0
  1. Trang chủ >
  2. Công Nghệ Thông Tin >
  3. Phần cứng >

CopperTen® Four-Pair Plenum Cable

CopperTen® Four-Pair Plenum Cable

CopperTen® Four-Pair Plenum Cable

... ISO/IEC 11801 Class EA Ed. 2.1 horizontal cable requirements• 4/08•104196AE CopperTen ® Four-Pair Plenum Cable TrueNet ® CopperTen ® Four-Pair Plenum Cable 2 www.adc.com • +1-952-938-8080 • ... Operation: -20° to 75 °C (-4° to 167 °F) 4/08•104196AE CopperTen ® Four-Pair Plenum Cable TrueNet ® CopperTen ® Four-Pair Plenum Cable 3 www.adc.com • +1-952-938-8080 • 1-800-366-3891 FREQ (MHz) ... www.adc.com • +1-952-938-8080 • 1-800-366-3891 Spec Sheet TrueNet ® CopperTen ® Four-Pair Plenum Cable An integral part of ADC’s TrueNet ® Structured Cabling System, CopperTen ® is the...
  • 4
  • 229
  • 0
Tài liệu 25-Pair Category 5e Plenum Cable docx

Tài liệu 25-Pair Category 5e Plenum Cable docx

... CMP• ETL verified TIA/EIA-568-B.2 Category 5E horizontal cable requirements7 / 0 7 • 1 0 4 7 5 3 A E 25-Pair Category 5e Plenum Cable 2w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 ... Operating Voltage (Max): 300 VDC Worst Case Cable Skew: 45 ns/100 m Nominal Velocity of Propagation: 72%7 / 0 7 • 1 0 4 7 5 3 A E 25-Pair Category 5e Plenum Cable 3w w w . a d c . c o m • + 1 - ... • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1TrueNet®25-Pair Category 5e Plenum Cable SpecificationsCHARACTERISTICS: Conductor: 24 AWG solid bare copper Insulation: 100%...
  • 4
  • 208
  • 0
Tài liệu Category 6 Four-Pair Plenum Cable ppt

Tài liệu Category 6 Four-Pair Plenum Cable ppt

... Verified TIA/EIA-568-B.2-1 Category 6 horizontal cable requirements6/05 • 1324655 Category 6 Four-Pair Plenum Cable TrueNet®Category 6 Four-Pair Plenum Cable 2www.adc.com • +1-952-938-8080 • 1-800-366-3891SpecificationsCONSTRUCTIONFeatures ... VDCWorst case cable skew: 25 nS/100 meters (25 nS/328 ft)Nominal velocity of propagation: 73%6/05 • 1324655 Category 6 Four-Pair Plenum Cable TrueNet®Category 6 Four-Pair Plenum Cable 3www.adc.com ... TrueNet®Category 6 Four-Pair Plenum Cable SPEC SHEET SPEC SHEET www.adc.com • +1-952-938-8080 • 1-800-366-3891ADC’s TrueNet®Category 6 plenum cable, with best in class performance,...
  • 4
  • 198
  • 0
Tài liệu Category 5e Four-Pair Plenum Cable pptx

Tài liệu Category 5e Four-Pair Plenum Cable pptx

... verified TIA/EIA-568-B.2 Category 5e horizontal cable requirements6/05 • 1324675 Category 5e Four-Pair Plenum Cable TrueNet®Category 5e Four-Pair Plenum Cable 2www.adc.com • +1-952-938-8080 • 1-800-366-3891SpecificationsCONSTRUCTIONFeatures ... VDCWorst case cable skew: 25 nS/100 meters (25 nS/328 ft)Nominal velocity of propagation: 75%6/05 • 1324675 Category 5e Four-Pair Plenum Cable TrueNet®Category 5e Four-Pair Plenum Cable 3www.adc.com ... TrueNet®Category 5e Four-Pair Plenum Cable SPEC SHEET SPEC SHEET www.adc.com • +1-952-938-8080 • 1-800-366-3891ADC’s TrueNet®Category 5e plenum cable is an integral part of the...
  • 4
  • 312
  • 0
Tài liệu Fiber Optic Cable Armored Compact Building Cables: Plenum docx

Tài liệu Fiber Optic Cable Armored Compact Building Cables: Plenum docx

... Fiber Optic Cable Armored Compact Building Cables: Plenum SPEC SHEET www.adc.com • +1-952-938-8080 • 1-800-366-3891ADC’s plenum armored compact buildingcables are designed for ... (UL) 910, NEC OFCP, FT-68/05 • 1330094 Armored Compact Building Cables: Plenum Fiber Optic Cable Armored Compact Building Cables: Plenum 2www.adc.com • +1-952-938-8080 • 1-800-366-3891ENVIRONMENTAL ... ˚F)Specifications Plenum Outer Jacket900 µm Tight Buffered FiberDielectric CentralStrength MemberAramid Yarn Strength Member Plenum Inner JacketInterlocking AluminumArmor Plenum Inner and...
  • 4
  • 298
  • 0
Tài liệu CopperTen® Four-Pair Riser Cable doc

Tài liệu CopperTen® Four-Pair Riser Cable doc

... Category 6a horizontal cable requirements•TrueNet®CopperTen® Four-Pair Riser Cable 5/08•104976AE CopperTen® Four-Pair Riser Cable TrueNet®CopperTen® Four-Pair Riser Cable 2www.adc.com ... Operation: -20°to75°C(-4°to167°F)5/08•104976AE CopperTen® Four-Pair Riser Cable TrueNet®CopperTen® Four-Pair Riser Cable 3www.adc.com • +1-952-938-8080 • 1-800-366-3891NOTE: The ... Capacitance @ 20° C (68° F) (Max): 5.6nF/100m(17pF/ft) Operating Voltage (Max): 300 VDC Worst Case Cable Skew: 40 ns/100 m (40 ns/ 328 ft) Nominal Velocity of Propagation: 65%ENVIRONMENTAL CHARACTERISTICS...
  • 4
  • 209
  • 0
Tài liệu Fiber Optic Cable Breakout Cables: Riser and Plenum docx

Tài liệu Fiber Optic Cable Breakout Cables: Riser and Plenum docx

... • 1330108 Breakout Cables: Riser and Plenum Fiber Optic Cable Breakout Cables: Riser and Plenum 2www.adc.com • +1-952-938-8080 • 1-800-366-3891 PLENUM AND RISER, 8 FIBER CABLE Specifications*NOTE: ... Temperature 0˚ to 70 ˚C (32˚ to 158 ˚F)8/05 • 1330108 Breakout Cables: Riser and Plenum Fiber Optic Cables: Breakout Cables: Riser and Plenum 3www.adc.com • +1-952-938-8080 • 1-800-366-3891TRANSMISSION ... Fiber Optic Cable Breakout Cables: Riser and Plenum ADC’s breakout cables offer quick and easyconnector installation onto jacketed fibereliminating...
  • 4
  • 294
  • 0
Tài liệu Fiber Optic Cable Two-Fiber LCF™ Distribution Cable: Plenum and Riser doc

Tài liệu Fiber Optic Cable Two-Fiber LCF™ Distribution Cable: Plenum and Riser doc

... Fiber Optic Cable Two-Fiber LCF™Distribution Cable: Plenum and RiserSPEC SHEET www.adc.com • +1-952-938-8080 • 1-800-366-3891ADC’s Two-Fiber LCF™Distribution Cable iseasy to strip ... Plenum & RiserFiber Optic Cable Two-Fiber LCF™Distribution Cable: Plenum and Riser2www.adc.com • +1-952-938-8080 • 1-800-366-3891ENVIRONMENTAL CHARACTERISTICS: PLENUM Storage Temperature ... Optical FiberCables-Part 2• Telcordia GR-409-CORE, EIA/TIA FOTPs• TIA/EIA 568-B• (UL) 910, NEC OFNP, FT-6• (UL) 1666, NEC OFNR, FT-48/05 • 1331199 Two-Fiber LCF™Dist. Cables: Plenum &...
  • 4
  • 248
  • 0
Tài liệu CopperTen® Four Pair F/UTP Riser Cable pdf

Tài liệu CopperTen® Four Pair F/UTP Riser Cable pdf

... Horizontal Cable RequirementsTIA/EIA-568-B.2-10 Augmented Category 6 Horizontal Cable RequirementsISO/IEC 11801 Category 6 Horizontal Cable RequirementsISO/IEC 11801 Category 6a Horizontal Cable ... warranty•4/08•104744AECopperTen® Four Pair F/UTP Riser Cable 2www.adc.com • +1-952-938-8080 • 1-800-366-3891TrueNet®CopperTen® Four Pair F/UTP Riser Cable SpecificationsCONSTRUCTIONConductor: 23 ... +1-952-938-8080 • 1-800-366-3891Spec SheetTrueNet®CopperTen® Four Pair F/UTP Riser Cable ADC F/UTP CopperTen® cable can be used in data center, communications closet and work station for 10G...
  • 4
  • 226
  • 0
Tài liệu Basic Structured Cabling Systems Category 5e 4-Pair Plenum Data Cable pdf

Tài liệu Basic Structured Cabling Systems Category 5e 4-Pair Plenum Data Cable pdf

... TIA/EIA-568-B.2 Category 5e horizontal cable requirements7/07 • 101849AE Category 5e 4-Pair Plenum Cable Basic Structured Cabling SystemsCategory 5e 4-Pair Plenum Data Cable 2www.adc.com • +1-952-938-8080 ... case cable skew: 25 nS/100 meters (25 nS/328 ft)Nominal velocity of propagation: 76%7/07 • 101849AE Category 5e 4-Pair Plenum Cable Basic Structured Cabling SystemsCategory 5e 4-Pair Plenum ... Basic Structured Cabling SystemsCategory 5e 4-Pair Plenum Data Cable SPEC SHEET SPEC SHEET www.adc.com • +1-952-938-8080 • 1-800-366-3891ADC’s Basic Category...
  • 4
  • 332
  • 0

Xem thêm

Từ khóa: chuyên đề điện xoay chiều theo dạngNghiên cứu sự hình thành lớp bảo vệ và khả năng chống ăn mòn của thép bền thời tiết trong điều kiện khí hậu nhiệt đới việt namNghiên cứu tổ chức pha chế, đánh giá chất lượng thuốc tiêm truyền trong điều kiện dã ngoạiNghiên cứu tổ hợp chất chỉ điểm sinh học vWF, VCAM 1, MCP 1, d dimer trong chẩn đoán và tiên lượng nhồi máu não cấpNghiên cứu tổ chức chạy tàu hàng cố định theo thời gian trên đường sắt việt namGiáo án Sinh học 11 bài 13: Thực hành phát hiện diệp lục và carôtenôitGiáo án Sinh học 11 bài 13: Thực hành phát hiện diệp lục và carôtenôitTrả hồ sơ điều tra bổ sung đối với các tội xâm phạm sở hữu có tính chất chiếm đoạt theo pháp luật Tố tụng hình sự Việt Nam từ thực tiễn thành phố Hồ Chí Minh (Luận văn thạc sĩ)Nghiên cứu về mô hình thống kê học sâu và ứng dụng trong nhận dạng chữ viết tay hạn chếNghiên cứu tổng hợp các oxit hỗn hợp kích thƣớc nanomet ce 0 75 zr0 25o2 , ce 0 5 zr0 5o2 và khảo sát hoạt tính quang xúc tác của chúngĐịnh tội danh từ thực tiễn huyện Cần Giuộc, tỉnh Long An (Luận văn thạc sĩ)Chuong 2 nhận dạng rui roQuản lý nợ xấu tại Agribank chi nhánh huyện Phù Yên, tỉnh Sơn La (Luận văn thạc sĩ)Tranh tụng tại phiên tòa hình sự sơ thẩm theo pháp luật tố tụng hình sự Việt Nam từ thực tiễn xét xử của các Tòa án quân sự Quân khu (Luận văn thạc sĩ)Giáo án Sinh học 11 bài 14: Thực hành phát hiện hô hấp ở thực vậtGiáo án Sinh học 11 bài 14: Thực hành phát hiện hô hấp ở thực vậtGiáo án Sinh học 11 bài 14: Thực hành phát hiện hô hấp ở thực vậtTrách nhiệm của người sử dụng lao động đối với lao động nữ theo pháp luật lao động Việt Nam từ thực tiễn các khu công nghiệp tại thành phố Hồ Chí Minh (Luận văn thạc sĩ)Chiến lược marketing tại ngân hàng Agribank chi nhánh Sài Gòn từ 2013-2015HIỆU QUẢ CỦA MÔ HÌNH XỬ LÝ BÙN HOẠT TÍNH BẰNG KIỀM