Low Voltage Products User manual Masterpact NW08-63 IEC potx

54 375 0
Low Voltage Products User manual Masterpact NW08-63 IEC potx

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

Thông tin tài liệu

Low Voltage Products User manual Masterpact NW08-63 IEC Masterpact NW08-63 IEC Schneider Electric 1 Discovering Masterpact 2 Using Masterpact 8 Understanding the controls and indications 8 Charging the circuit breaker 9 Closing the circuit breaker 10 Opening the circuit breaker 11 Resetting after a fault trip 12 Locking the controls 13 Using the Masterpact drawout chassis 16 Identifying the circuit breaker positions 16 Racking 17 Matching a Masterpact circuit breaker with its chassis 19 Locking the switchboard door 20 Locking the circuit breaker in position 21 Locking the safety shutters 24 Identifying the electrical auxiliaries 26 Identification of the connection terminals 26 Electrical diagrams 27 Operation 29 Discovering Masterpact's accessories 30 Micrologic control units 30 Indication contacts 31 Auxiliaries for remote operation 33 Device mechanical accessories 35 Chassis mechanical accessories 37 Inspecting and testing before use 40 Initial test 40 What to do when the circuit breaker trips 41 Maintaining Masterpact performance 42 Recommended maintenance program 42 Maintenance operations 43 Ordering replacement parts 45 Troubleshooting and solutions 46 Checking Masterpact operating conditions 48 User manual for circuit breakers Masterpact NW08-63 IEC Masterpact NW08-63 IEC Schneider Electric 2 Discovering Masterpact The Masterpact NW range of circuit breakers and switch-disconnectors offer current ratings from 800 A to 6300 A. Five different performance levels are available: b N1: standard with total discrimination b H1: high performance with total discrimination b H2: a compromise between current limiting and discrimination b H3: high breaking capacity and discrimination, without current limiting b L1: high level of current limiting, with some discrimination. Rating plate E60350A E51288A E60036A Icu kA at 415 V Ics = 100% Icu 150 100 65 42 L1 H3 H2 H1 N1 160012001000800 2000 2500 3200 4000 5000 6300 E46004A Masterpact NW08-63 IEC Schneider Electric 3 Masterpact NW08-63 IEC Schneider Electric 4 Discovering Masterpact Masterpact circuit breakers are available in drawout and fixed versions. The drawout version is mounted on a chassis and the fixed version is installed using fixing brackets Drawout version Fixed version E51205C E51289C Masterpact NW08-63 IEC Schneider Electric 5 Chassis E60037A Masterpact NW08-63 IEC Schneider Electric 6 Circuit breaker / switch-disconnector E60038A MCH gear motor for electrical charging of the operating mechanism Operating-mechanism charging handle PF "ready to close" contact SDE/2 "fault-trip" indication contact or Res electrical remote reset Terminal block for the control unit and the SDE contact(s) MX/2 opening release or MN undervoltage release XF closing release MX/1 opening release Closing pushbutton Opening pushbutton Operation counter Carrying grip SDE/1 "fault-trip" indication contact Arc chute Block of 4 OF "ON/OFF" indication contacts Terminal block for the control auxiliaries 2 Blocks of 4 additional OF "ON/OFF" contacts or EF combined "connected/closed" contacts Keylocking kit Locking by padlocks BPFE electrical closing pushbutton Control unit Terminal block for the ON/OFF indication contacts Discovering Masterpact Masterpact NW08-63 IEC Schneider Electric 7 Front E60039A RESET Indicator for position of the main contacts "Springs charged" and "Ready to close" indicator Locking by padlock or lead-seal cover for pushbuttons Rating plate Trip indication button used to reset before closing Masterpact NW08-63 IEC Schneider Electric 8 Using Masterpact Understanding the controls and indications Circuit breaker open and discharged Circuit breaker closed and discharged Circuit breaker open, charged and not "ready to close" Circuit breaker closed, charged and not "ready to close" Circuit breaker open, charged and "ready to close" E51320B Push OFF O I Push O N Push OFF O I Push ON Push OFF O I Push O N Push OFF O I Push O N E51207A E51210A E51206A E51211 E51209A Push OFF O I Push ON T e s t RESET [...]... E51272A KIRK 15 Masterpact NW08-63 IEC Schneider Electric Identifying the circuit breaker positions Using the Masterpact drawout chassis E51222A The indicator on the front signals the position of the circuit breaker in the chassis Test Test E51219A E51314A b "connected" position Test E51315A E51220A b "test" position Test 26 mm E51316A E51221A b "disconnected" position Test 16 Masterpact NW08-63 IEC Schneider... tabs and push the rails in 1 E51226B E51224B Press the release tabs and pull the rails out Test Test 2 17 Masterpact NW08-63 IEC 3 Schneider Electric Using the Masterpact drawout chassis Racking For complete information on Masterpact handling and mounting, see the installation manual( s) Inserting Masterpact Open the circuit breaker (in any case, it opens automatically during connection) E51217A E51227A... connected-position carriage switch d> 25.4 mm 29 Masterpact NW08-63 IEC Schneider Electric Micrologic control units E51329A Micrologic control units For more in-depth information, see the control-unit user manual E46108A Discovering Masterpact' s accessories b standard equipment, one per device b long-time rating plug and connection cables not included, see below: Micrologic 2.0 Micrologic 5.0 Micrologic... series with the PF "ready to close" contact 10 Masterpact NW08-63 IEC Schneider Electric Opening the circuit breaker E51217A E51216A Locally Press the OFF pushbutton I ON Push E51293A Push Remotely Use one of the following solutions: b one or two MX opening releases (MX1 and MX2, 0.7 to 1.1 Un) b one MN undervoltage release (0.35 to 0.7 Un) b one MN undervoltage release (0.35 to 0.7 Un) with a delay... position 18 Masterpact NW08-63 IEC Schneider Electric Matching a Masterpact circuit breaker with its chassis The mismatch protection ensures that a circuit breaker is installed only in a chassis with compatible characteristics The possible combinations are listed below E51317B To set up a mismatch-prevention combination for the circuit breaker and the chassis, see the mismatch-prevention installation manual. .. each shutter: v shutter open v shutter closed E60042A Padlocking or position indication on the front Test 25 Masterpact NW08-63 IEC Test Schneider Electric Identification of the connection terminals Layout of terminal blocks E60352A Identifying the electrical auxiliaries 26 Masterpact NW08-63 IEC Schneider Electric Electrical diagrams Fixed and drawout devices The diagram is shown with circuits de-energised,... may be charged manually using the charging handle or the optional MCH gear motor E60370A The charge status is indicated as follows Manual charging: Pull the handle down seven times until you hear a "clack" O E51213A OFF Push Automatic charging: If the MCH gear motor is installed, the spring is automatically recharged after each closing E51290A I ON Push or Test 9 Masterpact NW08-63 IEC Schneider Electric... 236 235 234 Masterpact NW08-63 IEC BCDE BCDF BCDG BCEF BCEG BDEF BDEG BDFG CDEF CDEG CEFG DEFG 167 157 147 146 137 136 135 134 127 126 124 123 Schneider Electric Locking the switchboard door Using the Masterpact drawout chassis E51231B The locking device is installed on the left or right-hand side of the chassis: b when the circuit breaker is in "connected" or "test" position, the latch is lowered and... the latch is raised and the door is unlocked Test Disabling door opening Put the Masterpact in "test" or "connected" position Test The door is locked E51233A E51235A E51232A Close the door Enabling door opening Test 20 The door is unlocked E51236A E51234A Put the Masterpact in "disconnected" position Masterpact NW08-63 IEC Schneider Electric Locking the circuit breaker in position Combination of locking... connection cables not included, see below: one PF contact b connection cables: v for fixed device v for drawout device 32 b the contact indicates that the device may be closed because all the following are valid: v circuit breaker is open v spring mechanism is charged v a maintained closing order is not present v a maintained opening order is not present Masterpact NW08-63 IEC b changeover contact b rated . Low Voltage Products User manual Masterpact NW08-63 IEC Masterpact NW08-63 IEC Schneider Electric 1 Discovering Masterpact 2 Using Masterpact 8 Understanding the. Masterpact operating conditions 48 User manual for circuit breakers Masterpact NW08-63 IEC Masterpact NW08-63 IEC Schneider Electric 2 Discovering Masterpact The Masterpact NW range of circuit breakers. Icu 150 100 65 42 L1 H3 H2 H1 N1 160012001000800 2000 2500 3200 4000 5000 6300 E46004A Masterpact NW08-63 IEC Schneider Electric 3 Masterpact NW08-63 IEC Schneider Electric 4 Discovering Masterpact Masterpact circuit breakers are available

Ngày đăng: 05/07/2014, 01:20

Từ khóa liên quan

Tài liệu cùng người dùng

Tài liệu liên quan