design of lpg installations

SAP2000®  Linear and Nonlinear  Static and Dynamic  Analysis and Design  of  Three-Dimensional Structures

SAP2000® Linear and Nonlinear Static and Dynamic Analysis and Design of Three-Dimensional Structures

Ngày tải lên : 06/09/2012, 15:56
... 1 - 2 Overview of the Program 1 Overview of the Program SAP2000 is a stand-alone finite-element-based structural program for the analysis and design of civil structures. It offers an intuitive, ... Property Type for Add area of the form. Scroll down the list of import options until you find Import Double Angle – see Figure 7. Single click on it. D. In the Click to area of the Frame Properties ... to read this manual on your computer screen. During the course of this tutorial, we will explore many of the basic fea- tures of SAP2000. Prepare to spend at least one hour going through this...
  • 47
  • 1.4K
  • 2
SAP2000 Integrated Finite Elements Analysis and Design of Structures

SAP2000 Integrated Finite Elements Analysis and Design of Structures

Ngày tải lên : 06/09/2012, 15:56
... Select Mode. 24. Click the roof beam at the top of the braced frame to select it. Also click the joint at the top of the chevron brace (center of braced frame roof beam) to select it. 25. From ... C-10 to enter the last roof beam. The model now appears as shown in Figure C-11. Figure C-11: Model After All Roof Level Beams Have Been Drawn 18. Select all of the roof level frame elements and ... Span Loads Used In SAP2000 Model Roof Beams 39, 40, 51, 52 0.40 klf DL 0.12 klf LL Roof Beams 41/44, 42, 47/50, 49 Roof Beams 45, 46 0.48 klf DL 0.24 klf LL Roof Beams 43, 48 Second Floor Beams...
  • 127
  • 1.5K
  • 2
The design of mat foundations

The design of mat foundations

Ngày tải lên : 16/10/2012, 10:43
... being designed for a small office building with a total live load of 250 kips and dead load of 500 kips. Find: (a) the depth D f for a fully compensated foundation, (b) the depth D f if a soft ... of the clay layer, z/B = 18 ft / 40 ft = 0.45 and L/B = 60 ft / 40 ft = 1.50 2) At the middle of the clay layer, z / B = 22 ft / 40 ft = 0.55 and L/B = 60 ft / 40 ft = 1.50 3) At the bottom of ... 0.25 eo = 0.9 density (sat) = 119 pcf Example 4. Design the steel lying in the East-West direction of the mat shown below with external dimensions of 42 feet by 74 feet. The columns are all 15”by...
  • 65
  • 657
  • 0
Theory and Design of Electrical and Electronic Circuits

Theory and Design of Electrical and Electronic Circuits

Ngày tải lên : 23/10/2013, 16:15
... Chap. 10 Amplification of Audiofrecuenciy on high level classes A and B Chap. 11 Amplification of Radiofrecuency in low level class A Chap. 12 Amplification of Radiofrecuency in low level ... pulses. For this reason we have the series of following equations of design finally Chap. 05 Transformers of small value Generalities Designe of transformers Solenoidal onelayer Solenoidal ... Generalities Q- meter Design of inductors Oneloop Solenoidal onelayer Toroidal onelayer Solenoidal multilayer Design of inductors with nucleus of ferrite Shield to solenoidal multilayer inductors Design Choke...
  • 493
  • 797
  • 6
Electronics - Theory and Design of Electrical and Electronic Circuits

Electronics - Theory and Design of Electrical and Electronic Circuits

Ngày tải lên : 27/10/2013, 16:15
... Transformadores of great value Equivalent circuit of a transformer Equivalent circuit of a inductor Measurement of the characteristics Transformer of alimentation Design Transformer of audiofrecuency Transformer ... copper of the wire of the primary R 2 resistance of the copper of the wire of the secondary R 0 resistance of losses for Foucault and hysteresis C 1 distributed capacitance of the winding of ... Polarization of components Bipolar transistor of junction (TBJ) Theory Design Fast design Unipolar transistor of junction (JFET) Theory Design Operational Amplifier of Voltage (AOV) Theory Design ...
  • 493
  • 734
  • 2
Tài liệu Design of a USB Device Driver ppt

Tài liệu Design of a USB Device Driver ppt

Ngày tải lên : 13/12/2013, 00:15
... code execution of critical routines Optimize code execution of critical routines – – Design a solution with parallelism of processing and data Design a solution with parallelism of processing ... depth multiple packet depth – – Hardware Retry of Packet Transfers on error Hardware Retry of Packet Transfers on error Key Features of a USB Controller Key Features of a USB Controller 18 ? ? Hardware ... controls camera via control or bulk endpoints. bulk endpoints. – – Design of the communications protocol is contingent Design of the communications protocol is contingent on the Twain data source...
  • 28
  • 423
  • 0
Tài liệu Design of Sheet Pile Walls doc

Tài liệu Design of Sheet Pile Walls doc

Ngày tải lên : 13/12/2013, 11:15
... depth of penetration of the piling or by a combination of penetration and anchor position for an anchored wall. Because of the complex- ity of behavior of the wall/soil system, a number of simplifying ... before design of the system can commence. (1) Elevation at the top of the sheet piling. (2) The ground surface profile extending to a mini- mum distance of 10 times the exposed height of the wall ... load 4-5 CECW-ED Engineer Manual 1110-2-2504 Department of the Army U.S. Army Corps of Engineers Washington, DC 20314-1000 EM 1110-2-2504 31 March 1994 Engineering and Design DESIGN OF SHEET PILE WALLS Distribution...
  • 75
  • 597
  • 2
Tài liệu Design Of Fuzzy Controllers doc

Tài liệu Design Of Fuzzy Controllers doc

Ngày tải lên : 23/12/2013, 02:17
... terms are the same as before. Now the 20 Design Of Fuzzy Controllers Jan Jantzen jj@iau.dtu.dk: 1 $EVWUDFW Design of a fuzzy controller requires more design decisions than usual, for example regarding ... universe by means of parameters. A discrete membership function is defined in terms of a vector with a finite number of elements. In the latter case it is necessary to specify the range of the universe ... example of a controller that finds the rules itself. Neural networks is another possibility. There is no design procedure in fuzzy control such as root-locus design, frequency re- sponse design, ...
  • 27
  • 404
  • 0
Tài liệu The Design of Rolling Bearing Mountings P2 ppt

Tài liệu The Design of Rolling Bearing Mountings P2 ppt

Ngày tải lên : 25/12/2013, 05:17
... italics. At the end of this publication they are summarized and explained in a glossary of terms, some supplemented by illustrations. The Design of Rolling Bearing Mountings Design Examples covering ... maximum cutting load of 0.9 kN, axial – shaft weight and spring preload of 0.2 kN. Maximum load on the drive end bearing: radial – maximum belt pull of 0.4 kN, axial – spring preload of 0.5 kN. Bearing ... compensated for by inclining of rolls 1 and 3 and by counterbending of rolls 2 and 4. Moreover, the narrow tolerance of the foil thickness requires a high radial runout accuracy of the bearings and adequate...
  • 20
  • 528
  • 0
Tài liệu The Design of Rolling Bearing Mountings P1 pptx

Tài liệu The Design of Rolling Bearing Mountings P1 pptx

Ngày tải lên : 25/12/2013, 05:17
... standard-gauge locomotive The Design of Rolling Bearing Mountings Design Examples covering Machines, Vehicles and Equipment Publ. No. WL 00 200/5 EA FAG OEM und Handel AG A company of the FAG Kugelfischer ... arranged. Bearing selection The axial load of 130 kN is made up of the weight of the rotor and the two variable top and bottom fan im- pellers as well as the thrust of these fan impellers. They are supported ... basis of several load cases with variable loads, speeds and per- centage times. The locating bearing of the WKA60 plant is subjected to radial loads of F r = 400 1,850 kN and thrust loads of F a =...
  • 30
  • 602
  • 1

Xem thêm