ms for cable construction

Lab 3.1.9c Rollover Cable Construction

Lab 3.1.9c Rollover Cable Construction

Ngày tải lên : 16/10/2013, 20:15
... help create a rollover console cable. Signal Legend: RTS = Request To Send, DTR = Data Terminal Ready, TxD = Transmit Data, GND = Ground (One for TxD and one for RxD), RxD = Receive Data, ... (12 in.) to the distance. Make the cable about 3.05 m (10 ft), unless connecting to router or switch from a greater distance. The maximum length for this cable is about 8m (approx 25 ft). Step ... 5.08 cm (2 in.) of jacket off of one end of the cable. Step 4 Hold the 4 pairs of twisted cables tightly where jacket was cut away. Reorganize the cable pairs and wires into the order of the...
  • 3
  • 369
  • 0
Lab 3.1.9d Rollover Cable Construction

Lab 3.1.9d Rollover Cable Construction

Ngày tải lên : 19/10/2013, 02:15
... help create a rollover console cable. Signal Legend: RTS = Request To Send, DTR = Data Terminal Ready, TxD = Transmit Data, GND = Ground (One for TxD and one for RxD), RxD = Receive Data, ... (12 in.) to the distance. Make the cable about 3.05 m (10 ft), unless connecting to router or switch from a greater distance. The maximum length for this cable is about 8m (approx 25 ft). Step ... 5.08 cm (2 in.) of jacket off of one end of the cable. Step 4 Hold the 4 pairs of twisted cables tightly where jacket was cut away. Reorganize the cable pairs and wires into the order of the...
  • 3
  • 297
  • 0
Lab 3.1.9d Crossover Cable Construction

Lab 3.1.9d Crossover Cable Construction

Ngày tải lên : 19/10/2013, 02:15
... it. Standard lengths for this cable are 1.83 m (6 ft) and 3.05 m (10 ft). Step 3 Cut a piece of stranded UTP cable to the desired length. Use stranded cable for patch cables because it is ... Lab 3.1.9d Copyright  2003, Cisco Systems, Inc. Step 5 Hold the four pairs of twisted cables tightly where the jacket was cut away. Reorganize the cable pairs into the order of the 568-B ... terminate the other end of the cable using the 568-A scheme to finish the crossover cable. 2 - 4 CCNA 1: Networking Basics v 3.0 - Lab 3.1.9d Copyright  2003, Cisco Systems, Inc. Step 2...
  • 4
  • 302
  • 0
Lab 3.1.9e Crossover Cable Construction

Lab 3.1.9e Crossover Cable Construction

Ngày tải lên : 23/10/2013, 00:15
... Cut a piece of stranded UTP cable to the desired length. Use stranded cable for patch cables because it is more durable when bent repeatedly. Solid wire is fine for cable runs that are punched ... Cisco Systems, Inc. Lab 3.1.9e Crossover Cable Construction Objective • Build a Category 5 or Category 5e (CAT 5 or 5e) Unshielded Twisted Pair (UTP) Ethernet crossover cable to T568-B ... standards. • Test the cable for continuity and correct pin-outs, correct wire on the right pin. Background This will be a 4-pair "crossover" cable. A crossover cable means that the...
  • 4
  • 263
  • 0
Tài liệu Lab 3.1.9b Straight-Thru Cable Construction pptx

Tài liệu Lab 3.1.9b Straight-Thru Cable Construction pptx

Ngày tải lên : 24/01/2014, 19:20
... the cable for continuity and correct pinouts, the correct color of wire on the right pin. Background The cable constructed will be a 4-pair "straight thru" cable. A straight thru cable ... Systems, Inc. Lab 3.1.9b Straight-Thru Cable Construction Objective • Build a Category 5 or Category 5e (CAT 5 or 5e) Unshielded Twisted Pair (UTP) Ethernet network patch cable ... cutters Cabling Pin-out Information for T568-B 3 - 3 CCNA 1: Networking Basics v 3.0 - Lab 3.1.9b Copyright  2003, Cisco Systems, Inc. Step 4 Hold the four pairs of twisted cables tightly where...
  • 3
  • 329
  • 0
Tài liệu Lab 3.1.9c Straight-Through Cable Construction pptx

Tài liệu Lab 3.1.9c Straight-Through Cable Construction pptx

Ngày tải lên : 24/01/2014, 19:20
... piece of stranded Cat UTP cable to the desired length. Use stranded cable for patch cables because it is more durable when bent repeatedly. Solid wire is used for cable runs that are punched ... Systems, Inc. Lab 3.1.9c Straight-Through Cable Construction Objective • Build a Category 5 or Category 5e (CAT 5 or 5e) Unshielded Twisted Pair (UTP) Ethernet network patch cable ... • Test the cable for continuity and correct pinouts, the correct color of wire on the right pin. Background The cable constructed will be a four-pair, eight-wire, straight-through cable, which...
  • 3
  • 326
  • 0
Báo cáo y học: "MALDI-TOF MS Combined With Magnetic Beads for Detecting Serum Protein Biomarkers and Establishment of Boosting Decision Tree Model for Diagnosis of Colorectal Cancer"

Báo cáo y học: "MALDI-TOF MS Combined With Magnetic Beads for Detecting Serum Protein Biomarkers and Establishment of Boosting Decision Tree Model for Diagnosis of Colorectal Cancer"

Ngày tải lên : 25/10/2012, 11:18
... limited sensitivity (30-40%) for early CRC diagnosis [9]. It should be noted that none of these existed serum markers could be used individually for screening for CRC with suf- ficient accuracy ... proteomic research because of its high sensitivity for proteins in low molecular weight range and the capability for high throughput screening, even for proteins with extreme characteristics (highly ... differentially expressed proteins was advo- cated for biomarkers of diagnosis for colorectal can- cer. Materials and methods Patients Experiment was performed in Taizhou Munici- pal Hospital, Zhejiang,...
  • 9
  • 530
  • 1
Valuating & Adjusting Strategy  For Construction Installation & Industrial Material Company Limited

Valuating & Adjusting Strategy For Construction Installation & Industrial Material Company Limited

Ngày tải lên : 16/04/2013, 10:29
... am very thankful to all individuals for providing me with the necessary information and supporting me with advice during the period of my data collection for this research study. Last but not ... 26 Table 4: Strengths and Weaknesses of CIM CO., LTD 34 Table 6: SWOT/TOWS matrix of MSA VN 37 To choose Strategy applied for Cim, the author use pointing method with criteria above. The scale point ... 38 Written by Duong Ngoc Khanh MBM7 3 Valuating & Adjusting Strategy for Cim Co., Ltd With an unstable environment like above, Construction Installation & Industrial Material Company Limited...
  • 6
  • 421
  • 1
Project Management for Construction Chapter 1

Project Management for Construction Chapter 1

Ngày tải lên : 24/10/2013, 08:15
... for readers attempting some of the problems in Chapters 4 to 14. Numerous software programs could be used for this purpose, including both spreadsheet and equation solving programs. Problems ... firms that perform construction work for others, and is estimated to be approximately 85% of all construction 1 Project Management for Construction Fundamental Concepts for Owners, Engineers, ... the post -construction facility financing will be arranged by the owner. Construction loans provided for different types of construction vary. In the case of residential housing, construction...
  • 26
  • 786
  • 1
Project Management for Construction Chapter 2

Project Management for Construction Chapter 2

Ngày tải lên : 24/10/2013, 08:15
... identified only with the supporting disciplines. For example, computer-based information systems and decision support systems are now common-place tools for general management. Similarly, many operations ... performance. Artificial intelligence has also begun to be applied to provide decision support systems for solving ill-structured problems in management. The behavioral science approach for ... equipment and the work of all construction contractors, and monthly payments to contractors, changes, claims and inspection for conforming design requirements. • Perform other project related...
  • 24
  • 704
  • 0