conditioning sensible cooling and sensible

Refrigeration and Air Conditioning Equipment Cooling Episode 1 docx

Refrigeration and Air Conditioning Equipment Cooling Episode 1 docx

Ngày tải lên : 12/08/2014, 16:21
... expansion (D/X), and (3) reheat We will discuss the application of these coils, their use and control, and the valves and dampers which control the flow of water and air D/X Coil In equipment cooling ... fundamentals and commercial refrigeration and air -conditioning systems This final volume deals with another phase of your career ladder-equipment cooling Since the principles of equipment cooling ... and Absorption System Centrifugal Systems and Water Treatment Centrifugal Water Pumps and Electronic Control Systems Unless otherwise stated, whenever the masculine gender is used, both men and...
  • 16
  • 272
  • 0
Refrigeration and Air Conditioning Equipment Cooling Episode 2 docx

Refrigeration and Air Conditioning Equipment Cooling Episode 2 docx

Ngày tải lên : 12/08/2014, 16:21
... Disconnect the valve and plug the tube ends Remove the screen and clean it with a recommended cleaning solvent After the screen is clean and dry, reinstall it in the valve and connect the valve ... indicated loss of capacity and the discharge valves check properly, you must remove the head and valve plate and check the valves physically 17 Disassembly, inspection, and reassembly of valve plates ... motion over the paste and glass After the valve is reconditioned, clean and reinstall it 22 Use new valve plate and cylinder head gasket when you install the valve plate and cylinder head 23 Disassembly,...
  • 16
  • 214
  • 0
Refrigeration and Air Conditioning Equipment Cooling Episode 3 pdf

Refrigeration and Air Conditioning Equipment Cooling Episode 3 pdf

Ngày tải lên : 12/08/2014, 16:21
... Check the standpipe for water seal circulation before starting the pumps (8) Start the chilled water pump and open the valves to insure circulation through the evaporator tubes and airconditioning ... of the pump seal chambers and drain the water from the lines and chambers (3) Disconnect the water seal lines between the water seal tank and the pump seal chambers and clean them by reverse ... and clean all the pipe connections (5) Clean the purge tank and flush it to remove the loosened dirt (6) Reinstall the water seal lines 25 Cleaning absorber and condenser tubes The absorber and...
  • 16
  • 316
  • 0
Refrigeration and Air Conditioning Equipment Cooling Episode 6 pps

Refrigeration and Air Conditioning Equipment Cooling Episode 6 pps

Ngày tải lên : 12/08/2014, 16:21
... process which changes calcium and magnesium compounds from soluble to insoluble forms and then removes these insolubles by sedimentation and filtration The second and most common is zeolite or ... HTH, Perchloron, and Hoodchlor It is furnished in 3- to 100-pound containers and has 65 to 70 percent of available chlorine by weight Because of its concentrated form and ease of handling, calcium ... of calcium and magnesium compounds in solution in the water Water containing 200 p.p.m hardness and a pH indication of or above will enhance the formation of scale To avoid scale in cooling towers,...
  • 16
  • 289
  • 0
Refrigeration and Air Conditioning Equipment Cooling Episode 8 doc

Refrigeration and Air Conditioning Equipment Cooling Episode 8 doc

Ngày tải lên : 12/08/2014, 16:21
... lighter, and more rugged, and operates at lower voltages than the vacuum tube Atomic Structure Essential to the understanding of semiconductor operation is the study of atomic characteristics and ... cathode, and the potential (voltage) between the cathode and the plate Refer to figure 89, a diagram of a simple diode rectifier circuit 10 When an a.c source is connected to the plate and cathode ... that the center tap current is turned to ground and then through R and inductor L to the cathode (filament) of V1 The voltage appearing across X and Y is 700 volts a.c The center tap is at zero...
  • 16
  • 324
  • 0
Refrigeration and Air Conditioning Equipment Cooling Episode 10 ppsx

Refrigeration and Air Conditioning Equipment Cooling Episode 10 ppsx

Ngày tải lên : 12/08/2014, 16:21
... of how electronics is applied to the control of airconditioning and equipment cooling systems The control Figure 135 Two-position heating and cooling system 134 as the outdoor temperature rises ... centerlines matched The top of the candle support should be inches below the bottom of the tube The candle must be made of beeswax and spermaceti, gauged to burn within 114 and 126 grains per hour The ... removal and CHAPTER The amount of cement that you would mix with 12 pounds of sand and 24 pounds of crushed rock is pounds (Sec 26, Par 1) A 1-inch space is left between the foundation and baseplate...
  • 16
  • 375
  • 0
No Holds Barred Fighting: The Ultimate Guide to Conditioning Elite Exercises and Training for NHB Competition and Total Fitness pot

No Holds Barred Fighting: The Ultimate Guide to Conditioning Elite Exercises and Training for NHB Competition and Total Fitness pot

Ngày tải lên : 05/03/2014, 21:20
... waist and touch your left toes with your right hand — Count ● Back upright and fling — Count ● Bend forward and touch the toes of the right foot with the left hand — Count ● Return to upright and ... waist and remain there throughout ● Twist and touch the toes of the left foot with the right hand — Count ● Twist and touch the toes of the right foot with the left hand — Count 45 Warm-up Fore and ... intermediate, advanced and pro.You will find a variety of routines and regimens to fit your schedule, skill level and goal set I suggest a single cover-to-cover read to grasp the principles, and then use...
  • 257
  • 634
  • 1
Báo cáo hóa học: "Nearly Monodispersion CoSm Alloy Nanoparticles Formed by an In-situ Rapid Cooling and Passivating Microfluidic Process" docx

Báo cáo hóa học: "Nearly Monodispersion CoSm Alloy Nanoparticles Formed by an In-situ Rapid Cooling and Passivating Microfluidic Process" docx

Ngày tải lên : 21/06/2014, 20:20
... Nanoscale Res Lett (2009) 4:1130–1134 1131 Flow and temperature controller P1 V1 CoCl2 and SmCl3 mixture P2 H1 H2 Inlet V2 Reducing agent and stability Inlet TC1 N2 In N2 In Y-mixer N2 Out ... process and sealed by semi-solid sealing process, is shown as the optical image in the center of the figure The reactor consists of three regions: the mixing and reaction area from the inlets of and ... inlet mixes with the reducing agent, and the metal salts are rapidly reduced to metal atoms The resulting metal atoms will nucleate and grow in the nucleation and growth area to form NPs at a constant...
  • 5
  • 316
  • 0