltage control method The capacitor reduces lagging -power- factor reactive power and improves the power factor This increases voltage and ... Impacts upon Power System Operation John G Kappenman 16-1 Introduction Power Grid Damage and Restoration Concerns Weak Link in the Grid: Transformers An Overview of Power System Reliability...
  • 14
  • 398
  • 0
power system stability and control chuong (11)

power system stability and control chuong (11)

Ngày tải lên : 21/03/2014, 12:11
... consideration as an International Standard References Carton, T and Peyrot, A., Computer Aided Structural and Geometric Design of Power Lines, IEEE Trans on Power Line Syst., 7(1), 1992 Dreyfuss, ... Valley, Electric Light and Power Magazine, 48(vii), 55–58, 1971 12 Pohlman, J and Lummis, J., Flexible Structures Offer Broken Wire Integrity at Low Cost, Electric Light and Power, 46(V, 144–148.4), ... highly controversial installations (Pohlman and Harris, 1971) Parents of small children and safety engineers often raise the issue of lattice masts, towers, and guys, constituting an ‘‘attractive...
  • 12
  • 338
  • 0
power system stability and control chuong (12)

power system stability and control chuong (12)

Ngày tải lên : 21/03/2014, 12:11
... Lines and Substations Transmission line and substation insulation integrity is one of the most dominant factors in power system reliability We will describe typical transmission lines and substations ... energization and resonance, cause power frequency, or close-to -power frequency, and relatively long duration overvoltages The duration is from sec to several minutes The expected peak amplitudes and duration ... Transmission Line Reference Book (345 kV and Above), 2nd ed., EL 2500 Electric Power Research Institute (EPRI), Palo Alto, CA, 1987 Fink, D.G and Beaty, H.W., Standard Handbook for Electrical Engineers,...
  • 20
  • 898
  • 0
power system stability and control chuong (13)

power system stability and control chuong (13)

Ngày tải lên : 21/03/2014, 12:11
... realized and maximum safety of personnel is attained, properly designed and constructed tools and equipment are tantamount to a successful job Because the initial cost of these tools and equipment ... conductors being strung and pulling cables being used, or fully insulating equipment and operator, isolating equipment and personnel All equipment, conductors, anchors, and structures within a ... was physically able to withstand the tensions of lowering it to the ground By utilizing a helicopter and bare-hand work methods, the spacers were able to be replaced and the conductor strengthened...
  • 8
  • 301
  • 0
power system stability and control chuong (14)

power system stability and control chuong (14)

Ngày tải lên : 21/03/2014, 12:11
... Radial system and (B) looped system A radial system has the lowest initial cost, because a looped system requires the additional facilities to the second source Outage restoration on a radial system ... direct buried low-voltage power cables 12.4 Medium- and High-Voltage Power Cables Medium- and high-voltage power cables, in addition to being insulated, are shielded to contain and evenly distribute ... Separable Insulated Connector Systems for Power Distribution Systems above 600 V Insulated Cable Engineering Association, ICEA standards P-53-426, Ampacities, 15–69 kV 1=c Power Cable Including Effect...
  • 10
  • 366
  • 0
power system stability and control chuong (15)

power system stability and control chuong (15)

Ngày tải lên : 21/03/2014, 12:11
... Devices and Power Systems, John Wiley and Sons, Inc., New York, 1994 Glover, J.D and Sarma, M.S., Power System Analysis and Design, 3rd ed., Brooks=Cole, 2002 Stevenson, W.D Jr., Elements of Power System ... H., Power System Analysis, McGraw-Hill, Boston, MA, 1999 Gross, Ch.A., Power System Analysis, John Wiley and Sons, New York, 1979 Gungor, B.R., Power Systems, Harcourt Brace Jovanovich, Orlando, ... Zaborszky, J and Rittenhouse, J.W., Electric Power Transmission The Power System in the Steady State, The Ronald Press Company, New York, 1954 Barnes, C.C., Power Cables Their Design and Installation,...
  • 28
  • 530
  • 0
power system stability and control chuong (16)

power system stability and control chuong (16)

Ngày tải lên : 21/03/2014, 12:11
... with stranding as follows: 27.5 Â 106 for single-strand core 27.0 Â 106 for 7-strand core 26.5 Â 106 for 19-strand core Using elastic moduli of 8.6 and 27.0 million psi for aluminum and steel, ... Final sags and tensions depend on initial installed sags and tensions and on proper handling during installation The final sag shape of conductors is used to select support point heights and span ... initial and final loading conditions Initial sags and tensions are simply the sags and tensions at the time the line is built Final sags and tensions are calculated if (1) the specified ice and wind...
  • 42
  • 950
  • 0
power system stability and control chuong (17)

power system stability and control chuong (17)

Ngày tải lên : 21/03/2014, 12:11
... the measuring point from the phases B and C of the line are 2.64 Â 10À7 and 1.69 Â 10À7 W=m2, respectively, and the corresponding noise levels are 54.33 and 52.38 dBA The total noise level is ... discharge current consists of regular negative pulses of small amplitude and short duration, succeeding one another at the rate of a few thousand pulses per second A typical Trichel current pulse ... changes polarity and reverses the ionic movement For direct current (DC) lines, the ion displacement covers the whole distance separating the line conductors, and between the conductors and the ground...
  • 22
  • 383
  • 0

Xem thêm