SAMPLING AND SURVEYING RADIOLOGICAL ENVIRONMENTS - CHAPTER 9 potx

6 302 0
SAMPLING AND SURVEYING RADIOLOGICAL ENVIRONMENTS - CHAPTER 9 potx

Đang tải... (xem toàn văn)

Thông tin tài liệu

311 CHAPTER 9 Equipment Decontamination When performing environmental investigations, all sampling equipment must be treated as if it is contaminated, and therefore should be thoroughly decontaminated between sampling points. Decontamination procedures for radiologically and chem- ically contaminated equipment are presented in Sections 9.1 and 9.2, respectively. Decontamination is defined as the process of removing, neutralizing, washing, and rinsing surfaces of equipment and personal protective clothing to minimize the potential for contaminant migration. Decontamination is performed to assure the collection of representative environmental samples. The only way to eliminate decontamination is by using disposable equipment. It is critical to test the effectiveness of any decontamination procedure so that the credibility of environmental samples cannot be questioned. For radiological contaminants, this is accomplished by scanning the decontaminated equipment and by collecting swipe samples for radiological counting. If the results from the scanning measurements and swipe sampling exceed radiological release limits, additional decontamination steps must be taken to remove the contamination. If the results are below the release limit, the equipment may be released for use in collecting additional samples. For highly radioactive environments, the equipment may not be able to be decontaminated sufficiently to meet the release limits. Sampling equipment that cannot meet the release limits should be disposed of. Large equipment (used to support sampling activities) that cannot meet the release limits may in some instances still be used as long as it does not come in direct contact with the samples being collected. In this situation, every effort should be made to reduce the amount of removable contamination. For chemical contaminants, testing the effectiveness of the decontamination procedure is accomplished through the preparation of equipment rinsate blank sam- ples which are prepared by pouring ASTM Type II reagent-grade (or equivalent) water over decontaminated sampling equipment, and collecting the rinsate in sample bottles. The rinsate sample is then shipped to the laboratory and is analyzed for the same parameters as the environmental sample. If the results from the analysis of equipment rinsate samples identify contamination, the chemical decontamination © 2001 by CRC Press LLC 312 SAMPLING AND SURVEYING RADIOLOGICAL ENVIRONMENTS procedure was proved to be ineffective. In this case, the analytical data for any samples collected with the contaminated equipment should not be used. The decontamination of large equipment and sampling equipment should be performed as close to the study area as possible to prevent the possible spread of contamination. 9.1 RADIOLOGICAL DECONTAMINATION PROCEDURE The following four methods are available to support the decontamination of radiologically contaminated equipment, and are presented in order for increasing levels of contamination. One should begin with the first decontamination method that is practical. If the first method used is not effective in removing the contami- nation, proceed to the next method. 9.1.1 Tape Method 1. Apply masking tape or duct tape to the surface of the equipment. 2. Remove the tape. 3. Repeat Steps 1 and 2 until the entire surface of the equipment has been covered. 4. Scan the surfaces of the equipment for gross alpha and gross beta/gamma activity to determine if equipment meets radiological release limits. 5. Collect swipe samples from the areas showing the highest activity (based on the scanning measurements) to determine if equipment meets radiological release limits for removable gross alpha and gross beta/gamma activity. 6. If radiological release limits have been met, release the equipment for reuse. If radiological release limits have not been met, proceed to Section 9.1.2 and perform the next level of decontamination. 7. Document the results from the scanning surveys and the swipe samples. 8. When practical, wrap the equipment in plastic sheeting or aluminum foil to keep it clean prior to use. 9.1.2 Manual Cleaning Method 1. Remove soil adhering to equipment by scraping, brushing (wire brush), or wiping. 2. Wash thoroughly with a strong nonphosphate detergent/soap wash. 3. Rinse equipment with tap water. 4. Rinse equipment with ASTM Type II (or equivalent) water. Note, this step is only required when decontaminating sampling equipment. 5. Allow equipment to air dry. 6. Scan the surfaces of the equipment for gross alpha and gross beta/gamma activity to determine if equipment meets radiological release limits. 7. Collect swipe samples from the areas showing the highest activity (based on the scanning measurements) to determine if equipment meets radiological release limits. 8. If radiological release limits have been met, release the equipment for reuse. If radiological release limits have not been met, proceed to Section 9.1.3. 9. Document the results from the scanning surveys and the swipe samples. © 2001 by CRC Press LLC EQUIPMENT DECONTAMINATION 313 10. When practical, wrap the equipment in plastic sheeting or aluminum foil to keep it clean prior to use. 9.1.3 HEPA Vacuum Method 1. Remove soil adhering to equipment by scraping, brushing (wire brush), or wiping. 2. Use a HEPA Vacuum system to vacuum surfaces of the equipment. 3. Rinse equipment with tap water. 4. Rinse equipment with ASTM Type II (or equivalent) water. Note, this step is only required when decontaminating sampling equipment. 5. Allow equipment to air dry. 6. Scan the surfaces of the equipment for gross alpha and gross beta/gamma activity to determine if equipment meets radiological release limits. 7. Collect swipe samples from the areas showing the highest activity (based on the scanning measurements) to determine if equipment meets radiological release limits. 8. If radiological release limits have been met, release the equipment for reuse. If radiological release limits have not been met, proceed to Section 9.1.4. 9. Document the results from the scanning surveys and the swipe samples. 10. When practical, wrap the equipment in plastic sheeting or aluminum foil to keep it clean prior to use. 9.1.4 High-Pressure Wash Method 1. Remove soil adhering to equipment by scraping, brushing (wire brush), or wiping. 2. Use a pressure washer to steam clean equipment thoroughly with potable water and a nonphosphatic laboratory-grade detergent. The pressure washer should pro- duce a minimum water pressure of 80 psi and a minimum temperature of 180˚F. 3. Use a pressure washer to rinse equipment with tap water. 4. Rinse equipment with ASTM Type II (or equivalent) water. Note, this step is only required when decontaminating sampling equipment. 5. Allow equipment to air dry. 6. Scan the surfaces of the equipment for gross alpha and gross beta/gamma activity to determine if equipment meets radiological release limits. 7. Collect swipe samples from the areas showing the highest activity (based on the scanning measurements) to determine if equipment meets radiological release limits. 8. If radiological release limits have been met, release the equipment for reuse. If radiological release limits have not been met for sampling equipment, dispose of equipment. If radiological release limits have not been met for large equipment, it may be considered for reuse only if does not come in direct contact with the samples being collected. 9. Document the results from the scanning surveys and the swipe samples. 10. When practical, wrap the equipment in plastic sheeting or aluminum foil to keep it clean prior to use. © 2001 by CRC Press LLC 314 SAMPLING AND SURVEYING RADIOLOGICAL ENVIRONMENTS 9.2 CHEMICAL DECONTAMINATION PROCEDURE 9.2.1 Large Equipment The following method should be used to decontaminate all types of large equip- ment used to support chemical sampling activities (e.g., drilling augers, drill bit, A- rod). 1. Remove soil adhering to equipment by scraping, brushing (wire brush), or wiping. 2. Use a pressure washer to steam clean equipment thoroughly with potable water and a nonphosphatic laboratory-grade detergent. The pressure washer should pro- duce a minimum water pressure of 80 psi and a minimum temperature of 180˚F. 3. Use a pressure washer to rinse equipment with tap water. 4. Allow equipment to air dry. 5. When practical, wrap the equipment in plastic sheeting or aluminum foil to keep it clean prior to use. 9.2.2 Sampling Equipment The following methods should be used to decontaminate all types of equipment used to perform chemical sampling activities. This equipment includes but is not limited to: • Deep soil sampling equipment (e.g., split-spoon, thin-walled tube samplers) • Shallow soil sampling equipment (e.g., hand augers, core sampler) • Sediment sampling equipment (e.g., box sampler, core sampler) • Surface water/groundwater sampling equipment (e.g., dipper, bailer, bladder pump) • Concrete/asphalt sampling equipment (e.g., core barrel) • Paint sampling equipment (e.g., spatula) • Air sampling equipment • Support equipment coming in contact with sample (e.g., discharge lines, bowls, spoons) When samples are to be analyzed for inorganics, a dilute hydrochloric or nitric acid solution rinse must be used in the decontamination procedure. Dilute hydro- chloric acid is generally preferred over nitric acid when cleaning stainless steel because nitric acid may oxidize this material. When samples are to be analyzed for organic contaminants, the equipment decontamination procedure should include a rinse with pesticide-grade acetone and hexane, in that order. Pesticide-grade methanol may be used instead of acetone. When samples are to be analyzed for both inorganics and organics, a dilute hydro- chloric or nitric acid solution rinse must be used in combination with a pesticide- grade acetone and hexane rinse. Below are three equipment decontamination procedures. The first procedure should be used when samples are to be analyzed for inorganic parameters only. The second procedure should be used when samples are to be analyzed for organic © 2001 by CRC Press LLC EQUIPMENT DECONTAMINATION 315 parameters only, and the third should be used if samples are to be analyzed for both organic and inorganic parameters. Inorganic Procedure 1. Remove soil adhering to equipment by scraping, brushing (wire brush), or wiping. 2. Wash thoroughly with a strong nonphosphate detergent/soap wash. 3. Rinse thoroughly with tap water. 4. Rinse with ASTM Type II (or equivalent) water. 5. Rinse with dilute hydrochloric or nitric acid solution. 6. Rinse with ASTM Type II (or equivalent) water. 7. Allow equipment to air dry. 8. Wrap equipment in aluminum foil (shiny side out) to keep it clean prior to use. Organic Procedure 1. Remove soil adhering to equipment by scraping, brushing (wire brush), or wiping. 2. Wash thoroughly with a strong nonphosphate detergent/soap wash. 3. Rinse thoroughly with tap water. 4. Rinse with ASTM Type II (or equivalent) water. 5. Rinse with pesticide-grade acetone (or methanol). 6. Rinse with pesticide-grade hexane. 7. Allow equipment to air dry. 8. Wrap equipment in aluminum foil (shiny side out) to keep it clean prior to use. Combined Inorganic/Organic Procedure 1. Remove soil adhering to equipment by scraping, brushing (wire brush), or wiping. 2. Wash thoroughly with a strong nonphosphate detergent/soap wash. 3. Rinse thoroughly with tap water. 4. Rinse with ASTM Type II (or equivalent) water. 5. Rinse with dilute hydrochloric or nitric acid solution. 6. Rinse with ASTM Type II (or equivalent) water. 7. Rinse with pesticide-grade acetone (or methanol). 8. Rinse with pesticide-grade hexane. 9. Allow equipment to air dry. 10. Wrap equipment in aluminum foil (shiny side out) to keep it clean prior to use. The dilute acid solution, acetone, hexane, and distilled/deionized water are most easily handled when they are contained within Teflon squirt bottles. Squirt bottles made of substances other than Teflon should not be used, since they have the potential to contaminate the solutions. When using these solutions, the drippings should be caught in a bucket or tub. The acetone and hexane drippings should be allowed to volatilize into the air, while the acid solution drippings should be neutralized using baking soda. Decontaminating pumps is more difficult than other sampling equipment since many of them are not easy to disassemble. The procedure to use for these tools is to place the pump in a large decontamination tub full of nonphosphate detergent © 2001 by CRC Press LLC 316 SAMPLING AND SURVEYING RADIOLOGICAL ENVIRONMENTS and tap water. The pump is turned on, which forces the wash water through the pump and discharge line. The same procedure is repeated in a tub full of clean tap water. The outside of the pump and outside of the pressure and discharge lines are then decontaminated using the sampling decontamination methods described above. All of the water generated from this decontamination procedure must be con- tainerized and then analytically tested to determine the appropriate method for disposal. Discharge permits must be acquired from the city and/or county prior to discharging decontamination water into any sanitary or storm sewer system. REFERENCES EPA (Environmental Protection Agency), A Compendium of Superfund Field Operations Methods, EPA/540/P-87/001a, 1987. EPA (Environmental Protection Agency), RCRA Facility Investigation (RFI) Guidance, PB89- 200299, 1989. © 2001 by CRC Press LLC . Superfund Field Operations Methods, EPA/540/P-87/001a, 198 7. EPA (Environmental Protection Agency), RCRA Facility Investigation (RFI) Guidance, PB8 9- 200 299 , 198 9. © 2001 by CRC Press LLC . detergent © 2001 by CRC Press LLC 316 SAMPLING AND SURVEYING RADIOLOGICAL ENVIRONMENTS and tap water. The pump is turned on, which forces the wash water through the pump and discharge line. The same procedure. thoroughly decontaminated between sampling points. Decontamination procedures for radiologically and chem- ically contaminated equipment are presented in Sections 9. 1 and 9. 2, respectively. Decontamination

Ngày đăng: 18/06/2014, 19:20

Mục lục

  • Table of Contents

  • CHAPTER 9: Equipment Decontamination

    • 9.1 RADIOLOGICAL DECONTAMINATION PROCEDURE

      • 9.1.1 Tape Method

      • 9.1.2 Manual Cleaning Method

      • 9.1.3 HEPA Vacuum Method

      • 9.1.4 High-Pressure Wash Method

      • 9.2 CHEMICAL DECONTAMINATION PROCEDURE

        • 9.2.1 Large Equipment

        • 9.2.2 Sampling Equipment

        • REFERENCES

        • APPENDIX A: Data Quality Objectives Summary Report Template

        • APPENDIX B: Sampling and Analysis Plan Template

        • APPENDIX C: Statistical Tables

        • APPENDIX D: Metric Conversion Chart

        • APPENDIX E: Radiological Decay Chains

        • APPENDIX F: Sample Containers, Preservation, and Holding Times

Tài liệu cùng người dùng

  • Đang cập nhật ...

Tài liệu liên quan