Tài liệu SONEPLEX E1 LOOP EXTENDER EXCHANGE PLATFORM ppt

6 306 0
Tài liệu SONEPLEX E1 LOOP EXTENDER EXCHANGE PLATFORM ppt

Đang tải... (xem toàn văn)

Thông tin tài liệu

S ONEPLEX ® E1 L OOP E XTENDER E XCHANGE P LATFORM The Soneplex System from ADC. The T1/E1 Service Delivery Experts The Soneplex E1 Loop Extender Exchange platform provides centralized network management and point to multi-point transport for up to 20 E1 and 40 Nx64 kbps circuits over the local loop. Suitable for indoor or outside plant deployment, it provides maximum operational flexibility while minimizing network elements and installation time. ADC's Soneplex E1 system is the lowest total cost solution for carriers to grow their E1-based business services. The Soneplex system lowers the cost of E1-based services over copper or fiber using HDSL or optical E2 technology, in a single platform. From operations, maintenance and provisioning, to central office space and cabling, the Soneplex system is designed to take costs out of today's E1 delivery approach, adding profit to your bottom line. Features • High-density front access ETSI-compliant chassis supports up to 20 E1 G.703/G.704 circuits over optical fiber local loops • High-density rear access ANSI-compliant chassis supports up to 20 E1 G.703/G.704 circuits over optical fiber local loops • Front and Rear Access chassis support of up to 40 Nx64 kbps E1 HDSL circuits, each over one copper pair • Centralized SNMP-based network management for circuit provisioning, real-time performance monitoring and alarm collection • Dual power feed system ensures maximum circuit availability 21/99 455 Soneplex ® E1 Loop Extender Exchange Platform Description System Components Front Access Loop Extender Chassis The Soneplex E1 Loop Extender Exchange Platform consists of the Exchange chassis, common control, and software portions of the Soneplex E1 Loop Extender System. This system delivers optical and copper transport of voice, data, and video services. The platform features centralized SNMP-based network management, providing end-to-end visibility of all circuits. The management system is interfaced from a local menu-driven craft access port, remote dial-up modem, Telnet or a portable graphical user interface (GUI) element manager. Local and remote provisioning lowers installation cost by enabling one technician to turn-up individual circuits. Real-time non-service affecting performance monitoring ensures high quality service deployment by alerting operators to intermittent and marginal service events before adverse impact. System sectionalization isolates the circuit fault so field technicians are dispatched to the right location the first time. The dual power feed system eliminates service impact during power failures at the equipment deployment facility. Designed to meet ETSI standards, the Soneplex E1 Front Access Loop Extender chassis provides 22 modular slots. Twenty slots are used for service delivery modules and two slots are used for common control. Any combination of HDSL and E1 quad optical fiber modules provide transport for up to 20 E1 circuits from one chassis. The Shelf Controller Unit (SCU) and optional E1 Alarm Processor Unit (EAPU) are used in the common control slots. Three front access chassis versions are available for flexible E1 network interface: 120 ohm balanced with wire-wrap connectors, 120 ohm balanced with DB9 connectors, or 75 ohm unbalanced with BNC connectors. Specifications Dimensions (HxWxD): Weight: Operating Temperature: Operating Humidity: Operating Power: E1 Interface Options: HDSL Interface: System Configuration: Regulatory Compliance Climatic: EMC: Safety: Mechanical: 35.5cm x 43.2cm x 28cm (14" x 17" x 11") 9.09 kg (20 lbs) -40°C to 65°C (-40°F to 14°F) 5% to 95%, non-condensing -48 VDC nominal input; (-40 to -72 VDC operating range) Redundant A and B supply inputs 120 Ω balanced wire-wrap 120 Ω balanced DB9 75 Ω unbalanced BNC 135 Ω DB9 or 135 Ω wire-wrap 20 slots for local loop delivery modules Two slots for common control modules EN 300 019 EN 55022, EN 61000, FCC part 15 class A EN 60950, UL 1950 ETSI 300 119, TR-1089 31/99 455 Soneplex ® E1 Loop Extender Exchange Platform Soneplex E1 Rear Access Loop Extender Chassis The Soneplex E1 Rear Access Loop Extender chassis provides 22 modular slots and is designed to meet standard installations using little vertical rack space and where access to the back of the chassis is available. Twenty slots are used for service delivery modules and two slots are used for common control. Any combination of HDSL and E1 quad optical fiber modules provide transport for up to 20 E1 circuits from one chassis. The Shelf Controller Unit (SCU) and optional E1 Alarm Processor Unit (EAPU) are used in the common control slots. The rear access chassis is designed with balanced 120 ohm wire- wrap connectors for E1 network interface. E1 Alarm Processor Unit The optional E1 Alarm Processor Unit (EAPU) provides system alarm reporting, along with support for up to eight housekeeping alarm inputs. Critical, major, and minor alarms are reported via front-panel LEDs. The alarm cutoff option is accessed from a front faceplate switch or management port. Specifications Dimensions (HxWxD): Weight: Operating Temperature: Operating Humidity: Operating Power: E1 Interface: HDSL Interface: System Configuration: Regulatory Compliance EMC: Safety: Mechanical: 15.2cm x 43.2cm x 28cm (6" x 17" x 11") 7.27 kg (16 lbs) -40°C to 65°C (-40°F to 149°F) 5% to 95%, non-condensing -48 VDC nominal input; (-40 to -72 VDC operating range) Redundant A and B supply inputs 120 Ω balanced wire-wrap 135 Ω wire-wrap 20 slots for local loop delivery modules Two slots for common control modules FCC part 15 class A UL 1459 TR-1089 Specifications Dimensions (HxWxD): Weight: Power Consumption: Alarm Outputs: Alarm Inputs: 12.4 x 1.75 x 24.8 cm (4.9" x .7" x 9.75") .25 kg (.56 lb) 7.5 watts maximum Relay contact outputs for Visual and Audible Major, Minor, and Critical alarms Eight contact closure inputs for housekeeping alarms 41/99 455 Soneplex ® E1 Loop Extender Exchange Platform The Soneplex Shelf Controller Unit (SCU) provides centralized element manage- ment to the Soneplex system for configuration, operation and maintenance. Access is available through any of four access ports, including front panel craft, two serial and one Ethernet. SNMP, point-to-point protocol (PPP) and ASCII management commands and responses are all available on the SCU. The front panel craft provides easy access for local technical support during installation and test using ASCII commands. Network operations control (NOC) access is provided through an IEEE 802.3 Ethernet port and two serial ports. The SCU Ethernet port allows SNMP LAN connectivity to the NOC. The two serial ports support ASCII and PPP. The serial ports allow modem connectivity for remote access between NOC and Soneplex. PPP enables Telnet access to the craft screens. Up to eight simultaneous Telnet sessions can be established through the PPP serial port and Ethernet port. Shelf Controller Unit Specifications Dimensions (HxWxD): Weight: Power Consumption: Management Interfaces Front Panel Craft Port: Remote Craft Access Port: SNMP Access Port: 12.38 x 1.75 x 24.76 cm (4.9" x .7" x 9.75") .25 kg (.56 lb) 5.0 watts maximum RS232C / DB25; ASCII to VT100 terminal RS232C / DB25; ASCII or PPP Ethernet / RJ45 or wire-wrap; SNMP 51/99 455 Soneplex ® E1 Loop Extender Exchange Platform Ordering Information Soneplex E1 Loop Extender Chassis Front Access with 120 ohm DB9 E1 and 135 ohm DB9 HDSL with 75 ohm BNC E1 and 135 ohm DB9 HDSL with 120 ohm wire-wrap E1 and 135 wire-wrap HDSL Soneplex E1 Loop Extender Chassis 19-inch Rear Access with 120 ohm wire-wrap E1 and 135 ohm wire-wrap Soneplex E1 Alarm Processor Unit Soneplex E1 Shelf Controller Unit Soneplex SCU Element Management System Software Heat Baffle/Cable Management Panel 19-inch rack mount Description Catalog Number ELX-EFRMDD0A0 ELX-EFRMBD0A0 ELX-EFRMWW0A0 SPX-FRM2A1 ELX-APU0B1 SPX-SCU0A1 SPX-SCUEMS0A1 SPX-BAFF2A1 SNMP Graphical User Interface (GUI) Software The Soneplex SNMP GUI software provides a graphical user interface for the Soneplex element manager. Soneplex GUI software operates on Windows NT ™ or SUN Solaris ™ based systems. The Soneplex GUI can be used as a stand-alone applications or integrated with HP OpenView Network Node Manager software. The Soneplex SNMP GUI reduces staff training and maintenance costs by providing configuration, maintenance and test capabilities through an easy to use point and click graphical interface. Specifications PC: SUN UNIX: Windows NT ™ Minimum release 4.0 Pentium 100 MHz processor 64 MB of RAM HP OpenView Network Node Manager for PC Windows NT ™ Minimum release 5.2 Soneplex SCU Element Manager System software SUN Solaris ™ Minimum release 2.51 SPARC 5 workstation 128 MB RAM HP Open View Network Node Manager for SUN Solaris Minimum release 5.01 Soneplex SCU Element Manager System software 455 1/99 Revision © 1998, 1999 ADC Telecommunications, Inc. All Rights Reserved An Equal Opportunity Employer Specifications published here are current as of the date of publication of this document. Because we are continuously improving our products, ADC reserves the right to change specifications without prior notice. At any time, you may verify product specifications by contacting our headquarters office in Minneapolis. ADC Telecommunications, Inc. views its patent portfolio as an important corporate asset and vigorously enforces its patents. Products or features contained herein may be covered by one or more U.S. or foreign patents. ADC Telecommunications, Inc. P.O. Box 1101 Minneapolis, Minnesota 55440-1101 Fax: (612) 946-3237 From North America, Call Toll Free: 1-800-366-3891, Ext. 3223 Outside of North America: 612-938-8080 Home Page Address: http://www.adc.com International Sales Offices: Brussels, Belgium 32-2-712-6500 • United Kingdom 44-1189 879200 • Dusseldorf, Germany 49-211-530-655-0 Madrid, Spain 34-1-361-01-68 • Sydney, Australia 61-2-9975-1499 • Singapore 65-225-8228 • Beijing, China 86- 10-6500-7001 • Seoul, Korea 82-2-333-8989 • Bangalore, India 91-80-671-0230 • Malaysia 603-254-0025 Bangkok, Thailand 66-2-9595199 • Philippines 632-892-4476 • Sao Paulo, Brazil 55-11-3040-0666 • Buenos Aires, Argentina 541-788-8700 • Mexico City, Mexico 525-658-4519 • Venezuela 58-2-286-1444 • Miami Lakes, FL (Caribbean/Miami) 305-231-8742 • Montreal, Quebec (514) 677-9166 Vancouver, BC (604) 270-1675 Toronto, Ont. (905) 629-3104 • Ottawa, Ont. (613) 599-5729 . TR-1089 31/99 455 Soneplex ® E1 Loop Extender Exchange Platform Soneplex E1 Rear Access Loop Extender Chassis The Soneplex E1 Rear Access Loop Extender chassis. availability 21/99 455 Soneplex ® E1 Loop Extender Exchange Platform Description System Components Front Access Loop Extender Chassis The Soneplex E1 Loop Extender Exchange

Ngày đăng: 17/01/2014, 08:20

Từ khóa liên quan

Tài liệu cùng người dùng

  • Đang cập nhật ...

Tài liệu liên quan