TrueNet ® Fiber Plug-and-Play Solutions for Data Center Applications Engineered for Uptime ™ Recognizing the need for enterprises to have a dedicated area within a building for connecting servers to internal and external networks, otherwise known as data centers, the Telecommunications Industry Association (TIA) developed and ratified the TIA-942 standard. Data centers operate at very high levels of reliability and demand design flexibility to easily accommodate frequent adds and changes to equipment. Managing the thousands of cables that typically comprise a data center should always be a high priority for the data center or network manager —particularly for maximizing system performance and uptime. ADC’s TrueNet ® Fiber plug-and-play solutions for data center applications are designed to address the reliability, scalability, and thermal needs of today’s mission-critical data centers. The product suite includes plug-and-play MPO solutions for TrueNet Fiber products for placement in the main distribution area (MDA), backbone, and horizontal and equipment distribution areas (HDA and EDA). These solutions are included in the TrueNet Zero Bit-Error Warranty, and promote increased reliability of the data center through properly managed and scalable cable density, which encourages proper airflow and reduces overall installation and maintenance costs. Fiber Plug-and-Play Solutions: Managing reliability, scalability, and thermal needs of the data center Equipment Distribution Area Horizontal Distribution Area Main Distribution Area Backbone Cabling TrueNet Fiber Panels w/MPO Cassettes Data Center Optical Distribution Frame w/MPO Solution TrueNet MPO Microcable Trunk Assemblies TracerLight ® TrueNet Fiber Panel (5RU) One of the most common questions regarding MPO deployments is how the system design addresses the polarity issue of the fiber. ADC’s TrueNet system employs the recommendations made in TIA standard TIA-568.b.1-7 TrueNet plug-and-play trunks use a key up/key down fiber array as noted in TIA-568.b.1-7. The TrueNet plug-and-play cassettes are wired straight through. In addition, TrueNet duplex jumpers have a duplex clip that is easily removed for polarity changes in the field. Polarity Made Simple TIA-568-B.1-7 4 Figure 1: Connectivity Method A for Duplex Signals NOTE 1. For ease of illustration the Type-A cable is shown with a twist. This is the same cable construction shown in Figure 6. Example Optical Path A-to-B Patch Cord Type-A Array Connector Cable A-to-A Patch Cord Figure 1 Connectivity method A for duplex signals Main Distribution Area TIA-942 presents the cross-connect architecture as the best practice for Main Distribution Area (MDA). In the past, Local Area Network (LAN) cabling was based on an interconnect architecture. While interconnects are prevalent in LANS and can work in smaller data centers, in larger data centers, an interconnect architecture limits growth and manageability by requiring routine maintenance to occur on cables directly attached to active equipment. Utilizing a centralized cross-connect frame allows maintenance to be performed without disrupting the cables attached to active equipment. All moves, adds and changes can be performed on the passive cross-connect frame. The benefits of deploying a cross-connect architecture in the MDA include: lower operating costs, enhanced reliability, and a reduced risk of downtime due to poor fiber jumper management. Data Center Optical Distribution Frame With an MPO Solution ADC’s Data Center Optical Distribution Frame (ODF) is the highest density fiber distribution frame solution available on the market. It efficiently manages up to 1,728 fiber terminations using the 144-position block (or 2,304 using the 192-position block) in a single frame in either a cross- connect or interconnect design. The data center frame’s patented design incorporates the fundamentals of cable management while using the industry’s highest fiber count MPO plug-and-play cassettes. This powerful combination provides the following benefits: • Rapidinstallationofnewdeployments • MPOtrunkscanentertherackfromunder-the-flooror overhead • Slackstorageincludedineachrackallowsfortheuseof a single jumper length • On-framejumperroutingprovidesbendradiusand physical protection for easily managing slack Horizontal and Equipment Distribution Areas Of main concern in the horizontal and equipment distribution areas is the consolidation and management of optical jumpers from Storage Area Networks (SANs), servers, switches and routers. Fiber optic panels at these consolidation points should employ ADC’s four fundamentals of fiber management: bend radius protection, cable and connector access, intuitive cable routing paths, and physical protection. TrueNet TFP Series Fiber Panels With MPO Cassettes ADC’s TrueNet Fiber Panels (TFP) combine the unique features of vertical cable guides and our patented angle- left/angle right adapters, offering bend radius protection, intuitive routing and easy connector access. Our TFP series can be ordered in one, two, or five rack-unit sizes to fit your unique needs. Designed for rack or cabinet mounting in the horizontal or equipment distribution area, the TFP’s modularity, functionality and density make them ideal for mounting in close proximity to servers, switches, routers and SANs. The TFP’s functionality can be extended with our plug- and-play angled cassettes, which add up to 24 fiber terminations each for jumper management in SANs-rich environments. These cassettes snap into place effortlessly; and even come from the factory prelabeled with simple installation instructions. Angled Left and Right Cassettes up to 24 fiber • terminations Vertical cable guides can be quickly installed when • additional jumper routing and physical protection is required Sliding tray and removable covers ease deployment and • troubleshooting Backbone Cabling In order to maintain the optimum performance of servers and switches, the TIA standard recommends incorporating hot aisle/cool aisle into the data center architecture. In a raised floor environment it is important to maintain proper airflow to promote the optimal cooling of active electronics. Ideal airflow requires proper design to prevent unintended air dams that will reduce data center reliability and efficiency. Moving the fiber optic cabling overhead frees up space in the raised floor to promote proper airflow. Additional benefits to overhead cabling and raceway include: • Easieraccesstojumpersandcableformaintenance • Logicalseparationoffiberfromcoppercables • Reliableadditionandupgradeofnewequipment TrueNet MPO Microcable Trunk Assemblies ADC’s TrueNet Plug-and-Play microcable trunk assemblies are round 12 fiber optical trunk cables pre-terminated with a high-density MPO connector on both ends. They can be used in conjunction with any of the other plug-and-play connectivity products to rapidly deploy fiber into a data center. The TrueNet Microcable assemblies can simply be connected to any plug-and-play cassette in the optical distribution frame or fiber enclosure which eliminates the need for on-site fiber termination and preparation. The TrueNet Plug-and-Play trunk consists of a round Kevlar reinforced cable with integrated MPO strain relief and optional pulling eye. Its total outer diameter is 5.5mm. The round design also: • Ismoremanageablethanthetraditionalribbonplug- and-play trunk • Eliminatespreferentialbendissues,whichresultsin increased density • CreatescompatibilitywithADC’sFiberGuideOptical Raceway system for the ultimate in protection and flexibility TrueNet FiberGuide ® Optical Raceway System ADC’sFiberGuidesystemfeaturesavarietyofproducts that allow for quick and easy installation. Express Exit ™ , for example, enables new drops to be added or removed quickly and easily. Our tool-less Snap-Fit ™ junctions save time and money with quick install snap-on covers and hinged- covers.TheFiberGuideracewaysystemfeatures38support structures, over 75 fittings and multiple drop options. ADC’sFiberGuidesystemalsoincludesahorizontal storage straight section to manage fiber cables or jumpers overhead, reducing the need to store it in the raised floor, and helping to increase airflow. The 4"x12" horizontal storage straight section also: Accommodates up to 12 feet of Plug-and-Play • Microcable Trunk slack Installs with tool-less components for quick and efficient • reconfigurations Provides easier access to jumpers and trunk cables for • maintenance TrueNet TracerLight ® ADC’s innovative TracerLight jumper dramatically reduces system turn-up speed and improves accuracy. TracerLight offers you a quick and accurate method of identifying the termination point of optical patch cords, thus minimizing the risk of taking the wrong fiber out of service. With TracerLight you’ll experience a 72% reduction in jumper turn-up times and 13% reduction in accidental down-time! Description Catalog Number Blocks loaded with plug-and-play cassettes; black 144-position block; MPO – LC (aqua) multimode adapters; 50/125 multimode fiber laser optimized to 300 meters Left block orientation NGFB-MPML0C112 Right block orientation NGFB-MPMR0C112 144-position block; MPO-LC singlemode adapters; Zero water peak singlemode fiber Left block orientation NGFB-MPML0K412 Right block orientation NGFB-MPMR0K412 Rack 30" x 24" x 7 ft frame; black NGFB-MDF7A100-30 Ordering Information Data Center Optical Distribution Frame (ODF) Description Catalog Number Termination only rack or cabinet mount panel, black 1 RU empty panel, black; accommodates 2 modular adapter packs; T-handle latch close TFP-1TT00-000B 2 RU empty panel, black; accommodates 4 modular adapter packs; T-handle latch close TFP-2TT00-000B 5 RU empty panel, black: accommodates 12 modular adapter packs; T-handle latch close TFP-5TT00-000B Plug-and-Play Cassettes 12 fiber cassettes; 6 LC (aqua) multimode adapters; 50/125 multimode fiber laser optimized to 300 meters Angle left TFP-12MPLDQ2 Angle right TFP-12MPRDQ2 24 fiber cassettes; 12 LC (aqua) multimode adapters; 50/125 multimode fiber laser optimized to 300 meters Angle left TFP-24MPLDQ2 Angle right TFP-24MPRDQ2 12 fiber cassettes; 6 LC singlemode adapters; singlemode fiber Angle left TFP-12MPLSQ5 Angle right TFP-12MPRSQ5 24 fiber cassettes; 12 LC singlemode adapters; singlemode fiber Angle left TFP-24MPLSQ5 Angle right TFP-24MPRSQ5 Ordering Information TFP Series Fiber Panel Description Catalog Number 1 MPO-MPO trunk, 12 fiber microcable, 50/125 multimode laser optimized to 300 meters, plenum jacket with pulling eye sock MRM-AF/AFEGXXXF MPO-MPO trunk, 12 fiber microcable, singlemode reduced water peak fiber, plenum jacket with pulling eye sock MRS-AF/AFEAXXXF 1 XXX = length in feet (standard lengths) 100 = 100 ft, 125 = 125 ft, 150 = 150 ft. For additional custom lengths, please contact ADC. Ordering Information Plug-and-Play Microcable Trunk Assemblies Description Catalog Number Horizontal storage components 4x12 slack storage straight section; yellow FGS-MSHS-STOR-F Snap-fit junction; yellow FGS-MFAW-F T-section; yellow FGS-MHRT-F ForbillofmaterialsforacompleteFiberGuideinstallation,pleasecontactADC. Ordering Information 12"FiberGuideOpticalRacewaySystem Description Catalog Number 1 50/125 multimode fiber laser optimized to 300 meters LC-LC duplex patch cord FTL-PPKXXXM LC-SC duplex patch cord FTL-9PKXXXM Singlemode fiber LC-LC duplex patch cord FTL-CCZXXXM LC-SC duplex patch cord FTL-7CZXXXM TracerLight Power source FTL-PS 1 XXX = Length in meters. Standard lengths: 001 = 1 meter, 002 = 2 meters, 003 = 3 meters, 005 = 5 meters, 006 = 6 meters, 010 = 10 meters, 015 = 15 meters. Ordering Information TracerLight Patch Cords FIBER PLUG-AND-PLAY SOLUTIONS FOR DATA CENTER APPLICATIONS Website: www.adc.com FromNorthAmerica,CallTollFree:1-800-366-3891•OutsideofNorthAmerica:+1-952-938-8080 Fax:+1-952-917-3237•ForalistingofADC’sglobalsalesofficelocations,pleaserefertoourwebsite. ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, Minnesota USA 55440-1101 Specifications published here are current as of the date of publication of this document. Because we are continuously improving our products, ADC reserves the right to change specifications without prior notice. At any time, you may verify product specifications by contacting our headquarters office in Minneapolis. ADC Telecommunications, Inc. views its patent portfolio as an important corporate asset and vigorously enforces its patents. Products or features contained herein may be covered by one or more U.S. or foreign patents. An Equal Opportunity Employer 103383AE 3/08 Revision © 2008, 2007, 2006 ADC Telecommunications, Inc. All Rights Reserved . TrueNet ® Fiber Plug-and-Play Solutions for Data Center Applications Engineered for Uptime ™ Recognizing the need for enterprises to have. meters, 015 = 15 meters. Ordering Information TracerLight Patch Cords FIBER PLUG-AND-PLAY SOLUTIONS FOR DATA CENTER APPLICATIONS Website: www.adc.com FromNorthAmerica,CallTollFree:1-800-366-3891•OutsideofNorthAmerica:+1-952-938-8080 Fax:+1-952-917-3237• For alistingofADC’sglobalsalesofficelocations,pleaserefertoourwebsite. ADC

Ngày đăng: 17/01/2014, 12:20

Từ khóa liên quan

Tài liệu cùng người dùng

Tài liệu liên quan