... the name implies, a constant “exchange” ofdata between the particle counter software package and a SCADA software package.The particle counter data are output to a temporary location in the computer’smemory ... gasoline.The data may be transmitted in any type of format, referred to as a “protocol.”These protocols are not standardized, and a lot of effort can be expended in “trans-lating” the data ... into usable form. Many laypeople are confused by the distinctionbetween the industry standard signal formats (RS-485 and RS-232) and the non-standard protocols. To make an analogy, the signal...
  • 7
  • 406
  • 0
A Practical Guide to Particle Counting for Drinking Water Treatment - Chapter 3 ppt

A Practical Guide to Particle Counting for Drinking Water Treatment - Chapter 3 ppt

... at a time. If a spareis available it can be rotated into service. The maintenance log should be kept up- to- date, and calibration stickers displaying the date of calibration placed on each particle ... practical. 2. Particle Counter Calibration Verification Verifying calibration is an easier and more practical step for the water plantoperator. Only a couple of particle sizes are required, and ... maintenance schedule should account for seasonal changes, and be adjustedaccordingly. Permanganate is often added seasonally, and can cause coating prob-lems. Any change in the process that can affect...
  • 17
  • 545
  • 0
A Practical Guide to Particle Counting for Drinking Water Treatment - Chapter 8 ppt

A Practical Guide to Particle Counting for Drinking Water Treatment - Chapter 8 ppt

... typicallycommunicated every minute.The comparator provides a simple way to convert the particle size informationfrom an analog pulse to a digital count value. It is a very basic form of analog -to- digital ... analog -to- digital (A/ D) conversion. 1. Voltage Comparator A comparator is simply a small circuit that “compares” an input signal to a fixedreference voltage. If the input signal is greater than ... signal level for the smallestsize particle (usually 2 µm). Once adjustments have been made and the 2 to 1signal -to- noise ratio has been achieved, the voltage values corresponding to eachparticle...
  • 7
  • 372
  • 1
A Practical Guide to Particle Counting for Drinking Water Treatment - Chapter 9 ppt

A Practical Guide to Particle Counting for Drinking Water Treatment - Chapter 9 ppt

... voltage range of a chart recorder or SCADA analoginput is 1 to 5 V. A 250 Ω resistor is required to convert a 4 to 20 mA signal into a 1 to 5 V signal.Another benefit of the 4 to 20 mA current ... some cases, flow alarms can be signaled by the particle counter via the computer data collection system. A. DIAGNOSTIC SIGNALS, ALARMS, AND DISPLAYS The most common alarm found on particle ... LLC AUXILIARY FEATURES 97 A second method maintains a constant sample time, but varies the number ofparticles counted. For instance, on low-concentration filtered waters, every particle may...
  • 5
  • 297
  • 0
A Practical Guide to Particle Counting for Drinking Water Treatment - Chapter 14 ppt

A Practical Guide to Particle Counting for Drinking Water Treatment - Chapter 14 ppt

... constant, high-quality, and rea-sonably affordable standard for size calibration of particle counters.C. PARTICLE SIZE CALIBRATION To calibrate a particle counter for sizing accuracy, standards covering ... wideracceptance in the drinking water treatment industry. The desire for standards for both instrument accuracy and cross-comparison of data has placed an increasingamount of scrutiny on particle ... VERIFICATION OF CALIBRATIONOne area of increasing relevance is that of field verification. Although the costand complexity of in-house calibration is too much for the average drinking water treatment...
  • 8
  • 430
  • 1
A Practical Guide to Particle Counting for Drinking Water Treatment - Chapter 18 ppt

A Practical Guide to Particle Counting for Drinking Water Treatment - Chapter 18 ppt

... 160 A PRACTICAL GUIDE TO PARTICLE COUNTING It is an advantage to be able to clean the flow cell without opening the NEMAenclosure, since water may be spilled into the enclosure. Chemtrac and ARTI ... E. ANALOG OUTPUTS Met One offers separate particle counter models for serial data and 4 to 20 mAoutput. The serial data model can provide 4 to 20 mA output data as well. Chemtrac,ARTI, and ... analoginputs can be configured to accept the signal. The analog input comes as a standardfeature and has the same input voltage range as the Chemtrac unit. C. ANALOG INPUTS All of the manufacturers...
  • 9
  • 963
  • 0
A Practical Guide to Particle Counting for Drinking Water Treatment - Chapter 21 pptx

A Practical Guide to Particle Counting for Drinking Water Treatment - Chapter 21 pptx

... most of the standard SCADA optomuxdrivers are incomplete and must be modified to accommodate it. Any of the manu-facturers may have developed an interface for a particular SCADA package, so itnever ... require a little more effort to clean and maintain, and a particular style of software presentation may be moresuited to a given set of operators. Although it is becoming less practical to haveeach ... important featuresnecessary to a well-run particle counting system. ARTI, Met One, and Chemtrac offer similar packages, with Aquarius and WQSbeing a little more up -to- date with multiple graphing...
  • 4
  • 263
  • 0
A Practical Guide to Particle Counting for Drinking Water Treatment - Chapter 1 potx

A Practical Guide to Particle Counting for Drinking Water Treatment - Chapter 1 potx

... Data Broadwell, Mike A practical guide to particle counting for drinking water treatment/ Mike Broadwell.p. cm.Includes index.ISBN 1-5 667 0-3 0 6-9 (alk. paper)1. Particle counting (Water treatment ... D.C. A Practical Guide to Mike Broadwell for Particle Counting Drinking Water Treatment © 2001 by CRC Press LLC 6 A PRACTICAL GUIDE TO PARTICLE COUNTING The second reason for preferring light-blocking ... comprehensive yet practical guide to understanding the technology of particle counting and its application to drinking water treatment a book that will be useful to the plant operator as well as theconsulting...
  • 28
  • 523
  • 1
A Practical Guide to Particle Counting for Drinking Water Treatment - Chapter 2 potx

A Practical Guide to Particle Counting for Drinking Water Treatment - Chapter 2 potx

... Packaged Treatment PlantsPackaged treatment plants, as touched on above, are prefabricated plants, whichare more cost-effective than ground-up plants for smaller applications. A packagedplant ... removal. (Courtesy of Pacific Scientific Instruments, Grants Pass, OR.)28 A PRACTICAL GUIDE TO PARTICLE COUNTING manufacturers of packaged treatment plants employ particle counters as a standardpart ... brieflyat some of the potential applications for particle counters in wastewater treatment. Standard wastewater is too high in concentration for particle counters, but special-L1306/frame/pt01 Page...
  • 16
  • 493
  • 1
A Practical Guide to Particle Counting for Drinking Water Treatment - Chapter 4 pot

A Practical Guide to Particle Counting for Drinking Water Treatment - Chapter 4 pot

... PRACTICAL GUIDE TO PARTICLE COUNTING The disadvantage to this approach is that the particle counter data are collectedand displayed separately from the other plant data, requiring separate training ... second alternative is the direct interface of the particle counters to SCADAusing serial data communications. All count data, as well as status and alarminformation, are transmitted in a specially ... developing a useful and practical approach to particle counting that can be tailored to the capabilities and resourcesof the individual drinking water treatment plant. None of the information presentedhere...
  • 11
  • 390
  • 0

Xem thêm

Từ khóa: intellectual property and open source a practical guide to protecting codea practical guide to solaris securitya practical guide to protecting codea practical guide to fedora and redhat enterprise linux fifth edition odd answersship it a practical guide to successful software projectsa practical guide to fedora and redhat enterprise linux odd answersBáo cáo thực tập tại nhà thuốc tại Thành phố Hồ Chí Minh năm 2018Nghiên cứu sự biến đổi một số cytokin ở bệnh nhân xơ cứng bì hệ thốngNghiên cứu tổ chức chạy tàu hàng cố định theo thời gian trên đường sắt việt namGiáo án Sinh học 11 bài 13: Thực hành phát hiện diệp lục và carôtenôitGiáo án Sinh học 11 bài 13: Thực hành phát hiện diệp lục và carôtenôitPhát triển mạng lưới kinh doanh nước sạch tại công ty TNHH một thành viên kinh doanh nước sạch quảng ninhPhát hiện xâm nhập dựa trên thuật toán k meansNghiên cứu khả năng đo năng lượng điện bằng hệ thu thập dữ liệu 16 kênh DEWE 5000Thơ nôm tứ tuyệt trào phúng hồ xuân hươngThiết kế và chế tạo mô hình biến tần (inverter) cho máy điều hòa không khíSở hữu ruộng đất và kinh tế nông nghiệp châu ôn (lạng sơn) nửa đầu thế kỷ XIXChuong 2 nhận dạng rui roQuản lý nợ xấu tại Agribank chi nhánh huyện Phù Yên, tỉnh Sơn La (Luận văn thạc sĩ)Tăng trưởng tín dụng hộ sản xuất nông nghiệp tại Ngân hàng Nông nghiệp và Phát triển nông thôn Việt Nam chi nhánh tỉnh Bắc Giang (Luận văn thạc sĩ)chuong 1 tong quan quan tri rui roGiáo án Sinh học 11 bài 14: Thực hành phát hiện hô hấp ở thực vậtGiáo án Sinh học 11 bài 14: Thực hành phát hiện hô hấp ở thực vậtTrách nhiệm của người sử dụng lao động đối với lao động nữ theo pháp luật lao động Việt Nam từ thực tiễn các khu công nghiệp tại thành phố Hồ Chí Minh (Luận văn thạc sĩ)Chiến lược marketing tại ngân hàng Agribank chi nhánh Sài Gòn từ 2013-2015MÔN TRUYỀN THÔNG MARKETING TÍCH HỢP