Tài liệu Engineered Kitchen Ventilation Systems. pdf

64 309 1
Tài liệu Engineered Kitchen Ventilation Systems. pdf

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

Thông tin tài liệu

April 2008 All the products you need for Engineered Kitchen Ventilation Systems. Make-Up Air & Packaged Rooftops Accurex specializes in ventilation comfort—for restaurants and other food service establishments. Our many top performing kitchen ventilation products reflect the industry’s latest technological advances and will provide you with a fully integrated ventilation system that results in a positive, balanced building where customers and employees prefer to dine and work. Our state-of-the-art, computer-aided product selection program (CAPS) helps you select and configure products for your system, view real-time drawings and create AutoCAD files quickly. You’ll also like the friendly, responsive customer service we provide. Your Accurex representative is just a phone call or e-mail away, and is always well prepared to help you design a ventilation system that reduces future energy and operating costs. We listen to you, our customer, when designing our diverse product line. Accurex believes in continuous improvement. Our engineers are constantly developing and redesigning products, responding to the needs of our customers. Extensive prototype modeling and testing, results in products that have higher efficiencies with lower installation and operating costs. Accurex engineers are focused on delivering reliable and convenient products that result in a positive ventilation experience. Reliability and top performance are ensured through extensive testing. Accurex products are comprehensively tested for structural integrity, aerodynamic performance, sound levels, mechanical operation, vibration, temperatures, environmental impact and more. Fans are tested in two on-site air chambers and a sound testing facility. Accurex products carry several certifications including AMCA, UL, and ETL. A single source for all your kitchen ventilation needs. Whether it’s a large project or a small one, Accurex will build and deliver your entire kitchen system quickly and efficiently. Our products range from kitchen hoods, exhaust fans, dedicated make-up air, packaged rooftops, controls, variable volume systems, fire suppression, utility distribution and more. [ 2 ] Comfortable energy efficient kitchen ventilation starts here. [ 3 ] Selection Chart Table of Contents Model Heating Type Cooling Type Maximum Performance Pages XKFSB Untempered Untempered 9,800 cfm 2 in. wg Features 4-8 Performance 48-51 XKFSD Untempered Untempered 2,300 cfm 1 in. wg Features 4-8 Performance 48-51 XDGK Direct Gas-Fired Untempered 8,500 cfm 800,000 BTU/hr Features 10-21 Performance 52 XDG Direct Gas-Fired Evaporative 15,000 cfm 1,600,000 BTU/hr Features 10-21 Performance 53-54 XDGX Direct Gas-Fired Evaporative 15,000 cfm 2,000,000 BTU/hr Features 10-21 Chilled Water Performance 54-55 Direct Expansion (DX) XIG Indirect Gas-Fired Evaporative 7,000 cfm 400,000 BTU/hr Features 22-31 Performance 56-57 XIGX Indirect Gas-Fired Evaporative 15,000 cfm 1,200,000 BTU/hr Features 22-31 Chilled Water Performance 58-59 Direct Expansion (DX) XMSX Electric Evaporative 15,000 cfm 220 kW Features 32-37 Hot Water Chilled Water Steam Performance 60-61 Direct Expansion (DX) Untempered XVPR Indirect Gas-Fired Direct Expansion (DX) 12,000 cfm 44 kW Features 38-41 Performance 62 Roof Curbs NA NA NA NA Features 42-44 Performance NA [ 4 ] Untempered Make-Up Air Units XKSFB and XKSFD models are UL Listed for electrical (UL US 705) File no. E40001. * UL is optional and must be specified. XKSFD and XKSFB models are ETL Listed. [ 5 ] XKSFD - 70 - H05 Model XKSFB - Belt Drive XKSFD - Direct Drive Model Number Code Blower Size 70 — 118 Housing Size 05 — 25 The Model Number Code is designed to completely identify the unit. The correct code letters must be specified to designate belt or direct drive, configurations and size. Untempered Model Overview Accurex’s untempered make-up air units are specifically designed to provide industry leading performance and durability for restaurant and other food service applications. Untempered make-up air units are available in belt drive (XKSFB) and direct drive (XKSFD) arrangements, for maximum performance and flexibility. Eight available blower sizes provide airflow capacities up to 9,800 cfm (16,650 m ³ /hr) and static pressure capabilities up to 2.0 in. wg (497 Pa). Accurex untempered make-up air units incorporate an industry first hinged design. The hinged design minimizes installation time, while maximizes access to fan and motor assemblies. Accurex’s untempered make-up air units feature: • XKSFB and XKSFD sizes are certified to UL 705 • All blower sizes are tested in our accredited laboratory to ensure accurate fan performance • Casing is constructed of G90 galvanized steel [ 6 ] Lifting Lugs – Located on the base rail for ease of rigging and installation. Nema-3R Disconnect – Factory mounted and wired to the motor. All wiring and electrical components comply with the National Electric Codes (NEC) and are either UL/C-UL US Listed or Recognized. G90 Galvanized Construction – Provides superior corrosion resistance and insures the appearance is maintained for the life of the unit. UL Class 2 Washable Filters – Effortlessly removable and cleanable one-inch aluminum mesh filters are sized such that air velocities do not exceed 900 fpm. Vibration Isolators – True vibration isolators contain two independent studs with rubber neoprene to support the drive assembly and blower, for long life and quiet operation. Hinged Access Door – Allows straightforward access to motor, drives and blowers for maintenance. UL 705 Product Certification – Assures the safety of electrical components and connections within power ventilators. Blower Assemblies – Double-width, double inlet forward-curved fans are statically and dynamically balanced. Ground and polished shafts mounted in permanently lubricated ball bearings, with a minimum L(10) life in excess of 100,000 hours, provide unparalleled quality and reliability. Motor – Energy efficient motors, complying with EPACT standards for single speed ODP and TEFC enclosures are carefully matched to the fan load. Single-phase motors provided with the XKSFB and XKSFD are thermally protected at 2 hp and less. Drive Assembly – Drives are sized for a minimum of 150% of the driven horsepower. Machined cast pulleys are adjustable for final system balancing. Belts are static-free and oil-resistant. XKSFB / XKSFD Model XKSFB (belt drive) and XKSFD (direct drive) supplies untempered make-up air where needed. Choose from a downturned or extended weatherhood. Both are designed to provide compliance to NFPA 96 when used with a combination package. Horizontal and downblast discharge arrangements are available. Airflow ranges from 800 to 9,800 cfm (1,359 to 16,650 m ³ /hr). Standard Construction Features Untempered Model Comparison XKSFB. XKSFD. [ 7 ] Speed Controller – Available on the XKSFD, the speed controller provides an economical means of system balancing. Special Coatings – Permatector ™ coating is available for a durable, long lasting finish. Decorative coatings are also available in a variety of colors to match existing building fixtures. Consult your Accurex representative for coating selections. Discharge Blower Arrangements – Multiple discharge arrangements are available to meet job- specific requirements. Intake Dampers – Powered or gravity dampers prevent unintended air transfer between the outside and space. Unit Mounted Control Center – Factory mounted supply fan starter, overloads, and a Class II transformer for a secondary voltage in the unit. NEMA-3R Remote Starter Control Panel – Provides power to the supply and exhaust fans through either a single-point connection or multiple power connections. Starters, disconnects, Class II transformers, and fusing is provided for each voltage source. • Multiple supply voltages • Wide range of horsepower • Disconnect switch(es) • Control transformer for low voltage remote switching • Terminal strips • Fuse blocks • Electronic motor overload protection Weatherhood – With a combination package, a downturn weatherhood provides a minimum of 36 inches of vertical separation between supply and exhaust air streams and the extended weatherhood provides 10 feet of horizontal separation between supply and exhaust streams. Both configurations are designed to satisfy NFPA 96, simplifying the installation while meeting codes. Supply Voltages – Multiple voltages in single and three phase are available to conveniently match building power. Roof Curbs – Prefabricated roof curbs are available to reduce installation time and costs by ensuring compatibility between the fan and the roof opening. All curbs are lined with fiberglass insulation to prevent condensation and to reduce sound levels. Combination packages allow an exhaust fan and make-up air fan to be mounted on a common curb, with weatherhood options complying with NFPA 96 Standards. See the roof curb section in this catalog for more information. Accessories Untempered Options and Accessories XKSFB. XKSFD. [ 8 ] 10 ft. 3 ft. 10 ft. 3 ft. Provides 10 ft. of horizontal separation for compliance to NFPA 96. 10 Ft. Horizontal Separation - Extended Weatherhood 3 Ft. Vertical Separation - Standard Weatherhood Provides 3 ft. of vertical separation for compliance to NFPA 96. Note: Consult local codes and the authority having jurisdiction if there are questions concerning the use of this product. With either ten feet of horizontal separation or three feet of vertical separation, Accurex has a combination package for your requirements. The Accurex combination package simplifies installation and reduces field labor costs. This pre-engineered design offers the benefit of only one roof penetration for both supply and exhaust ducts, while ensuring complete compatibility and interface between the supply fan, exhaust fan, curb and combination extension. Accurex combination packages are specifically designed to comply with NFPA 96, which states: • Exhaust duct must terminate at least 24 in. above the roof deck. • Fan discharge must terminate at least 40 in. above the roof deck. • There must be at least 10 ft. of horizontal or 3 ft. of vertical separation between the intake and exhaust discharge. Arrangement DB Arrangement HZ Models XKSFB and XKSFD have a compact design that is available in both downblast discharge (arrangement DB) and horizontal discharge (arrangement HZ). Installations may be as stand alone supply fans as pictured at right or as combination packages with exhaust and supply fans on a common curb. Standard Arrangements Combination Packages Untempered Combination Packages XKSFB. XKSFD. [ 9 ] Direct Gas-Fired Units [ 10 ] XDG and XDGK models shall be ETL Listed to ANSI Z83.4 and CAN 3.7. XDGX shall be ETL Listed to ANSI Z83.4-1999, CSA 3.7-M99 (for 100% outdoor air) or ANSI Z83.18- 2000 (for recirculation). [...]... Arrangement DB Horizontal Discharge - Arrangement HZ Combination Packages Kitchen Combination Package The Accurex combination package simplifies installation (model XDG only) and reduces field labor costs The pre -engineered design ensures that the supply fan, exhaust fan, curb, and combination extension components interface properly for kitchen ventilation applications Equally important, Accurex combination... Upblast Discharge - Arrangement UB Horizontal Discharge - Arrangement HZ Kitchen Combination Package The Accurex combination package simplifies installation and reduces field labor costs The pre -engineered design ensures that the supply fan, exhaust fan, curb, and combination extension components interface properly for kitchen ventilation applications Equally important, Accurex combination packages... integrated downturned plenum, eliminating the need for an additional section to achieve a downblast discharge Kitchen Combination Package Downblast Discharge - Arrangement DB The Accurex combination package simplifies installation and reduces field labor costs for kitchen ventilation systems The pre -engineered design ensures that the supply fan, exhaust fan, curb and combination extension components interface... providing a factory engineered interface between the roof curb and the fans It is also designed to satisfy NFPA 96 requirements - above the roof line - for kitchen hood exhaust Note: Consult local codes and the authority having jurisdiction if there are questions concerning the use of this product Thru-Wall Installation Model XDGX (Housing 12, 22, & 32 only) is available with a pre -engineered thru-wall... the unit Remote Control Panels Accurex’s fan control center, model XFCC, is designed to control the exhaust fans, supply fans and lights for the kitchen ventilation system Model XFCC has numerous options and can be interlocked with the fire suppression system Kitchen style remote panels feature lighted toggle switches and a stainless steel face plate for flush mounting to a wall The junction box is also... performance Accurex’s direct gas-fired make-up air units feature: • High-quality cast aluminum burners with stainless steel mixing plates and Maxitrol electronic modulation burner control • Variable volume ventilation capabilities provide energy savings, increased equipment life and enhance employee comfort • All Accurex direct gas-fired heaters are certified to the ANSI Z83.4 safety standard • All blower... deck • Air intake shall have a horizontal separation of 10 feet from the exhaust discharge The combination curb extension is the component that pulls the Combination Package together, providing a factory engineered interface between the roof curb and the fans With a standard 12-inch roof curb, louvered weatherhood, and Accurex model XRUB exhaust fan, the combination curb extension will ensure compliance... Blower Quantity Blower Size 1, 2 or 3 08 — 36 [ 11 ] Direct Gas-Fired Model Comparison XDGK XDG XDGX XDGK Model XDGK is designed to be the most economical, compact, and simple approach to 100% outdoor air kitchen applications Airflow voumes range from 1,500 to 8,500 cfm (2,548 to 14,442 m³/hr) with heating capacities up to 800,000 BTU/hr XDG Model XDG sets the standard for an efficient approach to 100%... Modulation Control Temperature Controls Discharge Temperature Control Discharge Temperature Control w/ Room Override DDC Interface Intake Options Birdscreen Filtered Louvered Remote Control Panels XFCC Kitchen Style Accessories Air Filter Gauge Motorized Dampers Exhaust Fan Starter(s) Inlet Air Sensor 115 Volt Service Receptacle Roof Curbs Equipment Supports Freezestat Special Coatings Fiberglass Insulation... Options and Accessories XMSX Heating Options Hot water, steam and electric heating options are available with the model XMSX The heating section consists of the heating coil factory installed in a pre -engineered coil housing For proper coil sizing, contact your local representative All heating options are available with airflow capacities up to 15,000 cfm (25,485 m³/hr) Hot Water and Steam – Hot water . the products you need for Engineered Kitchen Ventilation Systems. Make-Up Air & Packaged Rooftops Accurex specializes in ventilation comfort—for restaurants. top performing kitchen ventilation products reflect the industry’s latest technological advances and will provide you with a fully integrated ventilation system

Ngày đăng: 20/12/2013, 23:15

Từ khóa liên quan

Tài liệu cùng người dùng

  • Đang cập nhật ...

Tài liệu liên quan