Thông tin tài liệu
S
ONEPLEX
®
E1 L
OOP
E
XTENDER
E
XCHANGE
P
LATFORM
The Soneplex System
from ADC. The T1/E1
Service Delivery Experts
The Soneplex E1 Loop Extender Exchange platform
provides centralized network management and point to
multi-point transport for up to 20 E1 and 40 Nx64 kbps
circuits over the local loop. Suitable for indoor or
outside plant deployment, it provides maximum
operational flexibility while minimizing network
elements and installation time.
ADC's Soneplex E1 system is the lowest total cost solution
for carriers to grow their E1-based business services. The
Soneplex system lowers the cost of E1-based services over
copper or fiber using HDSL or optical E2 technology, in a
single platform. From operations, maintenance and
provisioning, to central office space and cabling, the
Soneplex system is designed to take costs out of today's
E1 delivery approach, adding profit to your bottom line.
Features
• High-density front access ETSI-compliant chassis supports up to
20 E1 G.703/G.704 circuits over optical fiber local loops
• High-density rear access ANSI-compliant chassis supports up to
20 E1 G.703/G.704 circuits over optical fiber local loops
• Front and Rear Access chassis support of up to 40 Nx64 kbps E1
HDSL circuits, each over one copper pair
• Centralized SNMP-based network management for circuit
provisioning, real-time performance monitoring and alarm collection
• Dual power feed system ensures maximum circuit availability
21/99
455
Soneplex
®
E1 Loop Extender Exchange Platform
Description
System
Components
Front Access Loop
Extender Chassis
The Soneplex E1 Loop Extender Exchange Platform consists of the Exchange chassis,
common control, and software portions of the Soneplex E1 Loop Extender System. This
system delivers optical and copper transport of voice, data, and video services. The
platform features centralized SNMP-based network management, providing end-to-end
visibility of all circuits. The management system is interfaced from a local menu-driven
craft access port, remote dial-up modem, Telnet or a portable graphical user interface
(GUI) element manager. Local and remote provisioning lowers installation cost by
enabling one technician to turn-up individual circuits. Real-time non-service affecting
performance monitoring ensures high quality service deployment by alerting operators
to intermittent and marginal service events before adverse impact. System
sectionalization isolates the circuit fault so field technicians are dispatched to the right
location the first time. The dual power feed system eliminates service impact during
power failures at the equipment deployment facility.
Designed to meet ETSI standards, the Soneplex E1 Front Access Loop Extender chassis
provides 22 modular slots. Twenty slots are used for service delivery modules and two
slots are used for common control. Any combination of HDSL and E1 quad optical fiber
modules provide transport for up to 20 E1 circuits from one chassis. The Shelf Controller
Unit (SCU) and optional E1 Alarm Processor Unit (EAPU) are used in the common
control slots. Three front access chassis versions are available for flexible E1 network
interface: 120 ohm balanced with wire-wrap connectors, 120 ohm balanced with DB9
connectors, or 75 ohm unbalanced with BNC connectors.
Specifications
Dimensions (HxWxD):
Weight:
Operating Temperature:
Operating Humidity:
Operating Power:
E1 Interface Options:
HDSL Interface:
System Configuration:
Regulatory Compliance
Climatic:
EMC:
Safety:
Mechanical:
35.5cm x 43.2cm x 28cm (14" x 17" x 11")
9.09 kg (20 lbs)
-40°C to 65°C (-40°F to 14°F)
5% to 95%, non-condensing
-48 VDC nominal input; (-40 to -72 VDC operating range)
Redundant A and B supply inputs
120 Ω balanced wire-wrap
120 Ω balanced DB9
75 Ω unbalanced BNC
135 Ω DB9 or 135 Ω wire-wrap
20 slots for local loop delivery modules
Two slots for common control modules
EN 300 019
EN 55022, EN 61000, FCC part 15 class A
EN 60950, UL 1950
ETSI 300 119, TR-1089
31/99
455
Soneplex
®
E1 Loop Extender Exchange Platform
Soneplex E1
Rear Access Loop
Extender Chassis
The Soneplex E1 Rear Access Loop Extender chassis provides 22 modular slots and is
designed to meet standard installations using little vertical rack space and where access to
the back of the chassis is available. Twenty slots are used for service delivery modules and
two slots are used for common control. Any combination of HDSL and E1 quad optical
fiber modules provide transport for up to 20 E1 circuits from one chassis. The Shelf
Controller Unit (SCU) and optional E1 Alarm Processor Unit (EAPU) are used in the
common control slots. The rear access chassis is designed with balanced 120 ohm wire-
wrap connectors for E1 network interface.
E1 Alarm
Processor Unit
The optional E1 Alarm Processor Unit (EAPU) provides system alarm reporting, along
with support for up to eight housekeeping alarm inputs. Critical, major, and minor
alarms are reported via front-panel LEDs. The alarm cutoff option is accessed from a
front faceplate switch or management port.
Specifications
Dimensions (HxWxD):
Weight:
Operating Temperature:
Operating Humidity:
Operating Power:
E1 Interface:
HDSL Interface:
System Configuration:
Regulatory Compliance
EMC:
Safety:
Mechanical:
15.2cm x 43.2cm x 28cm (6" x 17" x 11")
7.27 kg (16 lbs)
-40°C to 65°C (-40°F to 149°F)
5% to 95%, non-condensing
-48 VDC nominal input; (-40 to -72 VDC operating range)
Redundant A and B supply inputs
120 Ω balanced wire-wrap
135 Ω wire-wrap
20 slots for local loop delivery modules
Two slots for common control modules
FCC part 15 class A
UL 1459
TR-1089
Specifications
Dimensions (HxWxD):
Weight:
Power Consumption:
Alarm Outputs:
Alarm Inputs:
12.4 x 1.75 x 24.8 cm (4.9" x .7" x 9.75")
.25 kg (.56 lb)
7.5 watts maximum
Relay contact outputs for Visual and Audible Major, Minor, and
Critical alarms
Eight contact closure inputs for housekeeping alarms
41/99
455
Soneplex
®
E1 Loop Extender Exchange Platform
The Soneplex Shelf Controller Unit (SCU) provides centralized element manage-
ment to the Soneplex system for configuration, operation and maintenance.
Access is available through any of four access ports, including front panel craft,
two serial and one Ethernet.
SNMP, point-to-point protocol (PPP) and ASCII management commands and
responses are all available on the SCU. The front panel craft provides easy access
for local technical support during installation and test using ASCII commands.
Network operations control (NOC) access is provided through an IEEE 802.3
Ethernet port and two serial ports. The SCU Ethernet port allows SNMP LAN
connectivity to the NOC. The two serial ports support ASCII and PPP. The serial
ports allow modem connectivity for remote access between NOC and Soneplex.
PPP enables Telnet access to the craft screens. Up to eight simultaneous Telnet
sessions can be established through the PPP serial port and Ethernet port.
Shelf Controller
Unit
Specifications
Dimensions (HxWxD):
Weight:
Power Consumption:
Management Interfaces
Front Panel Craft Port:
Remote Craft Access Port:
SNMP Access Port:
12.38 x 1.75 x 24.76 cm (4.9" x .7" x 9.75")
.25 kg (.56 lb)
5.0 watts maximum
RS232C / DB25; ASCII to VT100 terminal
RS232C / DB25; ASCII or PPP
Ethernet / RJ45 or wire-wrap; SNMP
51/99
455
Soneplex
®
E1 Loop Extender Exchange Platform
Ordering
Information
Soneplex E1 Loop Extender Chassis Front Access
with 120 ohm DB9 E1 and 135 ohm DB9 HDSL
with 75 ohm BNC E1 and 135 ohm DB9 HDSL
with 120 ohm wire-wrap E1 and 135 wire-wrap HDSL
Soneplex E1 Loop Extender Chassis 19-inch Rear Access
with 120 ohm wire-wrap E1 and 135 ohm wire-wrap
Soneplex E1 Alarm Processor Unit
Soneplex E1 Shelf Controller Unit
Soneplex SCU Element Management System Software
Heat Baffle/Cable Management Panel 19-inch rack mount
Description Catalog Number
ELX-EFRMDD0A0
ELX-EFRMBD0A0
ELX-EFRMWW0A0
SPX-FRM2A1
ELX-APU0B1
SPX-SCU0A1
SPX-SCUEMS0A1
SPX-BAFF2A1
SNMP Graphical
User Interface
(GUI) Software
The Soneplex SNMP GUI software provides a graphical user interface for the
Soneplex element manager. Soneplex GUI software operates on Windows NT
™
or
SUN Solaris
™
based systems. The Soneplex GUI can be used as a stand-alone
applications or integrated with HP OpenView Network Node Manager software.
The Soneplex SNMP GUI reduces staff training and maintenance costs by
providing configuration, maintenance and test capabilities through an easy to
use point and click graphical interface.
Specifications
PC:
SUN UNIX:
Windows NT
™
Minimum release 4.0
Pentium 100 MHz processor
64 MB of RAM
HP OpenView Network Node Manager for PC Windows NT
™
Minimum release 5.2
Soneplex SCU Element Manager System software
SUN Solaris
™
Minimum release 2.51
SPARC 5 workstation
128 MB RAM
HP Open View Network Node Manager for SUN Solaris
Minimum release 5.01
Soneplex SCU Element Manager System software
455 1/99 Revision © 1998, 1999 ADC Telecommunications, Inc. All Rights Reserved An Equal Opportunity Employer
Specifications published here are current as of the date of publication of this document. Because we are continuously improving our products,
ADC reserves the right to change specifications without prior notice. At any time, you may verify product specifications by contacting our
headquarters office in Minneapolis. ADC Telecommunications, Inc. views its patent portfolio as an important corporate asset and vigorously
enforces its patents. Products or features contained herein may be covered by one or more U.S. or foreign patents.
ADC Telecommunications, Inc.
P.O. Box 1101
Minneapolis, Minnesota 55440-1101
Fax: (612) 946-3237
From North America, Call Toll Free: 1-800-366-3891, Ext. 3223
Outside of North America: 612-938-8080
Home Page Address: http://www.adc.com
International Sales Offices:
Brussels, Belgium 32-2-712-6500 • United Kingdom 44-1189 879200 • Dusseldorf, Germany 49-211-530-655-0
Madrid, Spain 34-1-361-01-68 • Sydney, Australia 61-2-9975-1499 • Singapore 65-225-8228 • Beijing, China 86-
10-6500-7001 • Seoul, Korea 82-2-333-8989 • Bangalore, India 91-80-671-0230 • Malaysia 603-254-0025
Bangkok, Thailand 66-2-9595199 • Philippines 632-892-4476 • Sao Paulo, Brazil 55-11-3040-0666 • Buenos Aires,
Argentina 541-788-8700 • Mexico City, Mexico 525-658-4519 • Venezuela 58-2-286-1444 • Miami Lakes, FL
(Caribbean/Miami) 305-231-8742 • Montreal, Quebec (514) 677-9166 Vancouver, BC (604) 270-1675
Toronto, Ont. (905) 629-3104 • Ottawa, Ont. (613) 599-5729
. TR-1089
31/99
455
Soneplex
®
E1 Loop Extender Exchange Platform
Soneplex E1
Rear Access Loop
Extender Chassis
The Soneplex E1 Rear Access Loop Extender chassis. availability
21/99
455
Soneplex
®
E1 Loop Extender Exchange Platform
Description
System
Components
Front Access Loop
Extender Chassis
The Soneplex E1 Loop Extender Exchange