báo cáo khoa học: "care management: A decision-makerresearcher partnership systematic review of effects on process of care and patient outcomes" docx

14 568 0
báo cáo khoa học: "care management: A decision-makerresearcher partnership systematic review of effects on process of care and patient outcomes" docx

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

Thông tin tài liệu

Sahota et al Implementation Science 2011, 6:91 http://www.implementationscience.com/content/6/1/91 Implementation Science SYSTEMATIC REVIEW Open Access Computerized clinical decision support systems for acute care management: A decision-makerresearcher partnership systematic review of effects on process of care and patient outcomes Navdeep Sahota1, Rob Lloyd2,3, Anita Ramakrishna4, Jean A Mackay5, Jeanette C Prorok5, Lorraine Weise-Kelly5, Tamara Navarro5, Nancy L Wilczynski5 and R Brian Haynes3,5,6*, for the CCDSS Systematic Review Team Abstract Background: Acute medical care often demands timely, accurate decisions in complex situations Computerized clinical decision support systems (CCDSSs) have many features that could help However, as for any medical intervention, claims that CCDSSs improve care processes and patient outcomes need to be rigorously assessed The objective of this review was to systematically review the effects of CCDSSs on process of care and patient outcomes for acute medical care Methods: We conducted a decision-maker-researcher partnership systematic review MEDLINE, EMBASE, EvidenceBased Medicine Reviews databases (Cochrane Database of Systematic Reviews, DARE, ACP Journal Club, and others), and the Inspec bibliographic database were searched to January 2010, in all languages, for randomized controlled trials (RCTs) of CCDSSs in all clinical areas We included RCTs that evaluated the effect on process of care or patient outcomes of a CCDSS used for acute medical care compared with care provided without a CCDSS A study was considered to have a positive effect (i.e., CCDSS showed improvement) if at least 50% of the relevant study outcomes were statistically significantly positive Results: Thirty-six studies met our inclusion criteria for acute medical care The CCDSS improved process of care in 63% (22/35) of studies, including 64% (9/14) of medication dosing assistants, 82% (9/11) of management assistants using alerts/reminders, 38% (3/8) of management assistants using guidelines/algorithms, and 67% (2/3) of diagnostic assistants Twenty studies evaluated patient outcomes, of which three (15%) reported improvements, all of which were medication dosing assistants Conclusion: The majority of CCDSSs demonstrated improvements in process of care, but patient outcomes were less likely to be evaluated and far less likely to show positive results Background Computerized clinical decision support systems (CCDSSs) are information systems intended to improve clinical decision-making CCDSSs match individual patient data to a computerized knowledge base that uses software algorithms to generate patient-specific recommendations that are delivered to healthcare practitioners [1-3] * Correspondence: bhaynes@mcmaster.ca Hamilton Health Sciences, 1200 Main Street West, Hamilton, ON, Canada Full list of author information is available at the end of the article This review, acute medical care, is one of a series of six on specific interventions of CCDSSs, including primary preventive care, chronic disease management, diagnostic test ordering, drug prescribing and management, and therapeutic drug monitoring and dosing The review process involved senior healthcare managers in setting priorities and co-sponsoring the review process with an academic review team, and engagement of key clinical leaders in each review to establish review questions, guide data extraction needed for clinical application, and draw conclusions from a practical clinical perspective [4] © 2011 Sahota et al; licensee BioMed Central Ltd This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited Sahota et al Implementation Science 2011, 6:91 http://www.implementationscience.com/content/6/1/91 Expectations are high for the utility of CCDSSs in acute care because acute care in hospitals and emergency rooms is the most intensive and expensive part of the healthcare system on a per patient basis, but many concerns and problems have been identified [5] As with any healthcare intervention, CCDSSs purporting to improve patient care or outcomes should be rigorously evaluated before being routinely implemented in clinical practice [6] This systematic review focuses on the use of CCDSSs for management of medical problems in acute care settings and summarizes the most rigorous evidence to date concerning the effects of CCDSSs in acute medical care An example of such a CCDSS includes advice for paramedics responding to emergency calls Methods Methods for this review are described in detail elsewhere [4] http://www.implementationscience.com/content/5/1/ 12 with pertinent details provided here Page of 14 0.93; 95% confidence interval [CI], 0.91 to 0.94) overall A panel of reviewers–including a physician, a pharmacist, and two individuals trained in health research methods– reviewed eligible studies and assigned them to appropriate care area(s) Acute care referred to episodic health conditions that could be possibly cured or stabilised in less than six months Figure summarizes the study selection process, including specifics for acute care management Several studies addressed two or more clinical care areas; the review for each care area focused only on the study outcomes that were most relevant for that area Most study overlaps for acute care were with therapeutic drug monitoring and drug prescribing Six studies were excluded from acute care after the initial selection Three studies met initial criteria but were later excluded for confounding of healthcare provider across treatment groups (e.g., pharmacist using CCDSS versus physician giving usual care) [7-9] Three studies that met review criteria did not report relevant data for acute care conditions [10-12] Research question Do CCDSSs improve process of care or patient outcomes for acute medical care? Study selection The review was conducted using a partnership model [4] with main groups: decision makers from local health institutions and research staff of the Health Information Research Unit (HIRU) at McMaster University There were two types of decision makers–senior health managers of Hamilton Health Sciences (a large academic health sciences centre) provided overall guidance and endorsement, and a clinical service leader (RL, a pediatrician) provided specific guidance for acute care management HIRU research staff and students were responsible for completing the literature search, and appraising, extracting, and synthesizing the data The goal of the partnership model was to maximize knowledge translation with respect to potential local CCDSS implementation Studies were included if they met all of the following five criteria: evaluated a CCDSS used for acute care; used an randomized controlled trial (RCT) design where patient care with a CCDSS was compared to patient care without a CCDSS; assessed effects among healthcare professionals in clinical practice or post-graduate training; provided patient-specific information in the form of assessments (management options or probabilities) or recommendations to the clinicians, who remained responsible for actual decisions; and measured clinical performance (a measure of process of care) or patient outcomes (including any aspect of patient well-being) Studies were excluded if they provided only summaries of patient information, feedback on groups of patients without individual assessment, or only computer-aided instruction; used simulated patients; or used CCDSSs for image analysis Search strategy Data extraction We reassessed all citations in our most recent review [3] and retrieved new citations from that review’s September 2004 closing date to January 2010, in all languages, by employing a comprehensive search strategy of MEDLINE, EMBASE, Evidence-Based Medicine Reviews databases (Cochrane Database of Systematic Reviews, DARE, ACP Journal Club, and others), and the Inspec bibliographic database Pairs of reviewers independently evaluated each citation and abstract to determine the eligibility of all studies identified in our search Disagreements were resolved by a third reviewer or by consensus Inter-reviewer agreement on study eligibility was measured using the unweighted Cohen’s kappa (), and was excellent ( = Pairs of reviewers independently extracted the following data from all eligible studies: study setting, study methods, CCDSS characteristics, patient characteristics, and outcomes Disagreements were resolved by a third reviewer or by consensus We attempted to contact primary authors of all 36 included studies and 28 authors (78%) replied and confirmed data, including six who had previously replied and confirmed data in our most recent review [3] Partnering with decision makers Assessment of study quality Methodological quality was evaluated using a 10-point scale consisting of five potential sources of bias, and Identification Sahota et al Implementation Science 2011, 6:91 http://www.implementationscience.com/content/6/1/91 Page of 14 Records identified through database searching (n = 14,794) Additional records identified from previous review (n = 86) and through other sources (n = 72) Eligibility Screening Records after duplicates removed (n = 14,188) Records screened (n = 14,188) Full-text articles assessed for eligibility (n = 329) Included Studies included in review series (n = 166) Records excluded (n = 13,859) Full-text articles excluded, with reasons (n = 163) 74 Not RCTs 50 Did not evaluate CCDSS 14 Supplemental reports Severe methodological flaws Did not meet CCDSS definition Did not report outcomes of interest Only abstract published Included in previous review Studies included in this review (met acute care management criteria) (n = 36) Figure Flow diagram of included and excluded studies for the update January 2004 to January 2010 with specifics for acute care management* *Details provided in: Haynes RB et al [4] Two updating searches were performed, for 2004 to 2009 and to January 2010 and the results of the search process are consolidated here based on an extension of the Jadad scale [13] A score of 10 on the scale indicated the highest study quality [4] Assessment of CCDSS intervention effects Studies with multiple treatment arms were counted as a positive study if any of the treatment arms showed a benefit over the control arm Outcomes were considered primary if reported by the author as ‘primary’ or ‘main’ outcomes If no primary outcomes were reported and a power statement was provided, then the outcome on which the power statement was based was considered primary The use of effect sizes was judged to be inappropriate because of the high degree of heterogeneity in almost every aspect of the individual studies Effects for each CCDSS were evaluated based on relevant outcomes showing a statistically significant difference (2p1 primary outcome was reported, only the applicable primary outcomes were evaluated, and judged positive if ≥50% were statistically positive If no primary outcomes were reported (or only some of the primary outcome components were relevant) but overall analyses were provided, the overall analyses were evaluated as primary outcomes Subgroup analyses were not considered If no primary outcomes or overall analyses were reported, or only some components of the primary outcome were relevant for the care area, any reported applicable pre-specified outcomes were evaluated If no clearly pre-specified outcomes were reported, any available relevant outcomes were considered If statistical comparisons were not reported, ‘effect’ was designated as not evaluated (denoted as ) These criteria are more specific than those used in our previous review; therefore, the assignment of effect was adjusted for some studies included in the earlier review Data synthesis and analysis We summarized data and p-values reported in individual studies CCDSS characteristics were analyzed and interpreted with the study as the unit of analysis Data were summarised using descriptive summary measures, including proportions for categorical variables and means (± standard deviation [SD]) for continuous variables All analyses were carried out using SPSS v.15 A 2-sided p < 0.05 indicated statistical significance A sensitivity analysis was conducted to assess the possibility of biased results in studies with a mismatch between the unit of allocation (e.g., clinicians) and the unit of analysis (e.g., individual patients without adjustment for clustering) Success rates comparing studies with matched and mismatched analyses were compared using chi-square for comparisons No differences in reported success were found for either process of care outcomes (Pearson X2 = 2.70, 2p = 0.10) or patient outcomes (Pearson X = 0.39, 2p = 0.53) Accordingly, results have been reported without distinction for mismatch Results Re-examination of the articles included in the prior review [3] yielded 20 articles that met our criteria for acute care [14-33] From the current update (1 January 2004 to January 2010), we screened 11,790 citations for all CCDSS interventions, retrieved 243 full-text articles, and determined that 16 new studies [34-50] met our criteria for acute care (Figure 1), for a total of 36 studies described in 37 articles, published from 1984 to 2009 [14-50] Twenty-six included studies contribute outcomes to this review as well as other CCDSS interventions in the series; one study [26] to four reviews, Page of 14 four studies [19,25,41,47] to three reviews, and 21 studies [14,16-18,21,22,24,27-32,34-36,40,42,48-50] to two reviews; but we focused here on acute care-relevant outcomes Summary of trial quality is reported in Additional file 1, Table S1; system characteristics in Additional file 2, Table S2; study characteristics in Additional file 3, Table S3; outcome data in Additional file 4, Table S4 and Table 1; and other CCDSS-related outcomes in Additional file 5, Table S5 Study quality Based on the 10-point scale for methodological quality, the mean score was 6.4 (95% CI 5.7 to 7.2), with a range from to 10 (see Additional file 1, Table S1) However, the quality of studies increased over time: the mean score was 5.6 (4.6 to 6.6) for the 20 studies from the 2005 review compared with 7.5 (6.7 to 8.3) for the 16 studies retrieved after 2005 (p = 0.01) Fifty-eight percent (21/36) of studies concealed study group allocation before randomization [15,19,23-27,29,33,34,37-42,44-49], and 28% (10/36) of studies employed cluster randomization by practice or physician [16,19,25,26,37-42,48] CCDSS and study characteristics Additional file 2, Table S2 describes key characteristics of the included CCDSSs Denominators vary because not all trials reported on all features considered The CCDSSs were pilot tested in 63% (19/30) of studies [15,17,19,24, 27-30,33,34,36-42,45,46,49], users were trained in the CCDSSs at the time of implementation in 56% (18/32) of studies [17,18,22,23,27,28,31-36,39,41, 42,45,46,49], 97% (33/34) of CCDSSs provided feedback at the time of patient care [14-16,18,19,21-23,25-50], 97% (34/35) of CCDSSs suggested diagnoses/treatment/procedures [14-19,21-43,45-50], and 76% (25/33) of the study authors were also the developers of the CCDSSs [14,15,19,21,23, 25-27,30-42,45-49] Most studies did not report the interface details for the CCDSSs In 59% (20/34) of the studies, the CCDSSs were stand alone systems [14-18,21,22,24,27-30,32,33,35,40,45,46, 49,50], and in 38% (13/34) of the studies, the CCDSS was integrated with a computerized order entry and/or an electronic medical record system [19,20,23,25,26, 31,34,36-39,41,42,47,48] The source of data entry was apparent in 86% (31/36) of the studies [14,17-20,23-49] Data entry was automated via the electronic medical record system in only 29% (9/31) of cases [19,23,25,26, 31,34,41,42,47] The majority (74%, 23/31) used manual data entry (decision-maker [14,18,26-28,32, 36-39,45, 46,48], 39% (12/31); existing staff [17,19,20,24,29, 32,35,47], 26% (8/31); project staff [19,30,40,43-45], 19% (6/31); patient [46], 3% (1/31)) The methods for delivery of the recommendation were clear in 81% (29/36) of Sahota et al Implementation Science 2011, 6:91 http://www.implementationscience.com/content/6/1/91 Page of 14 Table Results for CCDSS trials of acute care Study Methods Score Indication No of centres/ providers/ patients CCDSS Effecta Patient outcomes CCDSS Effect a Terrell, 2009 [48] CCDSS provided alerts to avoid inappropriate prescriptions in geriatric outpatients during discharge from emergency care 1/63*/5,162’ ED visits by older adults that resulted in prescriptions for ≥1 of nine targeted inappropriate medications + Peterson, 2007 [36]b CCDSS provided dosing advice for high-risk drugs in geriatric patients in a tertiary care academic health centre 1/778/2,981* Ratio of prescribed to recommended doses + Kroth, 2006 [39] CCDSS identified low temperature values and generated prompts to repeat measurement in order to improve accuracy of temperature capture by nurses at the bedside of non-critical care hospital patients /337*/90,162 Low temperatures recorded by nursing personnel type + Rood, 2005 [34] CCDSS recommended timing for glucose measurements and administration of insulin in critically ill patients 1/104/484* Deviation between advised and actual glucose measurement times; Time that patients’ glucose levels were within specified range over 10 weeks; Adherence to guideline for timing of glucose measurement + Zanetti, 2003 [47] 1/ /447* Intraoperative redose of antibiotics + Surgical-site infection Selker, 2002 [29] CCDSS provided alarm and alert for redosing of prophylactic antibiotics during prolonged cardiac surgery CCDSS generated recommendations for management of thrombolytic and other reperfusion therapy in acute myocardial infarction 28/ /1,596* Mortality; Stroke; Thrombolysis-related bleeding events requiring transfusion Dexter, 2001 [19] 10 CCDSS provided guideline-based reminders for preventive therapies in hospital inpatients */202/3,416 + Kuperman, 1999 [23] CCDSS detected critical laboratory results for all medical and surgical inpatients and alerted health provider that the results were ready 1/ / * Detection of ST-segment elevation without AMI; Receipt of thrombolytic therapy; Receipt of thrombolytic therapy and contraindications; Treatment of patients with AMI Hospitalizations with an order for therapy; Hospitalizations during which therapy was ordered for an eligible patient Length of time interval from filing alerting result to ordering of appropriate treatment; Filing time and resolution of critical condition + Adverse events within 48 hours of alert Process of care outcomes Management Assistants - Alerts and Reminders Sahota et al Implementation Science 2011, 6:91 http://www.implementationscience.com/content/6/1/91 Page of 14 Table Results for CCDSS trials of acute care (Continued) Overhage, 1997 [26] CCDSS identified corollary orders to prevent errors of omission for any of 87 target tests and treatments in hospital inpatients on a general medicine ward 1*/92/2,181 Compliance with corollary orders; Pharmacist intervention with physicians for significant errors + LOHS; Serum creatinine level Overhage, 1996 [25] 10 CCDSS provided reminders of 22 US Preventive Services Task Force preventive care measures for hospital inpatients, including cancer screening, preventive screening and medications, diabetes care reminders, and vaccinations 1*/78/1,622 Compliance with preventive care guidelines White, 1984 [31] CCDSS identified concerns (drug interactions or signs of potential digoxin intoxication) in inpatients taking digoxin 1/ /396* Physician actions related to alerts + Helder, 2008 [43] CCDSS generated recommendations for management of incubator settings in neonatal ICU 1/117/136* Days to regain birthweight Intraventricular haemorrhage; Sepsis; Mortality Davis, 2007 [42] CCDSS provided evidence-based data relating to appropriate prescribing for upper respiratory tract infections in paediatric outpatients 2/44*/12,195 Prescriptions consistent with evidence-based recommendations + Rothschild, 2007 [37,38] CCDSS generated recommendations for non-emergent inpatient transfusion orders 1/1,414*/3,903 Appropriateness ratings of decision support interventions + Severely undertransfused patients Kuilboer, 2006 [41] 10 CCDSS assisted monitoring and treatment of asthma and COPD in daily practice in primary care 32*/40/156,772 Contacts; Peak total flow; Peak flow ratio; FEV1; FEV1 ratio measurements; Antihistamines prescriptions; Cromoglycate prescriptions; Deptropine prescriptions; Oral bronchodilators prescriptions; Oral corticosteroids prescriptions Paul, 2006 [40] 10 CCDSS assisted management of antibiotic treatment in hospital inpatients 15*/ /2,326 Appropriate antibiotic treatment + Duration of hospital; Duration of fever; Mortality Management Assistants - Guidelines and algorithms Sahota et al Implementation Science 2011, 6:91 http://www.implementationscience.com/content/6/1/91 Page of 14 Table Results for CCDSS trials of acute care (Continued) Brothers, 2004 [46] CCDSS provided recommendations for surgical management of patients with peripheral arterial disease 2/3/206* Agreement between surgeon’s initial and final treatment plan Hamilton, 2004 [44] CCDSS provided evaluation and recommendations of labour progress and need for caesarean sections 7/ /4,993* Caesarean sections Recorded indication of dystocia; Apgar score Hales, 1995 [20] 1/ /1,971* Unnecessary hospital admissions Wyatt, 1989 [33] CCDSS evaluated appropriateness of inpatient admissions CCDSS generated recommendations resulting in identification of highcardiac risk patients among patients with chest pain attending the ED 1/15/153* Overall management accuracy; Time until cardiac care unit admission Diagnostic Assistants Roukema, 2008 [35] CCDSS provided advice for the diagnostic management for children with fever without apparent source in the ED 1/15/164* Test ordering + Time spent at ED Stengel, 2004 [45] CCDSS assisted electronic documentation of diagnosis and findings in patients admitted to orthopaedic ward 1/6/78* Diagnoses per patient + Bogusevicius2002 [15] CCDSS generated diagnosis of acute SBO in surgical inpatients 1/ /80 Diagnosis of acute SBO; Diagnosis of partial SBO; Time to diagnosis Bowel necrosis; Morbidity; Mortality; LOHS; Proportion of patients receiving each type of surgical procedure: open lysis of adhesion; laparoscopic lysis of adhesion; bowel resection Medication Dosing Assistants Cavalcanti, 2009 [49] Saager, 2008 [50] Peterson, 2007 [36]b CCDSS recommended insulin dosing and glucose monitoring to achieve glucose control in patients in ICU CCDSS recommended insulin dosing and glucose assessment frequency for diabetic patients in cardiothoracic ICU 5/60/168* BG measurements obtained per patient; Time with BG controlled + BG during ICU stay; Hypoglycaemia +/0 1/ /40* BG in range (90 to 150 mg/dL); Time in range + Mean BG; Mean time to BG4 mg/L; Trough aminoglycoside levels; Proportion of patients with trough aminoglycoside levels ≥2 mg/L; Length of aminoglycoside therapy Proportion of patients cured; Response to therapy; Treatment failure; Mortality; Indeterminate response; Nephrotoxicity; LOHS; LOHS after start of antibiotics Begg, 1989 [14] ./ /50* Achievement of peak and trough aminoglycoside levels + Mortality; Creatinine clearance during therapy Gonzalez, 1989 [22] CCDSS provided individualised aminoglycoside dosing for inpatients receiving gentamicin or tobramycin CCDSS estimated aminophylline loading and maintenance dosing for ED patients / /67* + Discharged from ED within hours; Adverse effects; Peak flow rate throughout the study Hickling, 1989 [21] Aminophylline loading dose to achieve target serum theophylline level; Aminophylline maintenance dose to achieve target serum theophylline level; Theophylline level Proportion of patients outside of therapeutic range; Peak plasma aminoglycoside levels; Trough levels; Proportion of patients with 48-72 h peak plasma levels + Estimated creatinine clearance during recovery CCDSS provided dosing and dose intervals of aminoglycoside in critically ill patients 1/ /32* Sahota et al Implementation Science 2011, 6:91 http://www.implementationscience.com/content/6/1/91 Page of 14 Table Results for CCDSS trials of acute care (Continued) Carter, 1987 [17] CCDSS provided dosing recommendations for warfarin initiation and adjustments in hospital inpatients 1/ /54* Days from administration of first warfarin dose to achievement of stabilization dosage Time to discharge White, 1987 [32] CCDSS provided dosing recommendations for warfarin therapy in patients hospitalized with DVT, cerebrovascular accident, transient ischemic attack, PE or AF 2/ /75* Time to reach a stable therapeutic dose; Time to reach a therapeutic PR ratio; Patients with PR above therapeutic range during hospital stay; Predicted/observed PR; Absolute error + LOHS; In-hospital bleeding complications + Hurley, 1986 [24] CCDSS provided dosing for theophylline in inpatients with acute air-flow obstruction 1/ /96* Peak expiratory flow rate; Air flow obstruction symptoms; Side effects; Mortality Rodman, 1984 [27] CCDSS recommended lidocaine dosing for patients in intensive or coronary care units 1/ /20* Theophylline levels above therapeutic range; Theophylline levels below therapeutic range; Trough theophylline levels in therapeutic range during oral therapy; Serum theophylline levels; 1st serum level during oral therapy; Trough levels during oral therapy Plasma lidocaine levels in middle of therapeutic range + Toxic response requiring lidocaine discontinuation or dosage reduction Abbreviations: AF, atrial fibrillation; AMI, acute myocardial infarction; BG, blood glucose; CCDSS, computerized clinical decision support system; COPD, chronic obstructive pulmonary disease; DVT, deep vein thrombosis; ED, emergency department; FEV1, forced expiratory volume in second; ICD, International Classification of Diseases; ICU, intensive care unit; INR, international normalised ratio; LOHS, length of hospital stay; PE, pulmonary embolus; PR, prothrombin ratio; SBO, small bowel obstruction *Unit of allocation a Outcomes are evaluated for effect as positive (+) or negative (-) for CCDSS, or no effect (0), based on the following hierarchy An effect is defined as ≥50% of relevant outcomes showing a statistically significant difference (2p < 0.05): If a single primary outcome is reported, in which all components are applicable, this is the only outcome evaluated If >1 primary outcome is reported, the ≥50% rule applies and only the primary outcomes are evaluated If no primary outcomes are reported (or only some of the primary outcome components are relevant) but overall analyses are provided, the overall analyses are evaluated as primary outcomes Subgroup analyses are not considered If no primary outcomes or overall analyses are reported, or only some components of the primary outcome are relevant for the application, any reported prespecified outcomes are evaluated If no clearly prespecified outcomes are reported, any available outcomes are considered If statistical comparisons are not reported, ‘effect’ is designated as not evaluated ( ) b Study included in two categories the studies, with the most common method of delivery being through a desktop/laptop computer [19,23,25,26, 28,32,34-43,47-49] (62%, 18/29) Most CCDSSs had multiple user groups: 78% (28/36) were physicians [14-22,24-29,31,32,34-38,40-42,45-48], 47% (17/36) were trainees [16,17,19,22,23,25,26,31-33,36-39,42,43,45,48], 19% (7/36) were advanced practice nurses [30,35,36, 39,43,46,47], 8% (3/36) were pharmacists [27,32,36], and 22% (8/36) were other health professionals [20,33,34,39, 42,44,49,50] Eligible studies were conducted in 121 different clinics at 106 sites, involving over 3,417 healthcare practitioners and 202,491 patients (see Additional file 3, Table S3) Fifty-three percent (19/36) of studies were missing data on the number of practitioners [14-18,20-24,27-29,31, 32,40,44,47,50], 6% (2/36) were missing data on the number of patients [23,39], and 11% (4/36) were missing data on both the number of clinics and sites [14,19, 22,39] Some of the 36 studies were conducted in more than one country, but most studies were conducted in the United States [16-20,22,23,25-27,29,31,32,36-39, 42,44,46-48,50] (61%, 22/36), followed by the Netherlands [34,35,41,43] (11%, 4/36), the United Kingdom [28,30,33] (8%, 3/36), Germany [40,45] and New Zealand [14,21] (6% each, 2/36), and Australia [24], Brazil [49], Canada [44], Denmark [28], Israel [40], Italy [40], Sahota et al Implementation Science 2011, 6:91 http://www.implementationscience.com/content/6/1/91 Lithuania [15], Norway [28], and Portugal [28] (3% each, 1/36) Fifty-eight percent of the studies reported solely public funding [16,17,19,23,25-30,33,35,37-42,46-48,50], 8% (3/36) reported solely private funding [21,22,36], 6% (2/36) reported both private and public funding [24,49], and 28% (10/36) did not report their funding source [14,15,18,20,31,32,34,43-45] CCDSS effectiveness Table provides a summary of the effect of CCDSSs on process of care and patient outcomes (detailed outcome information is provided in Additional file 4, Table S4) Among studies that reported sufficient data for analysis, 63% (22/35) reported an improvement in process of care outcomes [14,19,21-23,26-28,31,32,34-36,36-40,42, 45,47-50] and 15% (3/20) reported an improvement in patient outcomes [32,49,50] One of the studies that reported an improvement in process of care outcomes, Cavalcanti 2009, had two patient outcomes: one showed a benefit with CCDSS for blood sugar control compared with conventional care, but at the expense of increased hypoglycemic episodes Studies could be organised into four separate categories, management assistants–alerts/reminders, management assistants–guidelines/algorithms, diagnostic assistants, and medication dosing assistants, with only one study [36] falling into two categories Page 10 of 14 usual care Kroth et al had the largest patient population in this group (N = 90,162) and tested a CCDSS which helped improve the accuracy of temperature capture by nurses for non-critical care hospital patients [39] The study reported a decrease in the number of (presumed erroneous) low temperatures recorded by nurses in the CCDSS group compared to usual care Kuperman et al tested a CCDSS that notified health providers when critical laboratory results for all medical and surgical inpatients were ready [23] In comparison to usual care, the CCDSS group reduced the time from recording the alert to ordering the appropriate treatment Zanetti et al provided alerts for redosing of prophylactic antibiotics during prolonged cardiac surgery and showed an increase in the number of intraoperative redoses compared to usual care [47] The CCDSS in White et al identified signs and risk factors for digoxin intoxication for inpatients [31] The trial reported an increase in the number of physician actions related to the alerts in the CCDSS group compared to usual care Rood et al developed a guideline for tight glycaemic control in intensive care unit (ICU) patients and compared a CCDSS version to the paper-based system [34] Use of the CCDSS resulted in stricter adherence to the guideline, both in terms of timing of glucose measurements and use of advised insulin doses This resulted in a small improvement in patient glycaemic control; however, the improvement was judged to be not clinically important Management assistants - alerts and reminders Eleven trials tested a management assistant using alerts and reminders, such as alerting pharmacists to possible drug interactions [29,31,36,47,48] or giving reminders to physicians for preventive therapies like vaccines [19,23,25,26,34,39] Nine of the 11 trials (82%) that evaluated process of care outcomes demonstrated an improvement [19,23,26,31,34,36,39,47,48], and none of four studies assessing patient outcomes showed improvement The studies of highest quality in this group all produced improvements in process of care outcomes Overhage et al tested a CCDSS that generated corollary orders to prevent errors of omission for any of 87 target tests and treatments in hospital inpatients [26] In comparison to a computerized order entry system alone, compliance with corollary orders was increased in the CCDSS group and the number of pharmacist interventions with physicians for significant errors was decreased Another high-quality study, Dexter et al., gave reminders for preventive therapies in hospital inpatients and showed an increase in the proportion of eligible hospitalized patients who received the targeted preventive therapy [19] Terrell et al assessed a CCDSS that provided alerts to avoid inappropriate prescriptions in geriatric outpatients during discharge from emergency care [48] Inappropriate medication prescriptions decreased in the CCDSS group when compared to Management assistants - guidelines and algorithms Nine studies [20,33,37,38,40-44,46] examined a management assistant employing guidelines and algorithms–these CCDSSs generated recommendations for the management of acute health issues using guidelines or algorithms, such as evidence-based electronic prescribing in paediatric care [42] Of the eight studies that assessed process of care outcomes, three (38%) demonstrated improvements [37,38,40, 42], and none of the four studies that assessed patient outcomes showed an improvement Process improvements occurred in a multicentre study of high methodological quality by Paul et al [40] The CCDSS assisted with choice of empiric antibiotic treatment in hospital inpatients and improved appropriate antibiotic therapy in comparison to usual care Davis et al assessed appropriate prescribing for upper respiratory tract infections in paediatric outpatients [42] Compared to usual care, the CCDSS increased prescriptions that were consistent with evidence-based recommendations Rothschild et al tested a CCDSS that produced recommendations for non-emergent inpatient transfusion orders, and showed improvement in guideline adherence as measured by the percentage of appropriate and inappropriate transfusion orders [37,38] The methodologically sound study by Kuilboer et al had the largest patient population Sahota et al Implementation Science 2011, 6:91 http://www.implementationscience.com/content/6/1/91 of all the acute care trials (N = 156,772), but did not report any improvements in process of care for monitoring and treatment of asthma and chronic obstructive pulmonary disease (COPD) in primary care [41] Diagnostic assistants Three studies tested diagnostic assistants [15,35,45]– these CCDSSs provided advice for the diagnosis of acute health conditions, such as acute small bowel obstruction in surgical inpatients [15] All studies assessed process of care outcomes with two (67%) showing improvements with the CCDSS [35,45] Roukema et al tested a CCDSS that provided advice for the diagnostic management of children with fever without an apparent source in the emergency department (ED) and showed an increase in test ordering [35] Stengel et al examined a CCDSS that assisted electronic documentation of diagnosis and findings in patients admitted to orthopaedic wards [45] In comparison to standard paper forms, the CCDSS demonstrated success in improving diagnosis per patient Of the two studies examining patient outcomes, neither demonstrated an improvement Medication dosing assistants Fourteen studies evaluated medication dosing assistants, providing recommendations specific to drug dosing adjustments, such as insulin dosing or dosing advice for warfarin initiation [14,16-18,21,22,24,27,28,30,32,36, 49,50] These CCDSSs showed improvements in process of care outcomes in of 14 studies (64%) [14,21,22,27, 28,32,36,49,50], improvements in patient outcomes in of 10 studies (30%) [32,49,50], and a negative effect on patient outcomes in of 10 (10%) studies [49] Many studies in the Medication Dosing Assistants section overlap with studies in the therapeutic drug monitoring and thus, are not the primary focus of this review A more in-depth analysis of these studies is provided in the therapeutic drug monitoring and dosing review (submitted to IS for consideration of publication as part of this series of six reviews) Costs and practical process related outcomes Additional file 5, Table S5 provides data on CCDSS costs and practical process related outcomes, such as the impact on workflow and practitioner satisfaction Only 11% (4/36) of studies assessed CCDSS monetary costs [16,26,39,40], and 17% assessed other practical process-related outcomes [33,34,39,45,47,49] Discussion Our systematic review identified 36 RCTs of CCDSSs for acute care The trials were diverse in CCDSS design, clinical settings, clinical problems, and measured effects Study quality scores increased over time, but that may Page 11 of 14 be due to an improvement in the reporting of trials Most studies evaluated process of care effects, with 63% showing benefit (benefit was based on at least 50% of the relevant study outcomes being statistically significantly positive) [14,19,21-23,26-28,31,32,34-36,3640,42,45,47-50] Few examined meaningful patient outcomes, and none showed significant reductions in major patient morbidity or mortality, although some found small reductions in length of hospital stay [16,26,32, 40,50] Lack of findings for patient-important outcomes may be largely an issue of study design, especially the size of the study Most studies involved few participants, suggesting that they were preliminary in nature, attempting to establish whether the CCDSS could change the process of care, as a prelude to larger studies assessing whether lives could be saved Some studies did demonstrate substantial effects on the process of care For example, the multicentre trial by Paul et al used a causal probabilistic network and local susceptibility data to develop a CCDSS called the TREAT system, which suggested empiric antibiotic regimens based on basic data entered by practitioners during the work-up of patients with new infections [40] When compared to pathogens isolated further in the course of disease, the TREAT recommendations significantly bettered the physician-only prescriptions (odds ratio of 1.48) Costs were also shown to be reduced, and length of stay was reduced by one day In the case of reminders and alerts, where the effect on the process of care is a strong surrogate for patient outcomes, it could also be argued that evidence of effect on patient outcomes is not needed For example, Terrell et al developed a group of alerts within a computerized physician order entry system to warn emergency physicians when they were about to prescribe potentially dangerous medications (as defined by externally validated criteria) to elderly patients on discharge from the department [48] The system carried a message explaining why the medication could be dangerous, who had made the recommendation, and links to further explanatory information Perhaps most importantly, it also suggested safer substitute therapies for each warning Physicians in the computer-assisted group prescribed fewer inappropriate medications than physicians with no access to the alerts It is difficult to make general recommendations regarding the broad applicability and effectiveness of CCDSSs in acute care settings given the current literature and heterogeneity of the individual studies Several practical details identified as pertinent for extraction by the decision-makers (such as implementation details and costs) were not reported in sufficient detail or with adequate consistency across studies to summarize There are certainly encouraging trends witnessed by a number of recent high-quality studies demonstrating positive Sahota et al Implementation Science 2011, 6:91 http://www.implementationscience.com/content/6/1/91 Page 12 of 14 CCDSS characteristics and CCDSS success, and ensuring studies of high methodological quality Fortunately, with recent initiatives on the adoption of electronic medical records to achieve meaningful enhancements of healthcare [52], there are many opportunities for good measurement and assessment of CCDSSs in acute care The high quality studies to date show that it is feasible to rigorously evaluate CCDSSs; the findings so far underscore that existing CCDSSs have not been shown to improve patient-important outcomes process of care outcomes Important effects on patient outcomes have yet to be convincingly demonstrated, however, and purchasers and decision makers are advised to take this into consideration We did not complete a formal analysis of the factors associated with success across the trials However, confirming findings from our previous review [3], when study authors were also the developers of the CCDSSS under assessment, the findings were more likely to be favourable for the CCDSS This could be due to any number of factors including, for example, greater attention to customization for local settings, choosing outcomes more likely to be influenced by CCDSSs, influence of developers on enthusiasm for use of the system, or bias in the analysis of findings, which has been documented for commercial trials of pharmaceuticals [51] As such, the included trials are potentially more likely to overestimate the size of the effect and increase the risk of a type I error in this review Conclusions The majority of CCDSSs demonstrated improvements in process of care but patient outcomes were less likely to be evaluated and far less likely to show positive results CCDSSs for acute medical care have not matured to degree that clinical decision makers should embrace the technology for clinical application Limitations Additional material A number of studies did not report relevant data or had insufficient data to conduct the appropriate analyses For example, we were unable to evaluate the effect size for process of care or patient outcomes for several of the studies As well, our strict inclusion criteria that included only RCTs focuses on only the most scientifically sound studies and would miss, for example, more effective CCDSSSs that were not as rigorously tested The heterogeneity between studies in CCDSS features and outcome measures was too great to justify a meta-analysis to pool effect sizes Instead, the overall results of the trials were reported by taking the number of trials with statistically significant results and dividing them by the total number of trials, a method known as vote-counting, which is limited by giving equal weight to each study, regardless of individual merit and size A study was considered to have a positive effect (i.e., CCDSS showed improvement) if at least 50% of the relevant study outcomes were statistically significantly positive Many of the studies were small, increasing the risk of type (false negative) error On the other hand, it is likely that publication bias exists in this field, as shown in many others, such that the number of ‘negative’ trials is underestimated from the published literature The majority of studies were conducted in the US and academic medical institutions, where the nature of the clinical landscape could have affected the application and results from the CCDSSs, reducing their generalizability to other settings Last, but perhaps most important, very few studies evaluated patient-important outcomes Future research directions Future research should focus on evaluating the effect of CCDSSs on patient outcomes, providing full details of the CCDSS to help establish the relationship between Additional file 1: Study methods scores for trials of acute care management Methods scores for the included studies Additional file 2: CCDSS characteristics for trials of acute care management CCDSS characteristics of the included studies Additional file 3: Study characteristics for trials of acute care management Study characteristics of the included studies Additional file 4: Results for CCDSS trials of acute care management Details results of the included studies Additional file 5: Costs and CCDSS process-related outcomes for trials of acute care management Cost and CCDSS process-related outcomes for the included studies Acknowledgements The research was funded by a Canadian Institutes of Health Research Synthesis Grant: Knowledge Translation KRS 91791 The members of the Computerized Clinical Decision Support System (CCDSS) Systematic Review Team included the Principal Investigator, Co-Investigators, Co-Applicants/ Senior Management Decision-makers, Co-Applicants/Clinical Service Decision-Makers, and Research Staff The following were involved in collection and/or organization of data: Jeanette Prorok, MSc, McMaster University; Nathan Souza, MD, MMEd, McMaster University; Brian Hemens, BScPhm, MSc, McMaster University; Robby Nieuwlaat, PhD, McMaster University; Shikha Misra, BHSc, McMaster University; Jasmine Dhaliwal, BHSc, McMaster University; Navdeep Sahota, BHSc, University of Saskatchewan; Anita Ramakrishna, BHSc, McMaster University; Pavel Roshanov, BSc, McMaster University; Tahany Awad, MD, McMaster University Nicholas Hobson Dip.T., Chris Cotoi BEng, EMBA, and Rick Parrish Dip.T., at McMaster University provided programming and information technology support Author details College of Medicine, University of Saskatchewan, 107 Wiggins Road, Saskatoon, SK, Canada 2Department of Pediatrics, McMaster University, 1280 Main Street West, Hamilton, ON, Canada 3Hamilton Health Sciences, 1200 Main Street West, Hamilton, ON, Canada 4McMaster University, 1280 Main Street West, Hamilton, ON, Canada 5Health Information Research Unit, Department of Clinical Epidemiology and Biostatistics, McMaster University, 1280 Main Street West, Hamilton, ON, Canada 6Department of Medicine, McMaster University, 1280 Main Street West, Hamilton, ON, Canada Sahota et al Implementation Science 2011, 6:91 http://www.implementationscience.com/content/6/1/91 Authors’ contributions RBH was responsible for study conception and design; acquisition, analysis, and interpretation of data; drafting and critical revision of the manuscript; obtaining funding; study supervision He is the guarantor NS acquired, analyzed, and interpreted the data; and drafted the manuscript RL analyzed and interpreted data; and critically revised the manuscript AR drafted the manuscript JAM acquired, analyzed, and interpreted data; drafted the manuscript; critically revised the manuscript; and provided administrative, technical, or material support JCP acquired, analyzed, and interpreted data; drafted the manuscript; provided statistical analysis; and provided administrative, technical, or material support LWK and TN acquired data and drafted the manuscript NLW acquired, analyzed, and interpreted data; drafted the manuscript; provided administrative, technical, or material support; and provided study supervision All authors read and approved the final manuscript Competing interests RBH, NLW, JAM, LWK, TN, JCP, NS, RL, and AR received support through the Canadian Institutes of Health Research Synthesis Grant: Knowledge Translation KRS 91791 for the submitted work RBH is acquainted with several CCDSS developers and researchers, including authors of papers included in this review Received: April 2011 Accepted: August 2011 Published: August 2011 References Johnston ME, Langton KB, Haynes RB, Mathieu A: Effects of Computerbased Clinical Decision Support Systems on Clinician Performance and Patient Outcome: A Critical Appraisal of Research Ann Intern Med 1994, 120(2):135-142 Hunt DL, Haynes RB, Hanna SE, Smith K: Effects of Computer-Based Clinical Decision Support Systems on Physician Performance and Patient Outcomes: A Systematic Review JAMA 1998, 280(15):1339-1346 Garg AX, Adhikari NK, McDonald H, Rosas-Arellano M, Devereaux PJ, Beyene J, Sam J, Haynes RB: Effects of computerized clinical decision support systems on practitioner performance and patient outcomes: a systematic review JAMA 2005, 293(10):1223-1238 Haynes RB, Wilczynski N, the Computerized Clinical Decision Support System (CCDSS) Systematic Review Team: Effects of computerized clinical decision support systems on practitioner performance and patient outcomes: Methods of a decision-maker-researcher partnership systematic review Implement Sci 2010, 5:12 Berner ES: Clinical decision support systems: State of the Art Rockville, Maryland: Agency for Healthcare Research and Quality; 2009 Randolph AG, Haynes RB, Wyatt JC, Cook DJ, Guyatt GH: Users’ Guides to the Medical Literature: XVIII How to Use an Article Evaluating the Clinical Impact of a Computer-Based Clinical Decision Support System JAMA 1999, 282(1):67-74 Mungall DR, Anbe D, Forrester PL, Luoma T, Genovese R, Mahan J, LeBlanc S, Penney JB: A prospective randomized comparison of the accuracy of computer-assisted versus GUSTO nomogram–directed heparin therapy Clin Pharmacol Ther 1994, 55(5):591-596 Lecomte F, Oppenheimer A, Ginsburg C, Dhainaut JF, Claessens YE: Computer-assisted prescription improves the delay of morphine infusion after nurse triage in patients admitted in the emergency department with intense pain: a randomized trial JEUR 2006, 19(4):177-182 East TD, Heermann LK, Bradshaw RL, Lugo A, Sailors RM, Ershler L, Wallace CJ, Morris AH, McKinley B, Marquez A, Tonnesen A, Parmley L, Shoemaker W, Meade P, Thaut P, Hill T, Young M, Baughman J, Olterman M, Gooder V, Quinn B, Summer W, Valentine V, Carlson J, Steinberg K: Efficacy of computerized decision support for mechanical ventilation: results of a prospective multi-center randomized trial Proc AMIA Symp 1999, 251-255 10 McDonald CJ, Hui SL, Smith DM, Tierney WM, Cohen SJ, Weinberger M, McCabe GP: Reminders to physicians from an introspective computer medical record A two-year randomized trial Ann Intern Med 1984, 100(1):130-138 11 Rogers JL, Haring OM, Goetz JP: Changes in patient attitudes following the implementation of a medical information system QRB Qual Rev Bull 1984, 10(3):65-74 Page 13 of 14 12 Verstappen SMM, Jacobs JWG, Van der Veen MJ, Heurkens AHM, Schenk Y, Ter Borg EJ, Blaauw AAM, Bijlsma JWJ: Intensive treatment with methotrexate in early rheumatoid arthritis: aiming for remission Computer Assisted Management in Early Rheumatoid Arthritis (CAMERA, an open-label strategy trial) Ann Rheum Dis 2007, 66(11):1443-1449 13 Jadad AR, Moore RA, Carroll D, Jenkinson C, Reynolds DJM, Gavaghan DJ, McQuay HJ: Assessing the quality of reports of randomized clinical trials: Is blinding necessary? Control Clin Trials 1996, 17(1):1-12 14 Begg EJ, Atkinson HC, Jeffery GM, Taylor NW: Individualised aminoglycoside dosage based on pharmacokinetic analysis is superior to dosage based on physician intuition at achieving target plasma drug concentrations Br J Clin Pharmacol 1989, 28(2):137-141 15 Bogusevicius A, Maleckas A, Pundzius J, Skaudickas D: Prospective randomised trial of computer-aided diagnosis and contrast radiography in acute small bowel obstruction Eur J Surg 2002, 168(2):78-83 16 Burton ME, Ash CL, Hill DP Jr, Handy T, Shepherd MD, Vasko MR: A controlled trial of the cost benefit of computerized bayesian aminoglycoside administration Clin Pharmacol Ther 1991, 49(6):685-694 17 Carter BL, Taylor JW, Becker A: Evaluation of three dosage-prediction methods for initial in-hospital stabilization of warfarin therapy Clin Pharm 1987, 6(1):37-45 18 Casner PR, Reilly R, Ho H: A randomized controlled trial of computerized pharmacokinetic theophylline dosing versus empiric physician dosing Clin Pharmacol Ther 1993, 53(6):684-690 19 Dexter PR, Perkins S, Overhage JM, Maharry K, Kohler RB, McDonald CJ: A computerized reminder system to increase the use of preventive care for hospitalized patients N Engl J Med 2001, 345(13):965-970 20 Hales JW, Gardner RM, Jacobson JT: Factors impacting the success of computerized preadmission screening Proc Annu Symp Comput Appl Med Care 1995, 728-732[http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2579189/ pdf/procascamc00009-0757.pdf] 21 Hickling K, Begg E, Moore ML: A prospective randomised trial comparing individualised pharmacokinetic dosage prediction for aminoglycosides with prediction based on estimated creatinine clearance in critically ill patients Intensive Care Med 1989, 15(4):233-237 22 Gonzalez ER, Vanderheyden BA, Ornato JP, Comstock TG: Computerassisted optimization of aminophylline therapy in the emergency department Am J Emerg Med 1989, 7(4):395-401 23 Kuperman GJ, Teich JM, Tanasijevic MJ, Ma’Luf N, Rittenberg E, Jha A, Fiskio J, Winkelman J, Bates DW: Improving response to critical laboratory results with automation: results of a randomized controlled trial J Am Med Inform Assoc 1999, 6(6):512-522 24 Hurley SF, Dziukas LJ, McNeil JJ, Brignell MJ: A randomized controlled clinical trial of pharmacokinetic theophylline dosing Am Rev Respir Dis 1986, 134(6):1219-1224 25 Overhage JM, Tierney WM, McDonald CJ: Computer reminders to implement preventive care guidelines for hospitalized patients Arch Intern Med 1996, 156(14):1551-1556 26 Overhage JM, Tierney WM, Zhou XH, McDonald CJ: A randomized trial of ‘corollary orders’ to prevent errors of omission J Am Med Inform Assoc 1997, 4(5):364-375 27 Rodman JH, Jelliffe RW, Kolb E, Tuey DB, de Guzman MF, Wagers PW, Haywood LJ: Clinical studies with computer-assisted initial lidocaine therapy Arch Intern Med 1984, 144(4):703-709 28 Poller L, Shiach CR, MacCallum PK, Johansen AM, Munster AM, Magalhaes A, Jespersen J: Multicentre randomised study of computerised anticoagulant dosage European Concerted Action on Anticoagulation Lancet 1998, 352(9139):1505-1509 29 Selker HP, Beshansky JR, Griffith JL, TPI Trial Investigators: Use of the electrocardiograph-based thrombolytic predictive instrument to assist thrombolytic and reperfusion therapy for acute myocardial infarction A multicenter, randomized, controlled, clinical effectiveness trial Ann Intern Med 2002, 137(2):87-95 30 Vadher B, Patterson DL, Leaning M: Evaluation of a decision support system for initiation and control of oral anticoagulation in a randomised trial BMJ 1997, 314(7089):1252-1256 31 White KS, Lindsay A, Pryor TA, Brown WF, Walsh K: Application of a computerized medical decision-making process to the problem of digoxin intoxication J Am Coll Cardiol 1984, 4(3):571-576 32 White RH, Hong R, Venook AP, Daschbach MM, Murray W, Mungall DR, Coleman RW: Initiation of warfarin therapy: comparison of physician Sahota et al Implementation Science 2011, 6:91 http://www.implementationscience.com/content/6/1/91 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 dosing with computer-assisted dosing J Gen Intern Med 1987, 2(3):141-148 Wyatt J: Lessons learnt from the field trial of ACORN, an expert system to advise on chest pain Proc Sixth World Conf Med Inform 1989, 111-115 Rood E, Bosman RJ, van der Spoel JI, Taylor P, Zandstra DF: Use of a computerized guideline for glucose regulation in the intensive care unit improved both guideline adherence and glucose regulation J Am Med Inform Assoc 2005, 12(2):172-180 Roukema J, Steyerberg EW, van der Lei J, Moll HA: Randomized trial of a clinical decision support system: impact on the management of children with fever without apparent source J Am Med Inform Assoc 2008, 15(1):107-113 Peterson JF, Rosenbaum BP, Waitman LR, Habermann R, Powers J, Harrell D, Miller RA: Physicians’ response to guided geriatric dosing: initial results from a randomized trial Stud Health Technol Inform 2007, 129(Pt 2):1037-1040 Rothschild JM, McGurk S, Honour M, Fiskio J, Avorn J, Cook EF, Kaufman R, Churchill WH, Bates DW: The impact of computerized decision support guidelines on transfusion practice Transfusion 2004, 44(s1):3A Rothschild JM, McGurk S, Honour M, Lu L, McClendon AA, Srivastava P, Churchill WH, Kaufman RM, Avorn J, Cook EF, Bates DW: Assessment of education and computerized decision support interventions for improving transfusion practice Transfusion 2007, 47(2):228-239 Kroth PJ, Dexter PR, Overhage JM, Knipe C, Hui SL, Belsito A, McDonald CJ: A computerized decision support system improves the accuracy of temperature capture from nursing personnel at the bedside AMIA Annu Symp Proc 2006, 444-448 Paul M, Andreassen S, Tacconelli E, Nielsen AD, Almanasreh N, Frank U, Cauda R, Leibovici L, TREAT Study G: Improving empirical antibiotic treatment using TREAT, a computerized decision support system: cluster randomized trial J Antimicrob Chemother 2006, 58(6):1238-1245 Kuilboer MM, van Wijk MA, Mosseveld M, van der Does E, de Jongste JC, Overbeek SE, Ponsioen B, van der Lei J: Computed critiquing integrated into daily clinical practice affects physicians’ behavior–a randomized clinical trial with AsthmaCritic Methods Inf Med 2006, 45(4):447-454 Davis RL, Wright J, Chalmers F, Levenson L, Brown JC, Lozano P, Christakis DA: A cluster randomized clinical trial to improve prescribing patterns in ambulatory pediatrics PLoS Clin Trials 2007, 2(5):e25 Helder OK, Mulder PG, van Goudoever JB: Computer-generated versus nurse-determined strategy for incubator humidity and time to regain birthweight J Obstet Gynecol Neonatal Nurs 2008, 37(3):255-261 Hamilton E, Platt R, Gauthier R, McNamara H, Miner L, Rothenberg S, Asselin G, Sabbah R, Benjamin A, Lake M, Vintzileos A: The effect of computer-assisted evaluation of labor on cesarean rates J Health Care Qual 2004, 26(1):37-44 Stengel D, Bauwens K, Walter M, Kopfer T, Ekkernkamp A: Comparison of handheld computer-assisted and conventional paper chart documentation of medical records A randomized, controlled trial J Bone Joint Surg Am 2004, 86A(3):553-560 Brothers TE, Cox MH, Robison JG, Elliott BM, Nietert P: Prospective decision analysis modeling indicates that clinical decisions in vascular surgery often fail to maximize patient expected utility J Surg Res 2004, 120(2):278-287 Zanetti G, Flanagan HL Jr, Cohn LH, Giardina R, Platt R: Improvement of intraoperative antibiotic prophylaxis in prolonged cardiac surgery by automated alerts in the operating room Infect Control Hosp Epidemiol 2003, 24(1):13-16 Terrell KM, Perkins AJ, Dexter PR, Hui SL, Callahan CM, Miller DK: Computerized decision support to reduce potentially inappropriate prescribing to older emergency department patients: a randomized, controlled trial J Am Geriatr Soc 2009, 57(8):1388-1394 Cavalcanti AB, Silva E, Pereira AJ, Caldeira-Filho M, Almeida FP, Westphal GA, Beims R, Fernandes CC, Correa TD, Gouvea MR, Eluf-Neto J: A randomized controlled trial comparing a computer-assisted insulin infusion protocol with a strict and a conventional protocol for glucose control in critically ill patients J Crit Care 2009, 24(3):371-378 Saager L, Collins GL, Burnside B, Tymkew H, Zhang L, Jacobsohn E, Avidan M: A randomized study in diabetic patients undergoing cardiac surgery comparing computer-guided glucose management with a standard sliding scale protocol J Cardiothorac Vasc Anesth 2008, 22(3):377-382 Page 14 of 14 51 Lexchin J, Bero LA, Djulbegovic B, Clark O: Pharmaceutical industry sponsorship and research outcome and quality: systematic review BMJ 2003, 326(7400):1167-1170 52 The Office of the National Coordinator for Health Information Technology [http://healthit.hhs.gov/portal/server.pt/community/ healthit_hhs_gov home/1204] doi:10.1186/1748-5908-6-91 Cite this article as: Sahota et al.: Computerized clinical decision support systems for acute care management: A decision-maker-researcher partnership systematic review of effects on process of care and patient outcomes Implementation Science 2011 6:91 Submit your next manuscript to BioMed Central and take full advantage of: • Convenient online submission • Thorough peer review • No space constraints or color figure charges • Immediate publication on acceptance • Inclusion in PubMed, CAS, Scopus and Google Scholar • Research which is freely available for redistribution Submit your manuscript at www.biomedcentral.com/submit ... databases (Cochrane Database of Systematic Reviews, DARE, ACP Journal Club, and others), and the Inspec bibliographic database Pairs of reviewers independently evaluated each citation and abstract to... for consideration of publication as part of this series of six reviews) Costs and practical process related outcomes Additional file 5, Table S5 provides data on CCDSS costs and practical process. .. guarantor NS acquired, analyzed, and interpreted the data; and drafted the manuscript RL analyzed and interpreted data; and critically revised the manuscript AR drafted the manuscript JAM acquired,

Ngày đăng: 10/08/2014, 11:20

Từ khóa liên quan

Mục lục

  • Abstract

    • Background

    • Methods

    • Results

    • Conclusion

    • Background

    • Methods

      • Research question

      • Partnering with decision makers

      • Search strategy

      • Study selection

      • Data extraction

      • Assessment of study quality

      • Assessment of CCDSS intervention effects

      • Data synthesis and analysis

      • Results

        • Study quality

        • CCDSS and study characteristics

        • CCDSS effectiveness

        • Management assistants - alerts and reminders

        • Management assistants - guidelines and algorithms

        • Diagnostic assistants

        • Medication dosing assistants

Tài liệu cùng người dùng

  • Đang cập nhật ...

Tài liệu liên quan