Case Study - PBE - Data Center - Next Links ISP Data Centres

Case Study - PBE - Data Center - Next Links ISP Data Centres

Quản trị mạng

... more throughput and a reduction in attenuation But the upgrades to the NEXTLINK data Chris Hutchison, one of center Network Dynamics’ senior infrastructure were far from branch ordinary It was an ... base ted with the new structured cabling KRONE’s TrueNet C6T™ cabling in Network solution Both KRONE and Dynamics applaud The installer, Network an Ultim8™ block to HighBand™ jack NEXTLINK for ... show that to your customers? ticular piece of technology in the data error center can connect to any other tech- since it allows data to nology with a simple and quick patch- travel throughout...
  • 4
  • 326
  • 0
Designing an Optimized Data Center

Designing an Optimized Data Center

Quản trị mạng

... Help: TIA-9 42 TIA-9 42, Telecommunications Infrastructure Standard for Data Centers, a standard that has yet to be released as of this writing (May, 20 04), offers guidance on data center layout ...  Cables x 0. 0 62 5 square inches (cable diameter) x 1.30 = Cable Management Requirement Example350 cables x 0. 0 62 5 x 1.30 = 28 .44 square inches (minimum cable management of 6 x 6 or 4” x 8) ... discussion on cooling Figure Data Center with Flexible White Space Page  Designing an Optimized Data Center Cable Management The key to cable management in the optimized data center is understanding...
  • 12
  • 372
  • 2
Data Center: Infrastructure Architecture SRND

Data Center: Infrastructure Architecture SRND

Quản trị mạng

... message-digest area 10 range 10 .20 .0.0 25 5 .25 5.0.0 area 10 range 10 .21 .0.0 25 5 .25 5.0.0 network 10.0.0.0 0.0.0 .25 5 area network 10 .20 .0.0 0.0 .25 5 .25 5 area 10 network 10 .21 .0.0 0.0 .25 5 .25 5 area 10 The convergence ... subnets passive-interface Vlan20 network 10.10.10.0 0.0.0 .25 5 area 10 network 10 .20 .3.0 0.0.0 .25 5 area 10 network 10 .20 .20 .0 0.0.0 .25 5 area 10 network 10 .21 .0.0 0.0 .25 5 .25 5 area 10 The route cost ... the data center subnets to the core Data Center: Infrastructure Architecture SRND 2- 2 9 565 13 Chapter Data Center Infrastructure Design Routing Between the Data Center and the Core Figure 2- 2 Internet...
  • 130
  • 345
  • 0
Tài liệu Server Farm Security in the Business Ready Data Center Architecture v2.0 pdf

Tài liệu Server Farm Security in the Business Ready Data Center Architecture v2.0 pdf

Quản trị mạng

... Using VACLs 7 -2 VACL Command Syntax IP 7 -2 IPX 7-3 MAC 7-3 VACL Capture 7-4 6- 20 6- 63 6- 68 7-1 7-1 7 -2 Server Farm Security in the Business Ready Data Center Architecture v2.0 OL- 724 7-01 vii Contents ... 6- 30 Using RSPAN 6- 31 6- 26 Configuration 6- 34 Initial Configuration 6- 34 Management VLAN 6- 35 Network Time Protocol 6- 35 CVDM 6- 36 Configuring the VLAN Interconnect for CSM-SSLSM 6- 39 Configuration ... 1 -23 Outbound Filtering 1 -23 Additional References CHAPTER 1 -24 Enterprise Data Center Topology 2- 1 Enterprise Data Center Topology Overview 2- 1 Network Design for Multi-tier Applications 2- 3 Network...
  • 300
  • 752
  • 3
Tài liệu Cisco IT@Work Data Center Infrastructure doc

Tài liệu Cisco IT@Work Data Center Infrastructure doc

Hệ điều hành

... Presentation_ID © 20 05 Cisco Systems, Inc All rights reserved 22 Data Center Design Infrastructure is tiered by type of Data Center Production Development Development Data Center Data Center Server ... Presentation_ID © 20 05 Cisco Systems, Inc All rights reserved 45 The Tour (cont.) • Zonal power and cabling • (24 ) 62 .5 MM fiber • ( 12) or (24 ) Cat 5E • (2) 22 0v receptacles • 4-post cabinets • Networking ... Engines 2 069 x Routers 28 38 x Switches 120 x MDS 9000 Multilayer Directors 3100 x Access Points 66 ,000 x IP Telephones 47,000 x Cisco Security Agents 24 ,500 x IP Communicator / Softphones 1 46, 677...
  • 53
  • 484
  • 5
Tài liệu Data center pptx

Tài liệu Data center pptx

Quản trị mạng

... to Data Centers – Data Center Design Topology is different from Commercial Buildings – Standards body recognized this and created a Data Center specific standard, namely TIA-9 42 34 TIA-9 42 Data ... demarcation 35 TIA-9 42 Data Center Network Topology 36 TIA-9 42 Data Center Functional Areas Backbone Cabling Horizontal Cabling 37 Entrance Room • Gateway to the outside network, this is where ... important data (websites, transactions, video, voice, logs, records) – 24 x7x 365 immediate access to information from anywhere – Reliability and Redundancy 28 Trends impacting All Data Centers •...
  • 84
  • 1,690
  • 8
Tài liệu ADC KRONE - White Paper - Data Center - 3 principles of Data Center Infrastructure Design (with n pptx

Tài liệu ADC KRONE - White Paper - Data Center - 3 principles of Data Center Infrastructure Design (with n pptx

Quản trị mạng

... $1,100 Annual Downtime 28 .8 (Hours) 22 1 .6 0.4 Site Availability 99.749% 99.9 82% 99.995% 99 .67 1% Source: Uptime Institute Figure Data Center with Flexible White Space Principle 2: Reliability Uninterrupted ... the life of your data center The Three Principles of Data Center Infrastructure Design The Three Principles of Data Center Design When you understand the three principles of data center design, ... existing data center space is likely the most expensive and disruptive problem your organization can face Expanding the physical space of a data center can cost more than the original data center...
  • 8
  • 523
  • 0
Tài liệu ADC KRONE - Guide - Data Center - Quick Start GUIDE pptx

Tài liệu ADC KRONE - Guide - Data Center - Quick Start GUIDE pptx

Quản trị mạng

... Designing an Optimized Data Center – 101818AE • TIA-9 42 Data Center Standards Overview – 1 02 26 4 AE • Building for Bandwidth: How to Choose the Right Cabling Infrastructure – 1 025 77AE Web Site: www.adc.com ... foundation of data center managers’ ability to maximize their networking investments and provide a stable, efficient network architecture.” Lucinda Borovick Program director for IDC’s Datacenter Networks ... information on data center design, best practices, and standards, download the following ADC white papers at www.adc.com • The Three Principles of Data Center Infrastructure Design – 1 02 26 1 AE • Designing...
  • 4
  • 400
  • 0
Tài liệu ADC KRONE - Guide - FTTP - A Deployment guide for Network Manager docx

Tài liệu ADC KRONE - Guide - FTTP - A Deployment guide for Network Manager docx

Kỹ thuật lập trình

... technology is expected to solve this problem—transferring data at speeds from 62 2 Mbps to 2. 5 Gbps per second to users and 155 Mbps to 62 2 Mbps to the network much faster than cable modems, T1s or DSL ... Internet, data, video, and voice services to consumers and businesses Now that you’ve carefully examined the important aspects of FTTP deployment and optimization of your network, call 1- 866 -21 0-1 122 ... OLT cards in the data center Each port supports 32 homes, each OLT card supporting a total of 128 homes Each neighborhood is supported by its own FDT—up to 1,1 52 homes The first 32 subscribers in...
  • 21
  • 468
  • 0
Tài liệu Data Center High Availability Clusters Design Guide ppt

Tài liệu Data Center High Availability Clusters Design Guide ppt

Quản trị mạng

... 11 .20 .40.5 11 .20 .40.5 11 .20 .40.5 22 4.0.0. 127 22 4.0.0. 127 22 4.0.0. 127 UDP Source port: 23 UDP Source port: 23 UDP Source port: 23 Destination port: 23 Destination port: 23 Destination port: 23 ... (11 .20 .40.5), Dst Addr: 23 9 .25 5 .24 0.185 (23 9 .25 5 .24 0.185) […] Fragment offset: Time to live: Protocol: UDP (0x11) Source: 11 .20 .40.5 (11 .20 .40.5) Destination: 23 9 .25 5 .24 0.185 (23 9 .25 5 .24 0.185) The following ... 60 00 Series Switch—DC1-Left) A-19 Data Center (Catalyst 60 00 Series Switch—DC1-Right) A -20 Data Center (Catalyst 60 00 Series Switch—DC2-Left) A -20 Data Center (Catalyst 60 00 Series Switch—DC2-Right)...
  • 222
  • 638
  • 2

Xem thêm

Tìm thêm: hệ việt nam nhật bản và sức hấp dẫn của tiếng nhật tại việt nam xác định các nguyên tắc biên soạn khảo sát các chuẩn giảng dạy tiếng nhật từ góc độ lí thuyết và thực tiễn khảo sát chương trình đào tạo của các đơn vị đào tạo tại nhật bản khảo sát chương trình đào tạo gắn với các giáo trình cụ thể tiến hành xây dựng chương trình đào tạo dành cho đối tượng không chuyên ngữ tại việt nam điều tra với đối tượng sinh viên học tiếng nhật không chuyên ngữ1 khảo sát các chương trình đào tạo theo những bộ giáo trình tiêu biểu nội dung cụ thể cho từng kĩ năng ở từng cấp độ xác định mức độ đáp ứng về văn hoá và chuyên môn trong ct mở máy động cơ rôto dây quấn các đặc tính của động cơ điện không đồng bộ hệ số công suất cosp fi p2 đặc tuyến hiệu suất h fi p2 đặc tuyến dòng điện stato i1 fi p2 sự cần thiết phải đầu tư xây dựng nhà máy thông tin liên lạc và các dịch vụ từ bảng 3 1 ta thấy ngoài hai thành phần chủ yếu và chiếm tỷ lệ cao nhất là tinh bột và cacbonhydrat trong hạt gạo tẻ còn chứa đường cellulose hemicellulose chỉ tiêu chất lượng theo chất lượng phẩm chất sản phẩm khô từ gạo của bộ y tế năm 2008 chỉ tiêu chất lượng 9 tr 25